journal article·2022-02

Axial Behavior of Concrete Prisms Confined by FRP Laminate and Spike Anchors

Zhibin Li, Enrique del Rey Castillo, Richard S. Henry, Andrew Thompson

Publisher page

Abstract

Reinforced concrete (RC) buildings constructed before introducing ductile design requirements may exhibit undesirable seismic behavior. One such vulnerability is the lack of confinement to end regions that may lead to nonductile compression failures for RC walls. To overcome this vulnerability, strengthening nonductile RC walls is often required. The addition of confinement to end region concrete can be implemented using carbon fiber-reinforced polymer (FRP) laminate and spike anchors. The main issue encountered when applying this strengthening method is the lack of existing design guidance on this confinement method, due to a lack of experimental data to validate the approach. The objective of this study was to provide the necessary experimental data to quantify the behavior of concrete confined with FRP laminate and spike anchors. Static monotonic axial compression tests were conducted on 46 concrete prisms confined with FRP laminate and spike anchors and the other six unconfined concrete prisms. These prisms represented the end regions of RC walls. The variables investigated for the confined test prisms included anchor spacing, anchor cross-sectional area, and cross-sectional aspect ratio. It shows that peak strength increased significantly with the decrease of anchor spacing and the increase of anchor cross-sectional area. An increase in anchor cross-sectional area had a more considerable influence on the failure strain than a decrease in anchor spacing. The cross-sectional aspect ratio of the prisms had an insignificant impact on failure strain. When gross anchor cross-sectional area was constant in the confinement arrangement, larger peak strength, strain at peak, and failure strain were generally observed in prisms confined with smaller and more closely spaced anchors. Design recommendations were given on the test variables based on test results.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Ph.D. Candidate, Dept. of Civil and Environmental Engineering, Univ. of Auckland, Auckland 1010, New Zealand (corresponding author).

Lecturer, Dept. of Civil and Environmental Engineering, Univ. of Auckland, Auckland 1010, New Zealand. ORCID: .

Senior Lecturer, Dept. of Civil and Environmental Engineering, Univ. of Auckland, Auckland 1010, New Zealand.

Structural Engineer, Holmes Consulting (New Zealand), Auckland 1010, New Zealand.

References (51)

Show source-provided references
1. ACI (American Concrete Institute). 2017. Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures. ACI 440.2R. Farmington Hills, MI: ACI.
2. ACI (American Concrete Institute). 2019. Building code requirements for structural concrete. ACI 318-19. Farmington Hills, MI: ACI.
3. 10.1016/j.compositesb.2012.05.00910.1016/j.compositesb.2012.05.009 ↗
4. ASTM. 2017. Standard test method for tensile properties of polymer matrix composite materials. ASTM D3039. West Conshohocken, PA: ASTM.
5. 10.1007/s40069-013-0028-110.1007/s40069-013-0028-1 ↗
6. 10.3390/fib802001310.3390/fib8020013 ↗
7. 10.1016/j.engstruct.2012.06.03710.1016/j.engstruct.2012.06.037 ↗
8. 10.1061/(ASCE)CC.1943-5614.000009110.1061/(ASCE)CC.1943-5614.0000091 ↗
9. 10.1016/j.compstruct.2019.01.02410.1016/j.compstruct.2019.01.024 ↗
10. 10.1016/j.compstruct.2018.11.09110.1016/j.compstruct.2018.11.091 ↗
11. 10.1016/j.compstruct.2018.10.09310.1016/j.compstruct.2018.10.093 ↗
12. 10.1016/j.compstruct.2018.07.02910.1016/j.compstruct.2018.07.029 ↗
13. 10.1016/j.compstruct.2018.09.07310.1016/j.compstruct.2018.09.073 ↗
14. 10.1061/(ASCE)CC.1943-5614.000109510.1061/(ASCE)CC.1943-5614.0001095 ↗
15. del Rey Castillo E. R. Kanitkar and S. Smith. 2019e. “Case studies of using FRP anchors in New Zealand.” In Proc. 7th Asia-Pacific Conf. on FRP in Structures 1–5. Chennai India: IIFC.
16. del Rey Castillo, E., R. Kanitkar, S. Smith, M. Griffith, and J. Ingham. 2019f. “Fan-to-sheet failure mode of FRP anchors.” In Proc., FRPRCS-14 Symp.: The 14th Int. Symp. on Fiber-Reinforced for Concrete Structure. Belfast, Northern Ireland: Queen's University.
17. 10.1016/j.compstruct.2019.01.10010.1016/j.compstruct.2019.01.100 ↗
18. 10.1061/(ASCE)CC.1943-5614.000031210.1061/(ASCE)CC.1943-5614.0000312 ↗
19. 10.1680/macr.1982.34.121.19110.1680/macr.1982.34.121.191 ↗
20. 10.1007/s40069-013-0029-010.1007/s40069-013-0029-0 ↗
21. 10.1016/j.engstruct.2018.12.05610.1016/j.engstruct.2018.12.056 ↗
22. 10.1016/j.compstruct.2016.08.01010.1016/j.compstruct.2016.08.010 ↗
23. 10.1061/(ASCE)CC.1943-5614.000027610.1061/(ASCE)CC.1943-5614.0000276 ↗
24. 10.1002/suco.20110004410.1002/suco.201100044 ↗
25. Kanitkar, R., E. del Rey Castillo, S. Smith, and H. Rasheed. 2019. “Quality control and assurance for FRP anchors-current practice and path forward.” In Proc., 7th Asia-Pacific Conf. on FRP in Structures, 1–5. ON, Canada: IIFC.
26. Karayannis, C. G., and E. Golias. 2018. “Full scale tests of RC joints with minor to moderate seismic damage repaired using C-FRP sheets.” Earthquakes Struct. 15 (6): 617–627. https://doi.org/10.12989/eas.2018.15.6.617.
27. 10.1080/1363246050935054710.1080/13632460509350547 ↗
28. Kobayashi, K. 2005. “Innovative application of FRPs for seismic strengthening of RC shear wall.” In Fiber-Reinforced Polymer (FRP) Reinforcement for Concrete Structures, 1269–1288. ON, Canada: IIFC.
29. 10.1177/073168440303542910.1177/0731684403035429 ↗
30. 10.1061/(ASCE)ST.1943-541X.000172310.1061/(ASCE)ST.1943-541X.0001723 ↗
31. MATLAB. 2015. MATLAB and statistics toolbox release 2015. Natick, MA: MathWorks.
32. 10.20965/jdr.2014.p100810.20965/jdr.2014.p1008 ↗
33. Matsui, T., T. Saito, and R. Reyna. 2017. “Structural performance of rectangular reinforced concrete walls retrofitted by carbon fiber sheets.” In Proc., 16th World Conf. on Earthquake Engineering, 9–13. Red Hook, NY: Curran Associates.
34. 10.1016/j.compstruct.2015.12.02010.1016/j.compstruct.2015.12.020 ↗
35. 10.1016/j.conbuildmat.2020.11811110.1016/j.conbuildmat.2020.118111 ↗
36. 10.1016/j.compstruct.2018.11.02410.1016/j.compstruct.2018.11.024 ↗
37. 10.1061/(ASCE)CC.1943-5614.000006410.1061/(ASCE)CC.1943-5614.0000064 ↗
38. NZS (New Zealand Standards). 1986. Methods of test for concrete—Tests relating to the determination of strength of concrete. NZS 3112.2. Wellington, New Zealand: NZS.
39. NZS (New Zealand Standards). 2006. Concrete structures standard. NZS 3101. Wellington, New Zealand: NZS.
40. 10.1061/(ASCE)1090-0268(2008)12:6(608)10.1061/(ASCE)1090-0268(2008)12:6(608) ↗
41. 10.1002/978047017284110.1002/9780470172841 ↗
42. 10.1061/(ASCE)CC.1943-5614.000020810.1061/(ASCE)CC.1943-5614.0000208 ↗
43. 10.1016/j.compstruct.2015.03.05110.1016/j.compstruct.2015.03.051 ↗
44. 10.1061/(ASCE)1090-0268(2008)12:1(80)10.1061/(ASCE)1090-0268(2008)12:1(80) ↗
45. 10.1142/9789812704863_002510.1142/9789812704863_0025 ↗
46. 10.5459/bnzsee.53.2.54-6910.5459/bnzsee.53.2.54-69 ↗
47. 10.1193/021713EQS036M10.1193/021713EQS036M ↗
48. Stubbing, R. M. 2016. DTA report 408/NR 1690-digital image correlation capability. Auckland, New Zealand: Defence Technology Agency (DTA), New Zealand Defence Force.
49. 10.1016/j.compstruct.2016.10.09610.1016/j.compstruct.2016.10.096 ↗
50. Zhang, T., K. Elwood, and R. Henry. 2018. “Testing of singly reinforced concrete walls used in existing buildings.” In Proc., 2018 NZSEE Annual Conf. Auckland, New Zealand: New Zealand Society for Earthquake Engineering (NZSEE).
51. 10.1016/j.conbuildmat.2021.12297510.1016/j.conbuildmat.2021.122975 ↗