journal article·2022-06

Bond Behavior of Straight and Bent Glass Fiber–Reinforced Polymer Bars at Elevated Temperatures: Pull-Out Tests and Numerical Simulations

Inês C. Rosa, Mário R. T. Arruda, João P. Firmo, João R. Correia

Publisher page

Abstract

The bond between concrete and fiber-reinforced polymer (FRP) bars is severely degraded when the glass transition temperature of the FRP (set mainly by the polymeric matrix, typically a thermosetting resin) is approached, and therefore long development lengths are required to enable a proper anchorage in cooler zones of FRP–reinforced concrete (RC) members exposed to fire. In spite of the potential of bent bars to shorten such lengths, and thereby improve the fire resistance of FRP–RC members, very few studies have addressed the effects of elevated temperatures on the bond performance of bent FRP reinforcement. This paper presents experimental and numerical investigations concerning the bond behavior of straight and 90°-bent glass-FRP (GFRP) bars at elevated temperatures. Steady-state pull-out tests were first carried out on bent ribbed bars, from 20°C up to 300°C, and the results were compared with those previously obtained from straight bars. The experiments showed that the hook effect provided by the bend and tail lengths of the bars enabled bond-strength increases of between 30% and 90% compared with straight bars. Three-dimensional finite-element models were then developed to: (1) simulate the pull-out tests; and (2) perform design-oriented parametric studies, aimed at assessing the influence of elevated temperatures on the anchorage strength of straight bars with different surface finishes (sand-coated and ribbed), and of 90°-bent ribbed bars with varying tail and straight development lengths. Temperature-dependent local bond stress versus slip laws were implemented in the models in order to describe the bond interaction along the straight and bent lengths of the bars. The models provided a good agreement with the test data, in terms of load versus slip response, and a reduction in pull-out load and bond stiffness with temperature. The findings were that: (1) the adoption of 90°-bent anchorages with appropriate tail lengths is an effective and practical approach for improving the bond strength of GFRP bars at both ambient and elevated temperatures; and (2) at elevated temperatures, to mobilize the tensile strength of GFRP bars, the development lengths of straight and bent bars designed for ambient temperature must be significantly increased. Finally, optimal anchorage lengths are proposed, as a function of temperature, for beam and slab applications.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Fire effects on concrete materials · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Ph.D. Candidate, CERIS, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais 1, 1049-001 Lisboa, Portugal (corresponding author). ORCID: .

Research Fellow, CERIS, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais 1, 1049-001 Lisboa, Portugal. ORCID: .

Research Fellow, CERIS, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais 1, 1049-001 Lisboa, Portugal.

Full Professor, CERIS, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais 1, 1049-001 Lisboa, Portugal.

References (40)

Show source-provided references
1. 10.1016/j.compositesa.2005.05.02910.1016/j.compositesa.2005.05.029 ↗
2. ACI (American Concrete Institute). 2011. Building code requirements for structural concrete. ACI 318-11. Farmington Hills, MI: ACI.
3. ACI (American Concrete Institute). 2015. Guide for the design and construction of structural concrete reinforced with FRP bars. ACI 440.1R-15. Farmington Hills, MI: ACI.
4. 10.1061/(ASCE)CC.1943-5614.000065610.1061/(ASCE)CC.1943-5614.0000656 ↗
5. ASTM. 2014. Standard test method for bond strength of fiber-reinforced polymer matrix composite bars to concrete by pullout testing. ASTM D7913/D7913M-14. West Conshohocken, PA: ASTM.
6. 10.1061/(ASCE)0733-9445(1988)114:11(2493)10.1061/(ASCE)0733-9445(1988)114:11(2493) ↗
7. 10.1139/l04-04910.1139/l04-049 ↗
8. 10.1016/j.engstruct.2020.11105810.1016/j.engstruct.2020.111058 ↗
9. 10.1016/j.compositesb.2013.05.01310.1016/j.compositesb.2013.05.013 ↗
10. CEN (European Committee for Standardization). 2009a. Testing hardened concrete - part 3: Compressive strength of test specimens. EN 12390-3. Brussels, Belgium: CEN.
11. CEN (European Committee for Standardization). 2009b. Testing hardened concrete - part 6: Tensile splitting strength of test specimens. EN 12390-6. Brussels, Belgium: CEN.
12. CEN (European Committee for Standardization). 2010a. Design of concrete structures - part 1-2: General rules - Structural fire design. Eurocode 2. EN 1992-1-2. Brussels, Belgium: CEN.
13. CEN (European Committee for Standardization). 2010b. Design of concrete structures - part 1-1: General rules and rules for buildings. Eurocode 2. EN 1992-1-1. Brussels, Belgium: CEN.
14. 10.1016/j.compstruct.2016.04.04810.1016/j.compstruct.2016.04.048 ↗
15. FIB (International Federation for Structural Concrete). 2007. FRP reinforcement for RC structures. Bulletin 40. Lausanne, Switzerland: FIB.
16. 10.1061/(ASCE)CC.1943-5614.000089710.1061/(ASCE)CC.1943-5614.0000897 ↗
17. 10.1061/(ASCE)CC.1943-5614.000093710.1061/(ASCE)CC.1943-5614.0000937 ↗
18. 10.1007/BF0002085310.1007/BF00020853 ↗
19. ISO. 1996. Textile-glass-reinforced plastics - Prepregs, moulding compounds and laminates - Determination of the textile-glass and mineral-filler content - Calcination methods. ISO 1172. Geneva: ISO.
20. 10.1061/(ASCE)1090-0268(1999)3:2(73)10.1061/(ASCE)1090-0268(1999)3:2(73) ↗
21. Kiari, M., T. Stratford, and L. A. Bisby. 2015. “New design of beam FRP reinforcement for fire performance.” In Proc., 5th Int. Workshop on Performance, Protection & Strengthening of Structures under Extreme Loading, edited by Venkatesh K. R. Kodur, and N. Banthia, 764–771. Lancaster, PA: DEStech Publications, Inc.
22. Kiari, M., T. J. Stratford, and L. A. Bisby. 2016. “New approach to fire safe application of fibre-reinforced polymer reinforcement for concrete.” In Proc., 7th Int. Conf. on Advanced Composite Materials in Bridges and Structures. Vancouver, BC: University of British Columbia.
23. Kiari, M., E. Triantafyllidou, S. Grosu, T. Stratford, and L. Bisby. 2013. “Design of an FRP-reinforced concrete beam system for fire performance.” In Advanced Composites in Construction 2013, edited by C. J. Whysall, and S. E. Taylor, 145–154. Chesterfield, UK: NetComposites Limited.
24. Lopes, B., M. R. T. Arruda, L. Almeida-Fernandes, L. Castro, N. Silvestre, and J. R. Correia. 2020. “Assessment of mesh dependency in the numerical simulation of compact tension tests for orthotropic materials.” Composites, Part C 1: 100006. https://doi.org/10.1016/j.jcomc.2020.100006.
25. McIntyre E. 2019. “Fire performance of fibre reinforced polymer (FRP) bars in reinforced concrete: An experimental approach.” Ph.D. thesis Dept. of Civil Engineering Univ. of Edinburgh.
26. Mouritz A. P. and A. G. Gibson. 2006. Fire properties of polymer composite materials. Solid mechanics and its applications. Birkhauser Switzerland: Springer.
27. 10.1061/(ASCE)CC.1943-5614.000027910.1061/(ASCE)CC.1943-5614.0000279 ↗
28. 10.1016/j.compositesb.2018.10.02010.1016/j.compositesb.2018.10.020 ↗
29. 10.1016/j.cemconcomp.2021.10411910.1016/j.cemconcomp.2021.104119 ↗
30. 10.1061/(ASCE)CC.1943-5614.000083910.1061/(ASCE)CC.1943-5614.0000839 ↗
31. 10.1016/j.compstruct.2020.11227010.1016/j.compstruct.2020.112270 ↗
32. Schöck. 2013. “Schöck ComBAR - Technical information.” Technical datasheet.
33. 10.1016/j.compstruc.2004.03.04710.1016/j.compstruc.2004.03.047 ↗
34. Sena-Cruz J. M. 2005. “Strengthening of concrete structures with near-surface mounted CFRP laminate strips.” Ph.D. thesis Dept. of Civil Engineering Universidade do Minho.10.1016/S0045-7949(04)00137-3 ↗
35. SIMULIA. 2018. ABAQUS standard user’s manual version 2018. Johnston RI: Dassault Systèmes.
36. 10.1016/j.compositesb.2019.10760210.1016/j.compositesb.2019.107602 ↗
37. 10.1016/0958-9465(92)90007-I10.1016/0958-9465(92)90007-I ↗
38. 10.2749/guimaraes.2019.106510.2749/guimaraes.2019.1065 ↗
39. Weber, A. 2008. “Fire-resistance tests on composite rebars.” In Proc., 4th Int. Conf. of FRP Composites in Civil Engineering. Lausanne, Switzerland: Swiss Federal Institute of Technology (EPFL).
40. Yuan, J. S., and M. N. S. Hadi. 2018. “Friction coefficient between FRP pultruded profiles and concrete.” Mater. Struct. 51 (120): 1–10.