journal article·2023-04Open access

Compressive Behavior of Concrete-Filled Filament-Wound FRP Tubes with Local Tube Damage

Guan Lin, Yu Xiang

Abstract

Concrete-filled fiber-reinforced polymer (FRP) tubes (CFFTs) are an emerging and attractive form of column for new constructions. Such a column consists of outer filament-wound FRP tubes that are filled with plain or steel-reinforced concrete. The fibers in the filament-wound FRP tube are predominantly in the hoop direction to confine the inner concrete, which leads to significantly enhanced strength and ductility in the confined concrete. Extensive studies have been conducted on the behavior of CFFTs that were subjected to various loading conditions, which confirmed the excellent performance of such members. As CFFTs become increasingly used in practice, there is a concern about the performance of CFFTs when the FRP tube is subjected to local damage that is caused by accidents, vandalism, or designed holes or cuts to accommodate connections with other structural components. Some studies have been carried out on the performance of CFFTs as flexural members with a locally damaged filament-wound FRP tube; however, the research on such CFFTs as columns remains limited. This paper presented the results of a comprehensive experimental program on the axial compressive behavior of CFFTs with a filament-wound FRP tube that was subjected to local tube damage. Two types of damage (i.e., holes and cuts) with different parameters were investigated. The test results showed that the compressive strength [i.e., peak stress ( fcc′)] and the corresponding axial strain (ɛcc) of the damaged CFFTs were significantly reduced due to the local tube damage (e.g., fcc′ reduced from 12.2% to 64.8% and the corresponding ɛcc reduced from 35.2% to 77.2%). Finally, an existing model for FRP-confined concrete that considered the local FRP damage was evaluated which suggested the need for the recalibration of the model or the development of a new model for CFFTs with a locally damaged filament-wound FRP tube.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Associate Professor, Dept. of Ocean Science and Engineering, Southern Univ. of Science and Technology, Shenzhen, Guangdong 518055, China; Former Research Assistant Professor, Dept. of Civil and Environmental Engineering, The Hong Kong Polytechnic Univ., Hong Kong, China.

Research Assistant Professor, Dept. of Civil and Environmental Engineering, The Hong Kong Polytechnic Univ., Hong Kong, China (corresponding author). ORCID: .

References (39)

Show source-provided references
1. AASHTO. 2012. LRFD guide specifications for design of concrete-filled FRP tubes for flexural and axial members. 1st ed. Washington, DC: AASHTO.
2. ACI (American Concrete Institute). 2017. Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures. ACI 440.2R. Farmington Hills, MI: ACI.
3. Adheem, A. H., M. M. A. Kadhim, A. Jawdhari, and A. Fam. 2021. “Confinement model for concrete wrapped with fiber reinforced cementitious mortar.” Constr. Build. Mater. 312: 125401. https://doi.org/10.1016/j.conbuildmat.2021.125401.10.1016/j.conbuildmat.2021.125401 ↗
4. ASTM. 2019. Standard test method for apparent hoop tensile strength of plastic or reinforced plastic pipe by split disk method. ASTM D2290. West Conshohocken, PA: ASTM.
5. ASTM. 2022. Standard test method for static modulus of elasticity and Poisson’s ratio of concrete in compression. ASTM C469. West Conshohocken, PA: ASTM.
6. Burgueño, R., and K. M. Bhide. 2006. “Shear response of concrete-filled FRP composite cylindrical shells.” J. Struct. Eng. 132 (6): 949–960. https://doi.org/10.1061/(ASCE)0733-9445(2006)132:6(949).10.1061/(ASCE)0733-9445(2006)132:6(949) ↗
7. Dong, Z., T. Han, B. Zhang, H. Zhu, G. Wu, Y. Wei, and P. Zhang. 2021. “A review of the research and application progress of new types of concrete-filled FRP tubular members.” Constr. Build. Mater. 312: 125353. https://doi.org/10.1016/j.conbuildmat.2021.125353.10.1016/j.conbuildmat.2021.125353 ↗
8. Echevarria, A., A. Zaghi, R. Christenson, and R. Plank. 2015. “Residual axial capacity comparison of CFFT and RC bridge columns after fire.” Polymers 7 (5): 876–895. https://doi.org/10.3390/polym7050876.10.3390/polym7050876 ↗
9. ElGawady, M. A., and H. M. Dawood. 2012. “Analysis of segmental piers consisted of concrete filled FRP tubes.” Eng. Struct. 38: 142–152. https://doi.org/10.1016/j.engstruct.2012.01.001.10.1016/j.engstruct.2012.01.001 ↗
10. El-Zefzafy, H., H. M. Mohamed, and R. Masmoudi. 2013. “Evaluation effects of the short-and long-term freeze-thaw exposure on the axial behavior of concrete-filled glass fiber-reinforced-polymer tubes.” J. Compos. 2013: 340672. https://doi.org/10.1155/2013/340672.10.1155/2013/340672 ↗
11. Fam, A., R. Greene, and S. Rizkalla. 2003a. “Field applications of concrete-filled FRP tubes for marine piles.” Spec. Publ. 215: 161–180.
12. Fam, A., M. Pando, G. Filz, and S. Rizkalla. 2003b. “Precast piles for route 40 bridge in Virginia using concrete filled FRP tubes.” PCI J. 48 (3): 32–45. https://doi.org/10.15554/pcij.05012003.32.45.10.15554/pcij.05012003.32.45 ↗
13. Fam, A. Z., and S. H. Rizkalla. 2001a. “Behavior of axially loaded concrete-filled circular fiber-reinforced polymer tubes.” ACI Struct. J. 98 (3): 280–289.
14. Fam, A. Z., and S. H. Rizkalla. 2001b. “Confinement model for axially loaded concrete confined by circular fiber-reinforced polymer tubes.” ACI Struct. J. 98 (4): 451–461.
15. Gholampour, A., and T. Ozbakkaloglu. 2018. “Behavior of steel fiber-reinforced concrete-filled FRP tube columns: Experimental results and a finite element model.” Compos. Struct. 194: 252–262. https://doi.org/10.1016/j.compstruct.2018.03.094.10.1016/j.compstruct.2018.03.094 ↗
16. Hassanli, R., O. Youssf, T. Vincent, J. E. Mills, A. Manalo, and R. Gravina. 2020. “Experimental study on compressive behavior of FRP-confined expansive rubberized concrete.” J. Compos. Constr. 24 (4): 04020034. https://doi.org/10.1061/(ASCE)CC.1943-5614.0001038.10.1061/(ASCE)CC.1943-5614.0001038 ↗
17. Jawdhari, A., A. Fam, and M. Noël. 2021a. “Design equation for concrete-filled FRP tubes in flexure including damage effects.” Eng. Struct. 239: 112267. https://doi.org/10.1016/j.engstruct.2021.112267.10.1016/j.engstruct.2021.112267 ↗
18. Jawdhari, A., A. Fam, and P. Sadeghian. 2020. “Modeling the nonlinear response of ±55 angle-ply GFRP tube used in CFFT applications.” In Proc., 8th Int. Conf., on Advanced Composite Materials in Bridges and Structures, edited by B. Benmokrane, K. Mohamed, A. Farghaly, and H. Mohamed, 413–421. Cham, Switzerland: Springer.
19. Jawdhari, A., A. Hadhood, and A. Fam. 2021b. “Confinement model for FRP-wrapped circular columns when the wraps are subjected to damage.” Constr. Build. Mater. 275: 122101. https://doi.org/10.1016/j.conbuildmat.2020.122101.10.1016/j.conbuildmat.2020.122101 ↗
20. Ji, G., G. Li, X. Li, S. S. Pang, and R. Jones. 2008. “Experimental study of FRP tube encased concrete cylinders exposed to fire.” Compos. Struct. 85 (2): 149–154. https://doi.org/10.1016/j.compstruct.2007.10.013.10.1016/j.compstruct.2007.10.013 ↗
21. Lu, C., and A. Fam. 2020. “The effect of tube damage on flexural strength of ±55° angle-ply concrete-filled FRP tubes.” Constr. Build. Mater. 240: 117948. https://doi.org/10.1016/j.conbuildmat.2019.117948.10.1016/j.conbuildmat.2019.117948 ↗
22. Lu, C., J. St. Onge, and A. Fam. 2020. “Damage threshold of near-cross-ply tubes used in concrete-filled FRP tubes loaded in flexure.” J. Compos. Constr. 24 (2): 04019063. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000990.10.1061/(ASCE)CC.1943-5614.0000990 ↗
23. Mirmiran, A., and M. Shahawy. 1997. “Behavior of concrete columns confined by fiber composites.” J. Struct. Eng. 123 (5): 583–590. https://doi.org/10.1061/(ASCE)0733-9445(1997)123:5(583).10.1061/(ASCE)0733-9445(1997)123:5(583) ↗
24. Ozbakkaloglu, T., and D. J. Oehlers. 2008. “Concrete-filled square and rectangular FRP tubes under axial compression.” J. Compos. Constr. 12 (4): 469–477. https://doi.org/10.1061/(ASCE)1090-0268(2008)12:4(469).10.1061/(ASCE)1090-0268(2008)12:4(469) ↗
25. Qasrawi, Y., P. J. Heffernan, and A. Fam. 2015. “Performance of concrete-filled FRP tubes under field close-in blast loading.” J. Compos. Constr. 19 (4): 04014067. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000502.10.1061/(ASCE)CC.1943-5614.0000502 ↗
26. Robert, M., and A. Fam. 2012. “Long-term performance of GFRP tubes filled with concrete and subjected to salt solution.” J. Compos. Constr. 16 (2): 217–224. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000251.10.1061/(ASCE)CC.1943-5614.0000251 ↗
27. Rodsin, K., Q. Hussain, S. Suparp, and A. Nawaz. 2020. “Compressive behavior of extremely low strength concrete confined with low-cost glass FRP composites.” Case Stud. Constr. Mater. 13: e00452. https://doi.org/10.1016/j.cscm.2020.e00452.
28. Shi, Y., B. Li, and A. Mirmiran. 2011. “Combined shear and flexural behavior of hybrid FRP-concrete beams previously subjected to cyclic loading.” J. Compos. Constr. 15 (5): 841–849. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000202.10.1061/(ASCE)CC.1943-5614.0000202 ↗
29. Taveras, O., A. Fam, A. Hadhood, and B.-K. Song. 2022. “Experimental investigation of axial strength of damaged concrete-filled FRP tubes.” Structures 44: 1783–1796. https://doi.org/10.1016/j.istruc.2022.08.111.10.1016/j.istruc.2022.08.111 ↗
30. Teng, J. G., T. Yu, Y. L. Wong, and S. L. Dong. 2007. “Hybrid FRP-concrete-steel tubular columns: Concept and behavior.” Constr. Build. Mater. 21 (4): 846–854. https://doi.org/10.1016/j.conbuildmat.2006.06.017.10.1016/j.conbuildmat.2006.06.017 ↗
31. Tijani, I. A., C. Jiang, C. Lim, and Y. F. Wu. 2020. “Effect of load eccentricity on the mechanical response of FRP-confined predamaged concrete under compression.” J. Compos. Constr. 24 (5): 04020057. https://doi.org/10.1061/(ASCE)CC.1943-5614.0001071.10.1061/(ASCE)CC.1943-5614.0001071 ↗
32. Vincent, T., and T. Ozbakkaloglu. 2013. “Influence of fiber orientation and specimen end condition on axial compressive behavior of FRP-confined concrete.” Constr. Build. Mater. 47: 814–826. https://doi.org/10.1016/j.conbuildmat.2013.05.085.10.1016/j.conbuildmat.2013.05.085 ↗
33. Wang, S., and M. A. ElGawady. 2020. “Performance of concrete-filled fiber-reinforced polymer tube stubs subjected to sustained axial load and long-term seawater corrosion.” ACI Mater. J. 117 (5): 13–26. https://doi.org/10.1016/j.actamat.2020.04.033.
34. Yu, T., and J. G. Teng. 2011. “Design of concrete-filled FRP tubular columns: Provisions in the Chinese technical code for infrastructure application of FRP composites.” J. Compos. Constr. 15 (3): 451–461. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000159.10.1061/(ASCE)CC.1943-5614.0000159 ↗
35. Yu, T., B. Zhang, and J. G. Teng. 2015. “Unified cyclic stress–strain model for Normal and high strength concrete confined with FRP.” Eng. Struct. 102: 189–201. https://doi.org/10.1016/j.engstruct.2015.08.014.10.1016/j.engstruct.2015.08.014 ↗
36. Zhang, B., J. G. Teng, and T. Yu. 2017. “Compressive behavior of double-skin tubular columns with high-strength concrete and a filament-wound FRP tube.” J. Compos. Constr. 21 (5): 04017029. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000800.10.1061/(ASCE)CC.1943-5614.0000800 ↗
37. Zhang, B., T. Yu, and J. G. Teng. 2015. “Behavior of concrete-filled FRP tubes under cyclic axial compression.” J. Compos. Constr. 19 (3): 04014060. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000523.10.1061/(ASCE)CC.1943-5614.0000523 ↗
38. Zhu, Z., I. Ahmad, and A. Mirmiran. 2006. “Fiber element modeling for seismic performance of bridge columns made of concrete-filled FRP tubes.” Eng. Struct. 28 (14): 2023–2035. https://doi.org/10.1016/j.engstruct.2006.03.031.10.1016/j.engstruct.2006.03.031 ↗
39. Zohrevand, P., and A. Mirmiran. 2013. “Seismic response of ultra-high performance concrete-filled FRP tube columns.” J. Earthquake Eng. 17 (1): 155–170. https://doi.org/10.1080/13632469.2012.713560.10.1080/13632469.2012.713560 ↗