journal article·2021-10

Structural Performance of Concrete-Filled GFRP Tube Slender Columns in Ambient and Standard Fire Conditions

Kevin M. Barber, Osama “Sam” Salem, Amir Fam

Publisher page

Abstract

Concrete-filled glass fiber-reinforced polymer (GFRP) tube (CFFT) columns benefit from significant concrete confinement effects that enhance its structural performance compared to conventional internally reinforced concrete members. CFFTs are currently utilized mostly for exterior applications, as the uncertainty of their performance in fire situations has slowed their adaptation in buildings. To address this uncertainty, a series of ambient temperature and fire tests were conducted on CFFT columns with slenderness ratios (KL/r) ranging from 6.9 to 62.4, using GFRP tubes of 113 mm outer diameter and 3.8 mm wall thickness. The strength increase provided by the GFRP tubes as compared to plain concrete columns was reduced from the initial 214% increase at a KL/r of 6.9 to 104% at a KL/r of 62.4. The fire tests revealed that unprotected CFFT columns with KL/r = 57.4 were able to sustain the applied design service loads (44% of ultimate capacity) for up to 108 min in a standard fire. However, it was determined that the unprotected GFRP tubes lost their structural integrity after approximately 10 min of fire exposure, when the temperature on the inside of the tube reached 350°C, thereby only providing thermal protection to the concrete core after the 10-min mark. The unique outcomes of this new study indicate that CFFT columns can be a viable design option in fire situations.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Fire effects on concrete materials · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

M.Sc. Graduate, Dept. of Civil Eng., Lakehead Univ., Thunder Bay, ON, Canada P7B 5E1. ORCID: .

Associate Professor, Dept. of Civil Eng., Lakehead Univ., Thunder Bay, ON, Canada P7B 5E1 (corresponding author). ORCID: .

Professor, Dept. of Civil Eng., Queen’s Univ., Kingston, ON, Canada K7L 3N6.

References (27)

Show source-provided references
1. AASHTO. 2012. AASHTO LRFD guide specifications for design of concrete-filled FRP tubes for flexural and axial members. Washington, DC: AASHTO.
2. ACI (American Concrete Institute). 2017. Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures. ACI Committee 440. Farmington Hills, MI: ACI.
3. ASTM. 2020a. Standard test method for compressive strength of cylindrical concrete specimens. ASTM C39/C39M-20. West Conshohocken, PA: ASTM.
4. ASTM. 2020b. Standard test methods for fire tests of building construction and materials. ASTM E119-20. West Conshohocken, PA: ASTM.
5. Bisby, L., V. K. R. Kodur, and M. Green. 2005. “Fire endurance of fiber-reinforced polymer-confined concrete columns.” ACI Struct. J. 102 (6): 883–891.
6. 10.1016/j.firesaf.2006.10.00710.1016/j.firesaf.2006.10.007 ↗
7. 10.1016/j.firesaf.2012.08.00610.1016/j.firesaf.2012.08.006 ↗
8. CSA (Canadian Standards Association). 2015. Design of concrete structures. CSA A23.3-14. Rexdale, ON, Canada: CSA.
9. Doğan, G., and M. H. Arslan. 2016. “Failure modes of RC columns under loading.” Int. J. Sci. Eng. Res. 7 (12): 1279–1300.
10. 10.1201/b17063-22510.1201/b17063-225 ↗
11. 10.3390/polym705087610.3390/polym7050876 ↗
12. Fam, A., R. Greene, and S. Rizkalla. 2002. “Field applications of concrete-filled FRP tubes for marine piles.” In Field application of FRP reinforcement: Case studies, ACI Special Publication 215, edited by S. Rizkalla and A. Nanni, 161–180. Farmington Hills, MI: ACI.
13. 10.15554/pcij.05012003.32.4510.15554/pcij.05012003.32.45 ↗
14. Fam, A., and S. Rizkalla. 2001. “Behavior of axially loaded concrete-filled circular fiber-reinforced polymer tubes.” ACI Struct. J. 98 (3): 280–289.
15. 10.1061/(ASCE)1090-0268(2002)6:2(123)10.1061/(ASCE)1090-0268(2002)6:2(123) ↗
16. 10.1016/j.cemconcomp.2006.07.00810.1016/j.cemconcomp.2006.07.008 ↗
17. IMO (International Maritime Organization). 1993. Guidelines for the application of plastic pipe on ships. IMO Resolution A.753. London: IMO.
18. 10.1016/j.compstruct.2007.10.01310.1016/j.compstruct.2007.10.013 ↗
19. 10.1177/002199830934531410.1177/0021998309345314 ↗
20. 10.1177/104239150706195610.1177/1042391507061956 ↗
21. 10.1016/j.conbuildmat.2019.11794810.1016/j.conbuildmat.2019.117948 ↗
22. 10.1061/(ASCE)CC.1943-5614.000099010.1061/(ASCE)CC.1943-5614.0000990 ↗
23. 10.1061/(ASCE)1090-0268(2001)5:1(26)10.1061/(ASCE)1090-0268(2001)5:1(26) ↗
24. 10.1061/(ASCE)CC.1943-5614.000050210.1061/(ASCE)CC.1943-5614.0000502 ↗
25. 10.1016/j.engstruct.2015.06.01210.1016/j.engstruct.2015.06.012 ↗
26. 10.1016/S0263-8223(02)00045-410.1016/S0263-8223(02)00045-4 ↗
27. ULC (Underwriters’ Laboratories of Canada). 2014. Standard methods of fire endurance tests of building construction and materials. CAN/ULC-S101. Scarborough, ON: ULC.