journal article·2025-06

Experimental Study on the Bond Behavior of the CFRP Bar–UHPC Interface in Composite Anchorage

Jiaxing Chen, Zhi Fang, Wenchang Fang, Qiwu Wang, Xingyu Tan

Publisher page

Abstract

The bond performance at the interface between carbon-fiber-reinforced polymer (CFRP) bar and ultrahigh-performance concrete (UHPC) in composite anchorage was experimentally studied, and a suitable bar surface configuration was proposed. Pullout testing was performed on 36 specimens to evaluate the influence of surface treatment and anchorage length. Based on the results of the tensile testing, a formula for predicting the material properties of CFRP bar was proposed. Bar pullout is caused by the shearing off of the surface treatments, and the rupture is governed by the breaking load of the CFRP bar. The average bond strength improved with the increase in the depth–spacing ratio of rib, and decreased with the increase in anchorage length. The effect of the depth–spacing ratio on average bond strength was more remarkable in the specimens with a longer bonded length. The average bond strengths of smooth specimens were 13%–17% of that of the indented specimens. Additionally, the rib depth, groove width, rib spacing, and rib width were recommended as 0.03, 0.6, 1–1.2, and 0.4–0.6 times the bar diameter, respectively. Finally, formulas for calculating the average bond strength and critical anchorage length of the CFRP bar in the composite anchorage using UHPC as the bond medium were proposed.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Hunan Univ.

Hunan Univ., Key Laboratory for Wind and Bridge Engineering of Hunan Province

References (28)

Show source-provided references
1. ACI (American Concrete Institute). 2022. Building code requirements for structural concrete reinforced with GFRP bars—Code and commentary. ACI CODE 440.11-22. Farmington Hills, MI: ACI.
2. ASTM. 2021. Standard test method for tensile properties of fiber reinforced polymer matrix composite bars. ASTM D7205/D7205M-21. West Conshohocken, PA: ASTM.
3. 10.1016/j.compositesb.2009.07.00310.1016/j.compositesb.2009.07.003 ↗
4. 10.1061/(ASCE)1090-0268(1997)1:2(40)10.1061/(ASCE)1090-0268(1997)1:2(40) ↗
5. CSA (Canadian Standards Association). 2012. Design and construction of building structures with fiber-reinforced polymers. CSA S806-12. Rexdale, ON, Canada: CSA.
6. Eligehausen R. E. P. Popov and V. V. Bertero. 1983. Local bond stress-slip relationships of deformed bars under generalized excitations. Rep. No. 83/23. Berkeley CA: Earthquake Engineering Research Center.
7. 10.1061/(ASCE)CC.1943-5614.000035910.1061/(ASCE)CC.1943-5614.0000359 ↗
8. Fang, Z., C. Fang, Z. W. Jiang, Z. W. Wang, J. Y. Li, and Y. Q. Zhang. 2021. “Mechanical properties of CFRP bar and bond-type anchorage system after elevated temperature exposure.” [In Chinese.] Acta Materiae Compositae Sin. 38 (12): 4031–4041.
9. Gao, D. Y., H. T. Zhu, and J. J. Xie. 2003. “The constitutive models for bond slip relation between FRP rebars and concrete.” [In Chinese.] Ind. Constr. 33 (7): 41–43.
10. Hao, Q. D., Y. L. Wang, J. L. Hou, and J. P. Ou. 2008. “Experimental study on bond behavior of GFRP ribbed rebars.” [In Chinese.] Eng. Mech. 25 (10): 158–165+179.
11. 10.1016/j.jobe.2017.02.00510.1016/j.jobe.2017.02.005 ↗
12. 10.1016/j.conbuildmat.2020.12065410.1016/j.conbuildmat.2020.120654 ↗
13. Jiang T. Y. 2008. “Experimental and theoretical investigation on the anchorage system for CFRP tendons.” Ph.D. thesis College of Civil Engineering Univ. of Hunan.
14. 10.1016/j.compstruct.2022.11553310.1016/j.compstruct.2022.115533 ↗
15. Li, Y., K. H. Mei, X. Li, Z. Y. Wang, and S. J. Sun. 2024. “Long-term performance of CFRP tendon composite anchorage under various bonding medium.” China J. Highway Transp. 38 (1): 213–223.
16. Malvar, L. J. 1995. “Tensile and bond properties of GFRP reinforcing bars.” ACI Mater. J. 92 (3): 276–285.
17. 10.1061/JCCOF2.CCENG-406810.1061/JCCOF2.CCENG-4068 ↗
18. 10.1016/j.conbuildmat.2022.12929510.1016/j.conbuildmat.2022.129295 ↗
19. Pay, A. C., E. Canbay, and R. J. Frosch. 2014. “Bond strength of spliced fiber-reinforced polymer reinforcement.” ACI Struct. J. 111 (2): 257–266.
20. 10.1016/j.conbuildmat.2020.11985710.1016/j.conbuildmat.2020.119857 ↗
21. 10.1016/j.conbuildmat.2018.03.16910.1016/j.conbuildmat.2018.03.169 ↗
22. SAC (Standardization Administration of China). 2015. Reactive powder concrete. GB/T 31387-2015. Beijing: SAC.
23. SAC. 2020. Technical standard for fiber reinforced polymer (FRP) in construction. GB 50608-2020. Beijing: SAC.
24. 10.1016/j.conbuildmat.2015.10.08810.1016/j.conbuildmat.2015.10.088 ↗
25. Xue, W. Y., X. Hu, and W. C. Xue. 2023. “Bond-slip constitutive model for glass fiber-reinforced polymers rebars in ultra high-performance concrete.” [In Chinese.] J. Harbin Eng. Univ. 44 (5): 698–707.
26. 10.1016/j.compositesb.2016.04.06810.1016/j.compositesb.2016.04.068 ↗
27. 10.1016/j.compstruct.2014.09.05510.1016/j.compstruct.2014.09.055 ↗
28. 10.1016/j.conbuildmat.2023.13164610.1016/j.conbuildmat.2023.131646 ↗