journal article·2025-10

Flexural Strength and Deformation Capacity of PC Members with Combined Bonded and Unbonded Steel or CFRP Tendons

Mohamed Harajli, Wassim Nasreddine, Hani Nassif

Publisher page

Abstract

Some potential applications where bonded steel or carbon fiber–reinforced polymer (CFRP) tendons are combined with unbonded tendons are in the staged construction of prestressed concrete (PC) members and when strengthening existing PC members using external prestressing. CFRP tendons offer advantages over steel tendons in that they are light, making them easier to handle during construction, but more importantly, they are corrosion-resistant, thereby increasing the life span of the structures and reducing their cost of maintenance. However, since CFRP is a perfectly elastic material, CFRP prestressed concrete members are perceived as nonductile compared to traditional steel prestressed members, which may hinder their application in the construction industry. This is exacerbated by the fact that no guidelines are provided in the codes of practice for designing or analyzing concrete members prestressed using a combination of bonded and unbonded tendons, be it steel or CFRP, and no widely accepted measures are currently available for evaluating their ductility. In this paper, in analogy with the approach adopted in the American codes of practice for traditional PC members, a simple and computationally efficient design-oriented method for evaluating the flexural behavior and nominal moment capacity of combined bonded–unbonded PC members utilizing steel or CFRP tendons (referred to as hybrid members) is presented and generalized expressions for quantifying their ductility or deformation capacity are generated.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

American Univ. of Beirut (AUB)

Rutgers Univ.

References (23)

Show source-provided references
1. AASHTO. 2020. LRFD bridge design specifications. 9th ed. Washington, DC: AASHTO.
2. ACI (American Concrete Institute). 2004. Prestressing concrete structures with FRP tendons. ACI PRC-440.4-04. Farmington Hills, MI: ACI.
3. ACI (American Concrete Institute). 2019. Building code requirements for structural concrete and commentary. ACI 318-19. Farmington Hills, MI: ACI.
4. Chen, L., X. Qiang, P. Sun, S. Zhang, and X. Jiang. 2024. “Experimental and theoretical study on flexural behavior of prestressed concrete beams strengthened by CFRP tendons with external unbonded retrofit system.” J. Build. Eng. 89: 109301. https://doi.org/10.1016/j.jobe.2024.109301.10.1016/j.jobe.2024.109301 ↗
5. CSA (Canadian Standard Association). 2014. Design of concrete structures. CAN/CSA A23.3-14. Rexdale, ON, Canada: CSA.
6. Ghallab, A., and A. W. Beeby. 2001. “Behaviour of PSC beams strengthened by unbonded parafil ropes.” In Proc., Int. Conf. on Fiber-Reinforced Plastics for Reinforced Concrete Structures, edited by C. J. Burgoyne, 671–680. Cambridge, UK: FRPRCS-5.
7. 10.15554/pcij.09012002.20.3510.15554/pcij.09012002.20.35 ↗
8. Han, M. Y., E. S. Hwang, and C. Lee. 2002. “Prestressed concrete girder with multistage prestressing concept.” ACI Struct. J. 100 (6): 723–731.
9. Harajli, M. 2006. “On the stress in unbonded tendons at ultimate: Critical assessment and proposed changes.” ACI Struct. J. 103 (6): 803–812.
10. Harajli, M. H., and A. E. Naaman. 1985. “Evaluation of the ultimate steel stress in partially prestressed flexural members.” PCI J. 30 (5): 54–81. https://doi.org/10.15554/pcij.09011985.54.81.10.15554/pcij.09011985.54.81 ↗
11. Le, H. A., D. Lee, C. Lee, and Y. Kim. 2018. “Flexural behaviour of precast segmental concrete beams internally prestressed with unbonded CFRP tendons under four-point loading.” Eng. Struct. 164: 59–73.
12. Le, T. D., T. M. Pham, H. Hao, and H. Li. 2020. “Behavior of precast segmental concrete beams prestressed with external steel and CFRP tendons.” J. Compos. Constr. 24 (5): 04020036. https://doi.org/10.1061/(ASCE)CC.1943-5614.0001059.
13. Mast, R. F. 1992. “Unified design provisions for reinforced and prestressed concrete flexural and compression members.” ACI Struct. J. 89 (2): 185–199.
14. Menegotto, M., and P. E. Pinto. 1973. “Method of analysis for cyclically loaded RC plane flames including changes in geometry and non-elastic behavior of elements under combined normal force and bending.” In Proc., IABSE Symp. on Resistance and Ultimate Deformability of Structures, 15–22. Lisbon, Portugal: IABSE.
15. Mufti, A. A., J. P. Newhook, and G. Tadros. 1996. “Deformability versus ductility in concrete beams with FRP reinforcement.” In Proc., 2nd Int. Conf. on Advanced Composite Materials in Bridges and Structures. Montreal, Quebec, Canada: Canadian Society for Civil Engineering.
16. 10.1016/0045-7949(83)90017-210.1016/0045-7949(83)90017-2 ↗
17. 10.15554/pcij.05011986.64.8710.15554/pcij.05011986.64.87 ↗
18. Nasreddine, W., A. Obeida, M. Harajli, and H. Nassif. 2024. “Evaluation of flexural strength and ductility of hybrid prestressed concrete members.” ACI Struct. J. 121 (6): 91–103.
19. 10.1016/j.engstruct.2023.11665510.1016/j.engstruct.2023.116655 ↗
20. Nassif, H., O. Ozkul, and M. Harajli. 2003. “Behavior of beams post-tensioned with bonded and unbonded tendons.” J. Post-Tensioning Inst. 1 (1): 59–71.
21. 10.1061/JCCOF2.CCENG-489010.1061/JCCOF2.CCENG-4890 ↗
22. Park R. and T. Paulay. 1975. Reinforced concrete structures. New York: John Wiley & Sons.10.1002/9780470172834 ↗
23. 10.15554/pcij.09011977.84.11010.15554/pcij.09011977.84.110 ↗