Effect of Stress Ratio on the Fatigue Behavior of Ribbed Glass Fiber–Reinforced Polymer Bars for Concrete Reinforcement
Source abstract
Abstract
The fatigue behavior of glass fiber–reinforced polymer (GFRP) bars, a promising alternative to steel reinforcement in corrosive environments, remains inadequately understood, particularly under varying stress ratios [the stress ratio is the minimum stress divided by the maximum stress (R)]. This study investigates the effect of stress ratios on the fatigue life of ribbed GFRP bars through an extensive experimental program tests were conducted under tension–tension cyclic loading at three stress ratios (0.1, 0.4, and 0.6), with an analysis of failure modes, fatigue life, and performance trends. Bars tested at a stress ratio of 0.6 demonstrated a fatigue life approximately 40 times higher than those at 0.1, revealing the significant influence of the stress ratio on material performance. To complement the bar-level investigation, a parallel fatigue testing program was conducted on full-scale concrete beams reinforced with the same ribbed GFRP bars. These beams were tested under a stress ratio of 0.4 and maximum fatigue stress levels of 30% and 35% of the bar’s ultimate tensile strength. While the beams exhibited flexural cracking and some stiffness degradation during cycling, they retained 87%–100% of their static capacity after 2 million cycles, confirming that the endurance threshold observed in the bar tests also holds in structural applications. A proposed fatigue life equation and updated S-N (fatigue stress – number of cycles to failure) curves were developed, incorporating probabilistic models calibrated using the experimental results to improve predictive accuracy. The results highlight limitations in existing design standards and support the development of improved fatigue stress limits for GFRP-reinforced structures. By addressing the relationship between stress ratio and fatigue performance, this work provides new insights into enhancing the durability and reliability of GFRP-reinforced concrete under cyclic loading, bridging a crucial knowledge gap for structural applications.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Mechanical Behavior of Composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Ain Shams Univ.
Concordia Univ.
References (32)
Show source-provided references
1. AASHTO. 2018. Guide specifications for design of concrete bridge decks reinforced with glass fiber-reinforced polymer bars. Washington, DC: AASHTO.
2. AASHTO. 2020. LRFD bridge design specifications. 9th ed. Washington, DC: AASHTO.
3. ACI (American Concrete Institute). 2021. Report on fatigue of concrete structures. ACI 215R-21. Farmington Hills, MI: ACI.
4. ACI (American Concrete Institute). 2022. Building code requirements for structural concrete reinforced with glass fiber-reinforced polymer (GFRP) bars and commentary. ACI 440.11-22. Farmington Hills, MI: ACI.
5. Ahmed, E. A., F. Settecasi, and B. Benmokrane. 2014. “Construction and testing of GFRP steel hybrid-reinforced concrete bridge-deck slabs of Sainte-Catherine Overpass Bridges.” J. Bridge Eng. 19 (10): 04014020. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000581.
6. ASTM. 2017. Standard specification for solid round glass fiber reinforced polymer bars for concrete reinforcement. ASTM D7957/D7957M-17. West Conshohocken, PA: ASTM.
7. ASTM. 2018. Standard test method for compressive strength of cylindrical concrete specimens. ASTM C39/C39M-18. West Conshohocken, PA: ASTM.
8. ASTM. 2021. Standard test method for tensile properties of fiber reinforced polymer matrix composite bars. ASTM D7205/D7205M-21. West Conshohocken, PA: ASTM.
9. Carvelli, V., M. A. Pisani, and C. Poggi. 2010. “Fatigue behavior of RC decks with GFRP reinforcement.” J. Compos. Constr. 14 (6): 789–797.
10. CSA (Canadian Standard Association). 2019. Canadian highway bridge design code. CSA S6-19. Rexdale, ON, Canada: CSA.
11. CSA (Canadian Standard Association). 2021. Design and construction of building structures with fibre-reinforced polymers. CSA S806:12-R21. Rexdale, ON, Canada: CSA.
12. 10.1016/j.conbuildmat.2022.12839510.1016/j.conbuildmat.2022.128395 ↗
13. Elgabbas, F., E. A. Ahmed, and B. Benmokrane. 2017. “Flexural behavior of concrete beams reinforced with glass-fiber-reinforced polymer (GFRP) bars.” ACI Struct. J. 114 (3): 753–764.
14. 10.1061/(ASCE)CC.1943-5614.000041710.1061/(ASCE)CC.1943-5614.0000417 ↗
15. ElSafty A. B. Benmokrane S. Rizkalla H. Hassan and M. Hassan. 2014. “Degradation assessment of internal continuous fiber reinforcement in concrete environment.” Univ. North Florida 270.
16. 10.4028/www.scientific.net/SSP.322.16310.4028/www.scientific.net/SSP.322.163 ↗
17. Janus, O., F. Girgle, I. Rozsypalova, V. Kostiha, L. Bodnarova, P. Stepanek, and J. Prokes. 2019. “The fatigue behaviour of GFRP bars—Experimental study.” In Vol. 2 of Proc., Acta Polytechnica CTU, 38–47. Prague, Czech Republic: Czech Technical University in Prague.
18. Montaser, A., B. Abdelrahman, and K. Galal. 2025. “Interface shear capacity of rough and smooth concrete interfaces with GFRP shear-friction reinforcement.” J. Compos. Constr. 30 (1): 1–19. https://doi.org/10.1061/JCCOF2.CCENG-5287.
19. MST Rebar. 2023. MST-BAR® technical data sheet—Structural rebar. Woodbridge, ON, Canada: MST Rebar.
20. 10.1016/j.engstruct.2024.11798910.1016/j.engstruct.2024.117989 ↗
21. Nagy, I. E., A. Asadian, and K. Galal. 2025. “Tension–tension fatigue behavior of ribbed glass fiber–reinforced polymer bars in air.” J. Compos. Constr. 29 (2): 04024097. https://doi.org/10.1061/JCCOF2.CCENG-4622.
22. Noël M. 2018. “Probabilistic Fatigue Life Modelling of FRP Composites.” In Proc. 4th Brazilian Conf. Compos. Mater. Rio Janeiro Brazil: BCCM4.10.21452/bccm4.2018.06.04 ↗
23. 10.1016/j.conbuildmat.2019.02.08210.1016/j.conbuildmat.2019.02.082 ↗
24. 10.1061/(ASCE)CC.1943-5614.000046810.1061/(ASCE)CC.1943-5614.0000468 ↗
25. 10.1061/(ASCE)CC.1943-5614.000051410.1061/(ASCE)CC.1943-5614.0000514 ↗
26. Nolan, S., and A. J. Aref. 2014. “Fatigue behavior of concrete bridge decks cast on GFRP stay-in-place structural forms.” J. Compos. Constr. 18 (3): 04013048.
27. 10.1007/BF0036783510.1007/BF00367835 ↗
28. 10.2749/guimaraes.2019.121410.2749/guimaraes.2019.1214 ↗
29. Sendeckyj G. P. 1981. “Fitting models to composite materials fatigue data.” In Test Methods and Design Allowables for Fibrous Composites ASTM STP 734 edited by C. C. Chamis 245–260. West Conshohocken PA: American Society for Testing and Materials.10.1520/STP29314S ↗
30. 10.1007/s10443-009-9099-110.1007/s10443-009-9099-1 ↗
31. Warn, G. P., and A. J. Aref. 2010. “Fatigue behavior of concrete bridge decks reinforced with GFRP stay-in-place forms.” J. Compos. Constr. 14 (6): 769–777.
32. 10.1016/j.ijfatigue.2009.02.02710.1016/j.ijfatigue.2009.02.027 ↗