Circular Columns Confined with FRP: Experimental versus Predictions of Models and Guidelines
Source abstract
Abstract
This paper presents results of an experimental investigation on half-scale concrete columns retrofitted with externally bonded fiber reinforced polymers (FRP). It then reviews six selected confinement models and three North American design guidelines for circular columns retrofitted with FRP and provides an in-depth comparison between experimental test results, models predictions, and values obtained using the guidelines. The comparison, which is carried out in terms of the confined to unconfined strengths, but also in terms of the gain in the load carrying capacity, considers the following parameters: The FRP confinement ratio, the unconfined concrete strength, and the elastic and mechanical properties of FRP. The results of this investigation indicated that for columns made of lower strength concrete, existing models and guidelines overestimate the confined concrete strength, and hence, the load carrying capacity of the columns.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Load-Bearing Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Professor, Dept. of Construction Engineering, Univ. of Quebec, 1100, Notre-Dame St. West, Montreal PQ, Canada H3C 1K3.
Research Fellow and Lecturer, Dept. of Construction Engineering, Univ. of Quebec, 1100, Notre-Dame St. West, Montreal PQ, Canada H3C 1K3.
Graduate Student, Dept. of Construction Engineering, Univ. of Quebec, 1100, Notre-Dame St. West, Montreal PQ, Canada H3C 1K3.
References (13)
Show source-provided references
1. ACI-440 Committee. (2002). “Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures.” ACI 440 Detroit.
2. Canadian Standard Association (CSA). (2002). “Design and construction of building components with fibre-reinforced polymers.” CSA-S806-02 CSA Rexdale BD Toronto.
3. 10.1061/(ASCE)1090-0268(2003)7:3(219)10.1061/(ASCE)1090-0268(2003)7:3(219) ↗
4. 10.1680/macr.1982.34.121.19110.1680/macr.1982.34.121.191 ↗
5. Intelligent Sensing for Innovative Structures (ISIS). (2001). “Externally bonded FRP for strengthening reinforced concrete structures.” The Canadian Network of Centres of Excellence on ISIS ISIS M04 Winnipeg Manitoba Canada.
6. Kono S. Inazumi M. and Kaku T. (1998). “Evaluation of confining effects of CFRP sheets on reinforced concrete members.” Proc. 2nd Int. Conf. on Composites in Infrastructure ICCI’98 Ehsani and Saadatmanesh Tucson Ariz. 343–355.
7. 10.1061/(ASCE)0733-9445(1988)114:8(1804)10.1061/(ASCE)0733-9445(1988)114:8(1804) ↗
8. Miyaushi K. Nishibayashi S. and Inoue S. (1997). “Estimation of strengthening effects with carbon fiber sheet for concrete column.” Proc. 3rd Int. Symp. on Non Metallic (FRP) Reinforcement for Concrete Structures Japan Concrete Institute Sapporo Japan Vol. 1 217–232.
9. Monti G. and Spoelstra M. R. (1997). “Fiber-section analysis of RC bridge piers retrofitted with FRP jackets.” Proc. Structures Congress XV ASCE Reston Va. 884–888.
10. 10.1061/(ASCE)0733-9445(1998)124:9(1025)10.1061/(ASCE)0733-9445(1998)124:9(1025) ↗
11. 10.1061/(ASCE)0733-9445(1998)124:9(1025)10.1061/(ASCE)0733-9445(1998)124:9(1025) ↗
12. 10.1061/(ASCE)1090-0268(1997)1:2(52)10.1061/(ASCE)1090-0268(1997)1:2(52) ↗
13. 10.1061/(ASCE)1090-0268(1999)3:3(143)10.1061/(ASCE)1090-0268(1999)3:3(143) ↗