Behavior of Glass Fiber–Reinforced Polymer Reinforced Concrete Continuous T-Beams
Source abstract
Abstract
In this paper, test results of six large-scale glass fiber–reinforced polymer (GFRP) RC continuous T-beams are presented. The test specimens include one steel RC beam to serve as reference, one GFRP RC beam designed to meet the serviceability criteria at the service load level calculated for the reference beam, and four GFRP RC beams designed to achieve the same theoretical ultimate load of the reference beam. The test variables included the assumed percentage of moment redistribution, the spacing of lateral reinforcement in flange, and the arrangement of shear reinforcement. The test results showed that moment redistribution from the hogging to the sagging moment region occurred in GFRP RC beams with T-sections and that a small spacing of stirrups enhanced the moment redistribution percentage. In addition, decreasing the spacing of lateral reinforcement in the flange improved the moment redistribution through enhancing the stiffness of the sagging moment region.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
M.Sc. Student, Dept. of Civil Engineering, Univ. of Manitoba, Winnipeg, MB, Canada R3T 5V6.
Postdoctoral Fellow, Dept. of Civil Engineering, Univ. of Manitoba, Winnipeg, MB, Canada R3T 5V6.
Professor and Canada Research Chair in Durability and Modernization of Civil Structures, Dept. of Civil Engineering, Univ. of Manitoba, Winnipeg, MB, Canada R3T 5V6 (corresponding author).
References (22)
Show source-provided references
1. ACI (American Concrete Institute). (2014). “Building code requirements for reinforced concrete and commentary.” ACI 318-14 Farmington Hills MI.
2. Shear strength of two-span continuous reinforced concrete beams with multiple point loading
3. 10.1139/L08-06410.1139/L08-064 ↗
4. CSA (Canadian Standard Association). (2012). “Design and construction of building structures with fibre-reinforced polymers.” CSA S806-12 Rexdale ON Canada.
5. CSA (Canadian Standard Association). (2014a). “Canadian highway bridge design code.” CSA S6-14 Rexdale ON Canada.
6. CSA (Canadian Standard Association). (2014b). “Code for the design of concrete structures for buildings.” CSA A23.3-14 Rexdale ON Canada.
7. 10.1061/(ASCE)CC.1943-5614.000014010.1061/(ASCE)CC.1943-5614.0000140 ↗
8. 10.1061/(ASCE)CC.1943-5614.000021510.1061/(ASCE)CC.1943-5614.0000215 ↗
9. Moment and shear redistribution in two-span continuous reinforced concrete beams
10. 10.1061/(ASCE)1090-0268(1998)2:4(186)10.1061/(ASCE)1090-0268(1998)2:4(186) ↗
11. 10.1061/(ASCE)1090-0268(2008)12:2(115)10.1061/(ASCE)1090-0268(2008)12:2(115) ↗
12. Jaeger L. G. Tadros G. and Mufti A. (1995). “Balanced section ductility and deformability in concrete with FRP reinforcement.” Research Rep. No. 2-1995 CAD-CAM Technical Univ. of Nova Scotia Halifax NS Canada.
13. 10.1016/j.conbuildmat.2013.03.09410.1016/j.conbuildmat.2013.03.094 ↗
14. 10.1061/(ASCE)CC.1943-5614.000040610.1061/(ASCE)CC.1943-5614.0000406 ↗
15. Effect of transverse reinforcement ratio on the shear strength of GFRP-RC continuous beams
16. 10.1016/j.compstruct.2011.10.02110.1016/j.compstruct.2011.10.021 ↗
17. 10.1680/iicep.1959.1208710.1680/iicep.1959.12087 ↗
18. Mostofinejad D. (1997). “Ductility and moment redistribution in continuous FRP reinforced concrete beams.” Ph.D. thesis Dept. of Civil and Environmental Engineering Carleton Univ. Ottawa.
19. Nilson A. · 2010
20. Shear strength of two-span continuous reinforced concrete beams
21. 10.1016/j.conbuildmat.2013.01.01410.1016/j.conbuildmat.2013.01.014 ↗
22. Contribution to redistribution of moments in continuous reinforced concrete beams