Source abstract
Abstract
The mechanical performance of four types of interfaces between fiber-reinforced polymer (FRP) plate and concrete was compared by double-lap-shear test. The study found that the failure characteristics of the four interfaces are obviously distinct. Among them, the shear capacity load of the shear key combined with wet-bond (SK-WB) interface was the highest, followed by the dry-bond and the coarse-aggregate-coating (CAC) interfaces; the wet-bond interface had the lowest shear load bearing capacity. The type of the resin used for the wet-bond adhesive has a slight influence on the bond strength, whereas the type of the resin used for the shear key bonding has a much more significant effect on the shear capacity load of these interfaces. The thickness of the wet-bond epoxy resin layer also has a significant impact on the bond performance of the wet-bond interface. The shear key forms has less influence when the flexural stiffness of the shear keys itself is sufficient; the load capacity of the SK-WB interface is often dependent on the bonding area between the shear key and the concrete. The concept of bond zone was put out when creating interface model of the SK-WB interface. Finally, unified form formulas of the shear capacity and the interface fracture energy are provided for the different interfaces, and the values of them are estimated.
Source: openalex_inverted_index · Quality: baseline
Affiliations
Lecturer, School of Civil Engineering, Zhengzhou Univ., Zhengzhou 450002, China.
Associate Professor, Key Laboratory of Concrete and Prestressed Concrete Structures of the Ministry of Education, Southeast Univ., Nanjing 210096, China.
Professor, Key Laboratory of Concrete and Prestressed Concrete Structures of the Ministry of Education, Southeast Univ., Nanjing 210096, China (corresponding author).
Professor, Key Laboratory of Concrete and Prestressed Concrete Structures of the Ministry of Education, Southeast Univ., Nanjing 210096, China.