journal article·2007-04

Bond Behavior of CFRP Bars in Simply Supported Reinforced Concrete Beam with Hanging Region

Rendy Thamrin, Tetsuzo Kaku

Publisher page

Abstract

This paper presents an experimental study on the bond behavior of longitudinal reinforcements in the hanging region (i.e., the part of the beam outside the support) of a simply supported reinforced concrete beam. Twenty-three reinforced concrete beams were tested to failure. Carbon fiber-reinforced polymer (CFRP) bars were used as longitudinal reinforcements in place of ordinary steel bars. The main test variables were (1) stirrup ratio in the hanging region; (2) stirrup ratio in the shear span; and (3) bond length in the hanging region. The test results showed that, even though the beam had a sufficient stirrup ratio in the shear span, bond-splitting failure occurred in the shear span of the beam with insufficient bond length in the hanging region. Based on the test results, the provision of ACI and AIJ codes on the additional anchorage length in the hanging region was evaluated, and a model for predicting tension force at the support was presented.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Doctoral Student, Dept. of Architectural and Civil Engineering, Toyohashi Univ. of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580, Japan. E-mail: rendy@rcvx.tutrp.tut.ac.jp

Professor, Dept. of Architectural and Civil Engineering, Toyohashi Univ. of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580, Japan. E-mail: kaku@rcvx.tutrp.tut.ac.jp

References (10)

Show source-provided references
1. AIJ · 1999
2. American Concrete Institute (ACI). (2005). “Building code requirements for structural concrete and commentary.” ACI 318-05/318R-05 Farmington Hills Mich.
3. American Concrete Institute (ACI). (2003). “Guide for the design and construction of concrete reinforced with FRP bars.” ACI 440.1R-03 Farmington Hills Mich.
4. Comité Euro-International du Béton (CEB) · 1985
5. 10.1061/(ASCE)0733-9445(1996)122:3(247)10.1061/(ASCE)0733-9445(1996)122:3(247) ↗
6. Komiya I. Kaku T. and Kutsuna H. (1999). “Bond characteristic of FRP rods (No. 3).” Proc. AIJ Annual Conf. 1999 Japan 623–624 (in Japanese).
7. Morita S. and Fujii S. (1982). “Bond capacity of deformed bars due to splitting of surrounding concrete.” Bond in Concrete Proc. Int. Conf. Paisley College of Technology Scotland 331–341.
8. Revaluation of the equation for shear strength of reinforced concrete beams without web reinforcement
9. 10.1002/978047017283410.1002/9780470172834 ↗
10. Thamrin R. Ngoc T. T. Samnang H. Yoshikawa N. and Kaku T. (2004). “Bond behavior of CFRP rods in RC beam with hanging region.” Proc. 2nd Int. Conf. on FRP Composites in Civil Engineering Adelaide Australia 361–369.10.1201/9780203970850.ch39 ↗