journal article·2016-12

Fatigue Bond Stress–Slip Behavior of Lap Splices in the Reinforcement of Unwrapped and FRP-Wrapped Concrete Beams

Rayed Alyousef, Tim Topper, Adil Al-Mayah

Publisher page

Abstract

This paper presents an experimental study on the effect of fiber-reinforced polymer (FRP) wrapping on the fatigue performance and bond strength of reinforced concrete beams containing a lap splice at a constant moment region under cyclic loading. In addition, the study presents the slip response of the steel bars. Fifteen beams were investigated that were divided into three groups, namely: unwrapped, glass fiber-reinforced polymer (GFRP) wrapped, and carbon fiber-reinforced polymer (CFRP) wrapped. The test variables were the presence or absence of FRP wrapping, the type of the FRP wrapping (GFRP or CFRP), the type of loading (monotonic or fatigue loading), and the fatigue load range. The results of the tests under monotonic load showed a significant increase in load and deflection for the FRP-wrapped beams compared to the unwrapped beams. The increase in the unwrapped beams load deflection results for the CFRP-wrapped beams was greater than that for the GFRP-wrapped beams. Also, the FRP-wrapped beams had higher fatigue strengths than the unwrapped beams. The bond stress slip response under monotonic and fatigue loading is compared.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Ph.D. Student, Univ. of Waterloo, 200 University Ave. W, Waterloo, ON, Canada N2L 3G1; presently, Lecturer, on leave, Dept. of Civil Engineering, Prince Sattam Bin Abdulaziz Univ., Al-Kharj, Saudi Arabia (corresponding author).

Distinguished Professor Emeritus, Univ. of Waterloo, 200 University Ave. W, Waterloo, ON, Canada N2L 3G1.

Assistant Professor, Dept. of Civil and Environmental Engineering/Dept. of Mechanical and Mechatronics Engineering, Univ. of Waterloo, ON, Canada N2L 3G1.

References (18)

Show source-provided references
1. ACI (American Concrete Institute). (2003). “Bond and development of straight reinforcing bars in tension.” ACI 408-03 Detroit.
2. ACI (American Concrete Institute). (2012). “Report on bond of steel reinforcing bars under cyclic loads.” ACI 408.2R-12 Detroit.
3. Effect of FRP wrapping on fatigue bond behavior of spliced concrete beams
4. Fatigue of bond
5. 10.1061/(ASCE)CC.1943-5614.000007810.1061/(ASCE)CC.1943-5614.0000078 ↗
6. 10.1080/1363246060112571410.1080/13632460601125714 ↗
7. Eligehausen R. Popov E. and Bertero V. (1983). “Local bond stress-slip relationships of deformed bars under generalized excitations.” Rep. No. UCB/EERC-83/23 Univ. of California Berkeley CA.
8. FIB (International Federation for Structure Concrete). (2000). “Bond of reinforcement in concrete.” FIB 10 Lausanne Switzerland.
9. 10.1617/s11527-013-0183-510.1617/s11527-013-0183-5 ↗
10. 10.1061/(ASCE)1090-0268(2006)10:4(330)10.1061/(ASCE)1090-0268(2006)10:4(330) ↗
11. 10.1061/(ASCE)1090-0268(2004)8:1(14)10.1061/(ASCE)1090-0268(2004)8:1(14) ↗
12. 10.1061/(ASCE)0899-1561(2002)14:6(503)10.1061/(ASCE)0899-1561(2002)14:6(503) ↗
13. 10.1016/j.conbuildmat.2008.07.02810.1016/j.conbuildmat.2008.07.028 ↗
14. Effect of confinement on bond strength between steel bars and concrete
15. Helgason T. and Hanson J. M. (1974). “Investigation of design factors affecting fatigue strength of reinforcing steel—Statistical analysis.” SP-41: Abeles Symp. Fatigue of Concrete American Concrete Institute Detroit 107–138.
16. A reevaluation of test data on development length and splices
17. 10.1016/j.conbuildmat.2006.06.02210.1016/j.conbuildmat.2006.06.022 ↗
18. 10.1061/(ASCE)0899-1561(2003)15:4(358)10.1061/(ASCE)0899-1561(2003)15:4(358) ↗