journal article·2013-12

Comparative Experimental Performance of Bridge Deck Slabs with AFRP and Steel Precast Panels

Shobeir Pirayeh Gar, Monique Head, Stefan Hurlebaus, John B. Mander

Publisher page

Abstract

Full-depth precast concrete panels expedite the construction process, enhance the safety and quality controls, and reduce the on-site labor requirements for bridge deck slab applications. However, corrosion-induced deterioration of conventional steel during the lifetime of the structure is a serious concern affecting the durability and serviceability of the deck panels. Although replacing conventional steel with fiber-reinforced polymer (FRP) bars has become more prevalent over the past few decades to overcome corrosion issues, there is still need for a comprehensive experimental study to investigate the constructability and structural performance of FRP concrete bridge deck slabs with precast panels at full scale. In this paper, a full-scale bridge deck slab consisting of full-depth precast panels reinforced and prestressed with aramid fiber reinforced polymer (AFRP) bars is experimentally investigated in terms of constructability and overall structural performance. It is then compared to a similar system but reinforced with conventional steel and prestressing strand, deemed as the control specimen. The experimental results show the applicability of the proposed system having acceptable strength and serviceability per AASHTO LRFD Bridge Design Specifications and considerable deformability, when compared to the conventional system.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Concrete Corrosion and Durability · Structural Behavior of Reinforced Concrete · Corrosion Behavior and Inhibition

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Structural Engineer, Houston Offshore Engineering, Houston, TX 77079; formerly, Graduate Assistant Researcher, Zachry Dept. of Civil Engineering, Texas A&M Univ., College Station, TX 77843-3136 (corresponding author).

Assistant Professor, Dept. of Civil Engineering, Morgan State Univ., Baltimore, MD 21251.

Associate Professor, Zachry Dept. of Civil Engineering, Texas A&M Univ., College Station, TX 77843-3136.

Zachry Professor I, Zachry Dept. of Civil Engineering, Texas A&M Univ., College Station, TX 77843.

References (27)

Show source-provided references
1. AASHTO. (2010). LRFD bridge design specifications Washington DC.
2. Test model for the first Canadian smart highway bridge
3. American Concrete Institute (ACI). (2004). “Prestressing concrete structures with FRP tendons.” ACI 440.4R-04 Detroit.
4. American Concrete Institute (ACI). (2006). “Guide for the design and construction of structural concrete reinforced with FRP bars.” ACI 440.1R-06 Detroit.
5. American Concrete Institute (ACI). (2008). “Building code requirements for structural concrete and commentary.” ACI 318-08 Detroit.
6. ASTM. (2008a). “Standard test method for compressive strength of cylindrical concrete specimens.” C39 West Conshohocken PA.
7. ASTM. (2008b). “Standard test method for compressive strength of grouts for preplaced-aggregate concrete in the laboratory.” C942 West Conshohocken PA.
8. ASTM. (2008c). “Standard test method for flow of grout for preplaced-aggregate concrete.” C939 West Conshohocken PA.
9. ASTM. (2008d). “Standard test method for flow table for use in tests of hydraulic cement.” C230/C230M West Conshohocken PA.
10. Chen Y. (2007). “Accelerated aging tests and long-term prediction models for durability of FRP bars in concrete.” Ph.D. dissertation West Virginia Univ. Morgantown WV.
11. Dolan C. W. Hamilton H. R. Bakis C. E. and Nanni A. (2000). “Design recommendations for concrete structures prestressed with FRP tendons final report.” Rep. DTFH61-96-C-00019 Dept. of Civil and Architectural Engineering Univ. of Wyoming Laramie WY.
12. 10.1061/(ASCE)1090-0268(2007)11:5(449)10.1061/(ASCE)1090-0268(2007)11:5(449) ↗
13. Serviceability of concrete bridge deck slabs reinforced with FRP composite bars
14. Precast panel composite bridge decks
15. Precast prestressed concrete bridge deck panels
16. 10.1139/l99-09810.1139/l99-098 ↗
17. Experimental behavior of full-depth precast concrete panels for bridge rehabilitation
18. Mander T. J. (2009). “Structural performance of a full scale precast concrete bridge deck system.” M.S. thesis Texas A&M Univ. College Station TX.
19. 10.1061/(ASCE)BE.1943-5592.000009810.1061/(ASCE)BE.1943-5592.0000098 ↗
20. 10.1061/(ASCE)BE.1943-5592.000013810.1061/(ASCE)BE.1943-5592.0000138 ↗
21. Medina J. C. (2011). “Characteristics of AFRP bars for prestressing application.” M.S. thesis Texas A&M Univ. College Station TX.
22. 10.17226/1393410.17226/13934 ↗
23. Pirayeh Gar S. (2012). “Structural performance of a full-depth precast bridge deck system prestressed and reinforced with AFRP bars.” Ph.D. dissertation Texas A&M Univ. College Station TX.
24. 10.1061/(ASCE)1090-0268(2000)4:1(16)10.1061/(ASCE)1090-0268(2000)4:1(16) ↗
25. Laboratory evaluation and field application of concrete reinforcement with aramid fiber-reinforced polymer bars
26. Trejo D. et al. (2008). “Development of a precast bridge deck overhang system for the Rock Creek Bridge.” Technical Rep. 0-6100-2 Texas Transportation Institute (TTI) College Station TX.
27. Trejo D. Aguiniga C. Buth E. Yuan R. James R. W. and Keating P. (2000). “FRP reinforcing bars in bridge decks: State-of-the-art review.” Res. Rep. 1520-2 Texas Transportation Institute (TTI) College Station TX.