journal article·2016-04

Design, Development, and Testing of a Composite Roofing System

Brandon Mintz, Arindam Gan Chowdhury, Amir Mirmiran, Nakin Suksawang, Ramtin Kargarmoakhar

Publisher page

Abstract

Roofing is one of the most vulnerable parts of the building envelope in a residential structure, often damaged during extreme wind events such as hurricanes or tornadoes. Conventional roofing systems in residential buildings mostly consist of separate the main wind force resisting system (MWFRS) and components and cladding (C&C). High wind uplift forces often cause partial or full destruction of one or more of these elements, leading to water intrusion and losses of interior contents. This study focuses on the design, development, and testing of a new composite roofing system that integrates the functionalities of the MWFRS and C&C. The new system is composed of lightweight concrete panels reinforced with fiber-reinforced polymer mesh and rods. The architectural shape of a conventional residential roof with high profile tiles was adopted for the composite roof panels to help provide the requisite structural stiffness and strength of the MWFRS, while maintaining similar C&C aesthetics and avoiding failure of individual tiles that often become wind-borne debris. The panel system was subjected to a battery of tests under equivalent wind loads. In addition, three connections for the system were designed and validated through testing. The panel-to-wall connection provided ample continuity of the vertical load path; the panel to panel connection was found adequate for shear transfer; and the ridge connection allowed for load transfer between the windward and leeward sides of the roof. Tests demonstrated the structural viability of the new system as an alternative to conventional roofs, making it ideal for residential buildings in hurricane zones and tornado alleys. The purpose of the paper is to present details of the system and their structural reliability. Durability and constructibility issues, including cracking, are the object of future work.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Wind and Air Flow Studies · Tropical and Extratropical Cyclones Research · Aeolian processes and effects

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Project Engineer, Twenty First Century Engineering, 826 NE 20th Ave., Fort Lauderdale, FL 33304.

Associate Professor, Dept. of Civil and Environmental Engineering, Florida International Univ., 10555 West Flagler St., EC 3604, Miami, FL 33174 (corresponding author).

Professor and Dean, College of Engineering and Computing, Florida International Univ., 10555 West Flagler St., EC 2477, Miami, FL 33174.

Assistant Professor, Dept. of Civil Engineering, Florida Institute of Technology, F.W. Olin Engineering Complex, 204, Melbourne, FL 32901.

Graduate Student, Dept. of Civil and Environmental Engineering, Florida International Univ., 10555 West Flagler St., EC 3660, Miami, FL 33174.

References (25)

Show source-provided references
1. ACI. (2013). “Building code requirements for structural concrete.” ACI 318 Farmington Hills MI.
2. ASCE. (2010). “Minimum design loads for buildings and other structures.” ASCE 7 Washington DC.
3. Ayscue J. (1996). “Hurricane damage to residential structures: Risk and mitigation.” Johns Hopkins Univ. Baltimore MD.
4. 10.1016/j.buildenv.2014.03.00210.1016/j.buildenv.2014.03.002 ↗
5. Estimation of wind-driven rain intrusion through building envelope defects and breaches during tropical cyclones
6. 10.1016/j.jweia.2014.06.02310.1016/j.jweia.2014.06.023 ↗
7. Bright R. (2010). “NWS Charleston SC-hurricane Hugo.” 〈http://www.erh.noaa.gov/chs/events/hugo.shtml〉 (Feb. 16 2010).
8. 10.1177/109963621036544110.1177/1099636210365441 ↗
9. Testing and analysis of the toe-nailed connection in the residential roof-to-wall system
10. Chomarat. (2010). “Technical data sheet—C50-1.8 x 1.6.” 〈http://www.chomarat.com/wp-content/uploads/2011/06/C50-1.8x1.6.pdf〉 (May 2 2011).
11. Wind-loading effects on roof-to-wall connections of timber residential buildings
12. Cook R. (1991). “Lessons learned by a roof consultant.” Proc. Symp. and Public Forum Hurricane Hugo One Year Later ASCE Reston VA 144–152.
13. FBC (Florida Building Code). (2010). “Chapter 15: Roof assemblies and rooftop structures.” International Code Council Country Club Hills IL.
14. Li R. (2012). “Effects of architectural features of air-permeable roof cladding materials on wind-induced uplift loading.” ProQuest ETD Collection for FIU.
15. Manning B. R. · 1991
16. Marshall Composites Systems. (1999). “C-bar—Product guide specification.” 〈http://www.marshallcomposite.com/c_bar_specs.pdf〉 (Apr. 13 2012).
17. MDC-BCCO. (2006). “Post Hurricane Wilma progress assessment.” Miami-Dade County Building Code Compliance Office Miami FL.
18. NAHB. (1993). “Assessment of damage to single-family homes caused by Hurricane Andrew and Iniki.” NAHB Research Center Rep. Upper Marlboro MD.
19. A novel precast roofing scheme for affordable housing
20. Taylor H. (2014). “Cost of constructing a home.” 〈HousingEconomics.com〉 (May 15 2014).
21. 10.1061/(ASCE)0733-9445(2009)135:2(169)10.1061/(ASCE)0733-9445(2009)135:2(169) ↗
22. 10.12989/was.2010.13.3.22110.12989/was.2010.13.3.221 ↗
23. 10.1061/(ASCE)ST.1943-541X.000003810.1061/(ASCE)ST.1943-541X.0000038 ↗
24. 10.1016/j.jweia.2007.01.00310.1016/j.jweia.2007.01.003 ↗
25. Wight J. K. · 2009