journal article·2019-12

Rehabilitation of Reinforced Concrete Circular Columns with Sprayed-Glass Fiber–Reinforced Polymer Composites

Syed Abdullah Mohit, Ehab El-Salakawy

Publisher page

Abstract

The seismic behavior of reinforced concrete (RC) circular columns rehabilitated with sprayed-glass fiber–reinforced polymer (GFRP) composites was investigated in this study. Six large-scale RC circular columns were constructed and tested under simultaneous reversed-cyclic lateral loads and a constant axial load. All columns had a diameter of 305 mm with 1,525-mm shear span and were deficient in lap-splice length at the footing-column joint. The six specimens were divided into two identical series. In each series, one specimen was rehabilitated after being fully damaged, one was rehabilitated after being partially damaged (up to 2.5% drift ratio), and one was strengthened without prior loading. The difference between the two series was the thickness of the sprayed-GFRP confinement: 3.0 and 6.0 mm. It was concluded that the 3-mm-thick sprayed GFRP was inadequate for rehabilitation of the fully damaged column; however, it can be used for the rehabilitation of undamaged and partially damaged columns. Sprayed GFRP of 6-mm thickness not only increased the drift capacity of the column but also significantly increased the lateral load capacity of seismically deficient RC circular columns.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Response to Dynamic Loads · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

M.Sc. Student, Dept. of Civil Engineering, Univ. of Manitoba, 15 Gillson St., Winnipeg, MB, Canada R3T 5V6.

Professor, Dept. of Civil Engineering, Univ. of Manitoba, 15 Gillson St., Winnipeg, MB, Canada R3T 5V6 (corresponding author).

References (13)

Show source-provided references
1. 10.1061/(ASCE)CC.1943-5614.000063710.1061/(ASCE)CC.1943-5614.0000637 ↗
2. 10.1139/l00-02710.1139/l00-027 ↗
3. Sprayed fiber-reinforced polymers: From laboratory to a real bridge
4. Boyd A. J. 2000. “Rehabilitation of reinforced concrete beams with sprayed glass fiber reinforced polymers.” Ph.D. thesis Dept. of Civil Engineering Univ. of British Columbia.
5. FHWA (Federal Highway Administration) · 2017
6. 10.1061/(ASCE)1084-0702(2005)10:6(749)10.1061/(ASCE)1084-0702(2005)10:6(749) ↗
7. Sprayed-fiber-reinforced composite materials for infrastructure rehabilitation
8. 10.1016/S0263-8223(03)00156-910.1016/S0263-8223(03)00156-9 ↗
9. 10.1177/073168440708768710.1177/0731684407087687 ↗
10. 10.3390/polym804010710.3390/polym8040107 ↗
11. 10.1061/(ASCE)CC.1943-5614.000077710.1061/(ASCE)CC.1943-5614.0000777 ↗
12. Lateral displacement ductility of reinforced concrete flat plates
13. 10.4028/www.scientific.net/AMM.501-504.159210.4028/www.scientific.net/AMM.501-504.1592 ↗