Predicting Strength of FRP-Reinforced Concrete Deep Beams with Stirrups Using the Indeterminate Strut–Tie Method
Source abstract
Abstract
This paper presents the proposed indeterminate strut and tie (IST) method to analyze fiber-reinforced polymer (FRP)-reinforced concrete deep beams with stirrups. The solution of the IST method does not require the assumption of reinforcement yielding and is capable of reflecting the material nonlinearity of concrete. The essential features of the IST methodology for glass FRP-reinforced deep beams are discussed and then analyzed in detail. These features include modeling concrete compressive response, softening concrete compression behavior in struts, and obtaining the depth of compression nodes. For each of these features, several approaches are discussed. The proposed IST methodology is validated by comparing the analysis results with the experimental results, and recommendations for the most suitable modeling methods are proposed.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Doctoral Candidate, Dept. of Civil and Environmental Engineering, Univ. of Waterloo, 200 University Ave. West, Waterloo, ON, Canada N2L 3G1.
Professor, Dept. of Civil and Environmental Engineering, Univ. of Waterloo, 200 University Ave. West, Waterloo, ON, Canada N2L 3G1 (corresponding author). ORCID: .
References (30)
Show source-provided references
1. ACI (American Concrete Institute). 2007. Report on fiber-reinforced polymer (FRP) reinforcement for concrete structures. ACI PRC-440-07. Farmington Hills, MI: ACI.
2. ACI (American Concrete Institute). 2008. Building code requirements for structural concrete and commentary. ACI CODE-318-08. Farmington Hills, MI: ACI.
3. ACI (American Concrete Institute). 2019. Building code requirements for structural concrete and commentary (reapproved 2022). ACI CODE-318-19(22). Farmington Hills, MI: ACI.
4. ACI (American Concrete Institute). 2022. Building code requirements for structural concrete reinforced with glass fiber-reinforced polymer (GFRP) bars—Code and commentary. ACI CODE-440.11-22. Farmington Hills, MI: ACI.
5. Apinis, R., J. Modniks, V. Tamuzs, and R. Tepfers. 1998 “Ductility of hybrid fiber composite reinforcement FRP for concrete.” In Proc., 8th European Conf. on Composite Materials (ECCM8), 89–96. Cambridge, UK: Woodhead Publishing.
6. 10.1016/j.engstruct.2018.02.07710.1016/j.engstruct.2018.02.077 ↗
7. 10.1016/j.compstruct.2019.11171510.1016/j.compstruct.2019.111715 ↗
8. CSA (Canadian Standards Association). 2012. Design and construction of building structure with fibre-reinforced polymers. CSA S806:12 (R2021). Mississauga: CSA.
9. CSA (Canadian Standards Association). 2019. Design of concrete structure. CSA A23.3:19. Toronto: CSA.
10. Hognestad, E., N. W. Hanson, and D. McHenry. 1955. “Concrete stress distribution in ultimate strength design.” J. Am. Concr. Inst. 27 (4): 455–479.
11. 10.3390/fib604009910.3390/fib6040099 ↗
12. 10.1260/1369-4332.14.6.103110.1260/1369-4332.14.6.1031 ↗
13. 10.1260/1369-4332.14.6.104310.1260/1369-4332.14.6.1043 ↗
14. 10.1016/j.compositesb.2013.08.00910.1016/j.compositesb.2013.08.009 ↗
15. 10.1016/j.engstruct.2019.10933310.1016/j.engstruct.2019.109333 ↗
16. MacGregor, J. G., and J. K. Wight. 2011. Reinforced concrete mechanics and design. Hoboken, NJ: Pearson Education.
17. 10.1061/(ASCE)CC.1943-5614.000074710.1061/(ASCE)CC.1943-5614.0000747 ↗
18. Mihaylov, B. I., E. C. Bentz, and M. P. Collins. 2013. “Two-parameter kinematic theory for shear behavior of deep beams.” ACI Struct. J. 110 (3): 447–455.
19. Mohamed, K., A. S. Farghaly, and B. Benmokrane. 2017. “Effect of vertical and horizontal web reinforcement on the strength and deformation of concrete deep beams reinforced with GFRP bars.” J. Struct. Eng. 14 (8): 04017079. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001786.10.1061/(ASCE)ST.1943-541X.0001786 ↗
20. 10.1617/s11527-008-9359-910.1617/s11527-008-9359-9 ↗
21. 10.14359/5168875210.14359/51688752 ↗
22. Pang, X. B., and T. T. C. Hsu. 1995. “Behavior of reinforced concrete membrane elements in shear.” ACI Struct. J. 92 (6): 665–677.
23. 10.15554/pcij.05011987.74.15010.15554/pcij.05011987.74.150 ↗
24. Stoner, J. G., and M. A. Polak. 2020. “Finite element modelling of GFRP reinforced concrete beams.” Comput. Concr. 25 (4): 369–382.
25. Tamuzs, V., R. Apinis, U. Vilks, J. Modniks, and R. Tepfers. 1996 “Ductility of hybrid fiber composite reinforcement FRP for concrete.” In Proc., 1st Int. Conf. on Composites in Infrastructure, 196–122. Tucson, Arizona: University of Arizona.
26. Teng, J. G., J. F. Chen, S. T. Smith, and L. Lam. 2002. FRP: Strengthed RC structures. Chichester, UK: Wiley.
27. The MathWorks Inc. 2019. MATLAB version 9.6.0 (R2019a). Natick, MA: MathWorks.
28. Thorenfeldt, E., A. Tomaszewics, and J. J. Jensen. 1987 “Mechanical properties of high strength concrete and application in design.” In Proc., Symp. on Utilization of High Strength Concrete. Trondheim, Norway: Tapir.
29. Vecchio, F. J., and M. P. Collins. 1986. “The modified compression-field theory for reinforced concrete elements subjected to shear.” ACI J. 83 (2): 219–231.
30. Yun, Y. M. 2000. “Nonlinear strut-tie model approach for structural concrete.” ACI Struct. J. 97 (4): 581–590.