journal article·2008-08

Fatigue Behavior of Concrete-Filled Fiber-Reinforced Polymer Tubes

Iftekhar Ahmad, Zhenyu Zhu, Amir Mirmiran

Publisher page

Abstract

To date, research on concrete-filled fiber-reinforced polymer (FRP) tubes (CFFT) has focused on the effect of static loads, simulated seismic loads, and long-term sustained loads. Dynamic fatigue behavior of CFFTs, on the other hand, has received little or no attention. This paper reports on an experimental study to evaluate damage accumulation, stiffness degradation, fatigue life, and residual bending strength of CFFT beams. A total of eight CFFT beams with four different types of FRP tube were tested under four point bending. Test parameters included reinforcement index, fiber architecture, load range, and end restraints. Fatigue performance of CFFT beams is clearly governed by characteristics of the FRP tube and its three phases of damage growth: matrix cracking, matrix delamination, and fiber rupture. Lower reinforcement index increases stiffness degradation and damage growth, and shortens fatigue life. End restraints, e.g., embedment of FRP tube in adjacent members, promote composite action, arrest slippage of concrete core, and enhance fatigue life of CFFT beams. It is suggested that a maximum load level of 25% of the static capacity be imposed for fatigue design of CFFTs. With proper design, CFFTs may withstand repeated traffic loading necessary for bridge girders.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Structural Engineer, DeSimone Consulting Engineers, 18 W 18th St., 10th Fl., New York, NY 10011. E-mail: iahmad25@yahoo.com

Structural Engineer, URS Corp., 7650 Corporate Center Dr., Ste. 401, Miami, FL 33126. E-mail: zhuz@fiu.edu

Professor and Interim Dean, Dept. of Civil and Environmental Engineering, Florida International Univ., Miami, FL 33174. E-mail: mirmiran@fiu.edu

References (20)

Show source-provided references
1. Ahmad I. (2004). “Shear response and bending fatigue behavior of concrete-filled fiber reinforced polymer tubes.” Ph.D. thesis North Carolina State Univ. Raleigh N.C.
2. 10.1061/(ASCE)1090-0268(1999)3:2(63)10.1061/(ASCE)1090-0268(1999)3:2(63) ↗
3. 10.1061/(ASCE)0733-9445(1995)121:7(1079)10.1061/(ASCE)0733-9445(1995)121:7(1079) ↗
4. 10.1061/(ASCE)0899-1561(1993)5:1(96)10.1061/(ASCE)0899-1561(1993)5:1(96) ↗
5. 10.1061/(ASCE)1090-0268(2001)5:4(258)10.1061/(ASCE)1090-0268(2001)5:4(258) ↗
6. 10.1061/(ASCE)1090-0268(2002)6:2(123)10.1061/(ASCE)1090-0268(2002)6:2(123) ↗
7. 10.1061/(ASCE)1090-0268(2004)8:2(132)10.1061/(ASCE)1090-0268(2004)8:2(132) ↗
8. Fatigue strength of concrete under varying flexural stresses
9. 10.1023/A:100897480407710.1023/A:1008974804077 ↗
10. 10.1016/0167-8442(95)00028-D10.1016/0167-8442(95)00028-D ↗
11. Composite pile: A successful drive
12. 10.1016/S0950-0618(97)00073-110.1016/S0950-0618(97)00073-1 ↗
13. Large beam-column tests on concrete-filled composite tubes
14. 10.1061/(ASCE)1090-0268(2002)6:4(272)10.1061/(ASCE)1090-0268(2002)6:4(272) ↗
15. Pando M. Fam A. Lesko J. and Filz G. (2003). “New bridge piers using load bearing concrete-filled GFRP tubes.” Field application of FRP reinforcement: Case studies SP-215 ACI 181–200.
16. 10.1061/(ASCE)1090-0268(2001)5:4(246)10.1061/(ASCE)1090-0268(2001)5:4(246) ↗
17. 10.2749/10168669978048165510.2749/101686699780481655 ↗
18. 10.1061/(ASCE)0733-9445(1999)125:6(613)10.1061/(ASCE)0733-9445(1999)125:6(613) ↗
19. 10.1061/(ASCE)1090-0268(2005)9:3(263)10.1061/(ASCE)1090-0268(2005)9:3(263) ↗
20. Zhao L. Burgueno R. Rovere H. Seible F. and Karbhari V. M. (2000). “Preliminary evaluation of the hybrid tube bridge system.” Structural systems research project TR-2000/4 Dept. of Structural Engineering Univ. of California San Diego Calif.