Resistance Factors for Ductile FRP-Reinforced Concrete Flexural Members
Source abstract
Abstract
To prevent damage caused by corroding reinforcement, fiber-reinforced polymer (FRP) reinforcing bars have been used in place of steel in a relatively small but increasing number of structures in civil infrastructure. A concern with the use of traditional FRP bars, however, is the resulting lack of ductility. This problem has been overcome with the development of a new generation of composite reinforcement, ductile hybrid FRP (DHFRP) bars. However, standards that address the design of DHFRP bars are unavailable, and appropriate resistance factors for the use of DHFRP reinforcement are unknown. In this paper, a reliability analysis is conducted on tension-controlled concrete flexural members reinforced with DHFRP with the intent to estimate potential strength-reduction factors. Flexural members considered include a selection of representative bridge decks and building beams designed to meet strength requirements and target reliability levels dictated by relevant engineering standards. Nominal moment capacity is calculated from standard analytical models and is taken as first DHFRP material failure. Statistical parameters for load and resistance random variables in the reliability model are consistent with previous code calibration efforts. The resulting resistance factors ranged from 0.61–0.64 for tension-controlled sections, which indicates a potential increase in allowed strength with respect to flexural members using nonductile bars.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Load-Bearing Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Assistant Professor, Dept. of Civil Engineering Technology, Broom Community College, Binghamtom, NY 13905.
Associate Professor, Dept. of Civil and Environmental Engineering, Wayne State Univ., Detroit, MI 48202 (corresponding author).
References (37)
Show source-provided references
1. AASHTO. (2009). Bridge design guide specifications for GRFP-reinforced concrete bridge decks and traffic railings Washington DC.
2. AASHTO · 2010
3. American Concrete Institute (ACI). (2006). “Guide for the design and construction of structural concrete reinforced with FRP bars.” 440.1R-06 Farmington Hills MI.
4. American Concrete Institute (ACI). (2011). “Building code requirements for structural concrete and commentary.” 318-11 Farmington Hills MI.
5. 10.1016/j.compositesb.2007.06.00410.1016/j.compositesb.2007.06.004 ↗
6. 10.1016/S0266-3538(00)00184-610.1016/S0266-3538(00)00184-6 ↗
7. 10.1002/978047012142910.1002/9780470121429 ↗
8. 10.1061/(ASCE)1090-0268(2006)10:3(204)10.1061/(ASCE)1090-0268(2006)10:3(204) ↗
9. 10.1088/0964-1726/10/3/30110.1088/0964-1726/10/3/301 ↗
10. 10.1016/j.conbuildmat.2005.02.00710.1016/j.conbuildmat.2005.02.007 ↗
11. 10.1016/j.conbuildmat.2011.07.01410.1016/j.conbuildmat.2011.07.014 ↗
12. 10.1260/1369-4332.13.1.8110.1260/1369-4332.13.1.81 ↗
13. 10.1088/0508-3443/3/3/30210.1088/0508-3443/3/3/302 ↗
14. 10.1139/L09-01210.1139/L09-012 ↗
15. 10.1061/(ASCE)MT.1943-5533.000039810.1061/(ASCE)MT.1943-5533.0000398 ↗
16. Structural reliability analysis of composite advanced sail for Virginia class submarine10.5957/jsr.2008.52.3.165 ↗
17. Federal Highway Administration (FHWA). (2001). “Long-term effectiveness of cathodic protection systems on highway structures.” Rep. No. FHWA-RD-01-096 McLean VA.
18. 10.1061/(ASCE)1090-0268(1998)2:1(28)10.1061/(ASCE)1090-0268(1998)2:1(28) ↗
19. Inelastic behavior in tests of eccentrically loaded short reinforced concrete columns
20. Krenchel H. · 1964
21. 10.1016/j.scient.2011.03.00510.1016/j.scient.2011.03.005 ↗
22. 10.1061/(ASCE)1090-0268(2002)6:3(162)10.1061/(ASCE)1090-0268(2002)6:3(162) ↗
23. Naaman A. E. and Jeong S. M. (1995). “Structural ductility of concrete beams prestressed with FRP tendons.” Proc. Int. RILEM Symp. Bagneux France 1466–1469.
24. Nowak A. S. (1999). “Calibration of LRFD bridge design code.” National Cooperative Highway Research Program (NCHRP) Rep. 368 Transportation Research Board Washington DC.
25. 10.1061/(ASCE)1084-0702(2002)7:5(290)10.1061/(ASCE)1084-0702(2002)7:5(290) ↗
26. 10.1061/(ASCE)0733-9445(1995)121:7(1037)10.1061/(ASCE)0733-9445(1995)121:7(1037) ↗
27. Ribeiro S. E. C. and Diniz S. M. C. (2012). “Strength and reliability of FRP-reinforced concrete beams.” Proc. Int. Conf. on Bridge Maintenance Safety and Management Taylor & Francis London 2280–2287.10.1201/b12352-342 ↗
28. Shield C. K. · 2011
29. Flexural capacity of singly reinforced beam with 150 MPa ultra high-strength concrete
30. Performance of epoxy-coated rebars in bridge decks
31. Calibration of design code for buildings (ACI 318): Part 2—Reliability analysis and resistance factors
32. Tamuzs V. and Tepfers R. (1995). “Non-metallic (FRP) reinforcement for concrete structures.” Proc. Int. RILEM Symp. Ghent Belgium 18–25.
33. 10.1061/(ASCE)ST.1943-541X.000019910.1061/(ASCE)ST.1943-541X.0000199 ↗
34. 10.1061/(ASCE)CC.1943-5614.000019710.1061/(ASCE)CC.1943-5614.0000197 ↗
35. 10.1088/0964-1726/19/2/02501110.1088/0964-1726/19/2/025011 ↗
36. Tensile facture and bond properties of ductile hybrid FRP reinforcing bars
37. 10.1061/(ASCE)0733-9445(2006)132:8(1320)10.1061/(ASCE)0733-9445(2006)132:8(1320) ↗