journal article·2013-10

Strength Reduction Factor for Flexural RC Members Strengthened with Near-Surface-Mounted Bars

Hany Jawaheri Zadeh, Felipe Mejia, Antonio Nanni

Publisher page

Abstract

Current American Concrete Institute (ACI) guidelines for the design of flexural RC members strengthened with externally bonded fiber-reinforced polymer (FRP) systems assign an additional partial strength reduction factor to the contribution of FRP, marking a deviation from ACI’s approach in building codes. This conservative method finds its rationale in the novelty and the higher variability of FRP, because of its nature as a material (compared to steel) and the conditions of its installation (externally bonded). Using the case of near-surface-mounted (NSM) FRP bars, this paper demonstrates that a single strength reduction factor can be formulated, while maintaining the same reliability and safety required in conventional RC members. Using a comprehensive test matrix of flexural members processed with a computerized Monte Carlo simulation technique, the probabilistic implications of strengthening RC beams and slabs with NSM FRP bars are investigated. The generated statistical data are employed to recommend revised strength reduction factors for flexural RC members strengthened with NSM FRP bars that eliminate the partial factor, and yet, provide a safety level equal to ordinary steel RC members.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Load-Bearing Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Dept. of Civil, Architectural, and Environmental Engineering, Univ. of Miami (UM-CAE), 103 McArthur Engineering Bldg., Coral Gables, FL 33146-0630 (corresponding author).

Dept. of Civil, Architectural, and Environmental Engineering, Univ. of Miami (UM-CAE), 103 McArthur Engineering Bldg., Coral Gables, FL 33146-0630.

Lester and Gwen Fisher Endowed Scholar, Professor, Dept. of Civil, Architectural, and Environmental Engineering, Univ. of Miami (UM-CAE), 103 McArthur Engineering Bldg., Coral Gables, FL 33146-0630; and Professor, Dept. of Structural Engineering, Univ. of Naples, Federico II, Via Claudio 21, Naples, P.O. Box I-80125, Italy.

References (15)

Show source-provided references
1. ACI Committee. (2006). “Guide for the design and construction of structural concrete reinforced with FRP bars.” 440.1R American Concrete Institute (ACI) Farmington Hills MI.
2. ACI Committee. (2008). “Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures.” 440.2R American Concrete Institute Farmington Hills MI.
3. ACI Committee. (2011). “Building code requirements for structural concrete.” ACI 318-11 American Concrete Institute (ACI) Farmington Hills MI.
4. Castro E. Melo G. and Nagato Y. (2007). “Flexural strengthening of RC T beams with near surface mounted FRP reinforcements.” Proc. of the 8th Int. Symp. on Fiber Reinforced Polymers for Reinforced Concrete Structures Univ. of Patras Patras.
5. 10.1016/j.conbuildmat.2010.03.00810.1016/j.conbuildmat.2010.03.008 ↗
6. De Lorenzis L. Nanni A. and La Tegola A. (2000). “Flexural and shear strengthening of reinforced concrete structures with near surface mounted FRP rods.” Proc. 3rd Int. Conf. on Advanced Composite Materials in Bridges and Structures (ACMBS III) 521–528.
7. Near-surface-mounted fiber-reinforced polymer reinforcements for flexural strengthening of concrete structures
8. Ellingwood B. Galambos T. V. MacGregor J. G. and Cornell C. A. (1980). “Development of a p robability b ased l oad v riterion for American National Standard A58.” NBS Special Rep. 577 US Department of Commerce National Bureau of Standards Washington DC.10.6028/NBS.SP.577 ↗
9. Gulbrandsen P. (2005). “Reliability analysis of the flexural capacity of fiber reinforced polymer bars in concrete beams.” M.Sc thesis University of Minnesota St. Paul MN.
10. Haldar A. · 2000
11. Hicks C. · 1999
12. Jawaheri Zadeh H. and Nanni A. (2012). “Reliability analysis of concrete beams internally reinforced with FRP bars.” ACI Struct. J. in press.ASTJEG0889-3241
13. Nowak A. S. · 2000
14. Calibration of design code for buildings (ACI 318): Part 1—Statistical models for resistance
15. Calibration of design code for buildings (ACI 318): Part 2—Reliability analysis and resistance factors