Relevance of pore network connectivity in tannin-derived carbons for rapid detection of BTEX traces in indoor air
Source abstract
Abstract
Abstract This study showcases the exceptional detection capabilities of a silicon-based micro-analytical device engineered to identify low concentrations of BTEX (benzene, toluene, ethylbenzene, and xylene) in indoor air, with a focus on the critical role of connectivity within the adsorbent material. Two micro-mesoporous carbons were synthesized using an eco-friendly method, differing primarily in their mesoporosity: one with an ordered structure (OMC) and the other with a disordered, interconnected porous network (DMC). The high pore connectivity of the DMC significantly enhanced BTEX accessibility to micropores, leading to superior preconcentration and detection performance, even under realistic conditions with 60% relative humidity at 25°C. The DMC-based system achieved the detection of BTEX compounds at ppb levels within a short analysis time (∼10 min), demonstrating the importance of pore network connectivity in the adsorption process. This study underscores the potential of DMC as a highly efficient adsorbent for detecting volatile organic compounds in challenging indoor environments, where high connectivity within the porous structure is key to achieving outstanding performance.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Chemical Sensor Technologies · Indoor Air Quality and Microbial Exposure · Polydiacetylene-based materials and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Université Marie et Louis Pasteur, CNRS, institut FEMTO-ST , F-25000, Doubs , Besançon , France
Université de Lorraine, CNRS, IJL , F-88000, Vosges , Épinal , France
Institut Universitaire de France (IUF) , F-75231 , Paris , France
References (24)
Show source-provided references
1. Loomis, D., K. Z. Guyton, Y. Grosse, F. El Ghissassi, V. Bouvard, L. Benbrahim-Tallaa, et al. Carcinogenicity of benzene. The Lancet Oncology(London), Vol. 18, 2017, pp. 1574–1575.10.1016/S1470-2045(17)30832-X ↗
2. Raysoni, A. U., T. H. Stock, J. A. Sarnat, M. C. Chavez, S. E. Sarnat, T. Montoya, et al. Evaluation of VOC concentrations in indoor and outdoor microenvironments at near-road schools. Environmental Pollution, Vol. 231, 2017, pp. 681–693.10.1016/j.envpol.2017.08.065 ↗
3. Parra, M. A., D. Elustondo, R. Bermejo, and J. M. Santamaría. Quantification of indoor and outdoor volatile organic compounds (VOCs) in pubs and cafés in Pamplona, Spain. Atmospheric Environment, Vol. 42, 2008, pp. 6647–6654.10.1016/j.atmosenv.2008.04.026 ↗
4. Zhong, L., F. C. Su, and S. Batterman. Volatile organic compounds (VOCs) in conventional and high performance school buildings in the U.S. International Journal of Environmental Research and Public Health, Vol. 14, No. 1, 2017, id. 100.10.3390/ijerph14010100 ↗
5. Lara-lbeas, I., A. Rodríguez-Cuevas, C. Andrikopoulou, V. Person, L. Baldas, S. Colin, et al. Sub-ppb level detection of BTEX gaseous mixtures with a compact prototype GC equipped with a preconcentration unit. Micromachines, Vol. 10, 2019, id. 187.10.3390/mi10030187 ↗
6. Sun, J., N. Xue, W. Wang, H. Wang, C. Liu, T. Ma, et al. Compact prototype GC-PID system integrated with micro PC and micro GC column. Journal of Micromechanics and Microengineering, Vol. 29, 2019, id. 035008.10.1088/1361-6439/aaf42c ↗
7. Chappuis, T. H., B. A. P. Ho, M. Ceillier, F. Ricoul, M. Alessio, J. F. Beche, et al. Miniaturization of breath sampling with silicon chip: application to volatile tobacco markers tracking. Journal of Breath Research, Vol. 12, 2018, id. 046011.10.1088/1752-7163/aad384 ↗
8. You, D. W., Y. S. Seon, Y. Jang, J. Bang, J. S. Oh, and K. W. Jung. A portable gas chromatograph for real-time monitoring of aromatic volatile organic compounds in air samples. Journal of Chromatography A, Vol. 1625, 2020, id. 461267.10.1016/j.chroma.2020.461267 ↗
9. Megías-Sayago, C., I. Lara-Ibeas, Q. Wang, S. Le Calvé, and B. Louis. Volatile organic compounds (VOCs) removal capacity of ZSM-5 zeolite adsorbents for near real-time BTEX detection. Journal of Environmental Chemical Engineering, Vol. 8, 2020, id. 103724.10.1016/j.jece.2020.103724 ↗
10. Dizbay-Onat, M., E. Floyd, U. K. Vaidya, and C. T. Lungu. Applicability of industrial sisal fiber waste derived activated carbon for the adsorption of volatile organic compounds (VOCs). Fibers and Polymers, Vol. 19, 2018, pp. 805–811.10.1007/s12221-018-7866-z ↗
11. Isinkaralar, K., G. Gullu, and A. Turkyilmaz. Optimal preparation of low-cost activated carbon: the enhanced mechanism of interaction and performance studies for volatile organic compounds (VOCs) capture. Biomass Conversion and Biorefinery, Vol. 13, 2023, pp. 4279–4289.
12. El Mohajir, A., J. Castro-Gutiérrez, R. Luan Sehn Canevesi, I. Bezverkhyy, G. Weber, J. P. Bellat, et al. Novel porous carbon material for the detection of traces of volatile organic compounds in indoor air. ACS Applied Materials & Interfaces, Vol. 13, No. 33, 2021, pp. 40088–40097.10.1021/acsami.1c10430 ↗
13. Castro-Gutiérrez, J., A. Sanchez-Sanchez, J. Ghanbaja, N. Díez, M. Sevilla, A. Celzard, et al. Synthesis of perfectly ordered mesoporous carbons by water-assisted mechanochemical self-assembly of tannin. Green Chemistry, Vol. 20, 2018, pp. 5123–5132.10.1039/C8GC02295J ↗
14. Castro-Gutiérrez, J., E. De Oliveira Jardim, R. L. S. Canevesi, J. Silvestre-Albero, M. Kriesten, M. Thommes, et al. Molecular sieving of linear and branched C6 alkanes by tannin-derived carbons. Carbon, Vol. 174, 2021, pp. 413–422.10.1016/j.carbon.2020.12.061 ↗
15. Thommes, M., K. Kaneko, A. V. Neimark, J. P. Olivier, F. Rodriguez-Reinoso, J, Rouquerol, et al. Physisorption of gases, with special reference to the evaluation of surface area and pore size distribution (IUPAC Technical Report). Pure and Applied Chemistry. Chimie pure et appliquée, Vol. 87, 2015, pp. 1051–1069.10.1515/pac-2014-1117 ↗
16. Gregis, G., J. B. Sanchez, I. Bezverkhyy, G. Weber, F. Berger, V. Fierro, et al. Detection and quantification of lung cancer biomarkers by a micro-analytical device using a single metal oxide-based gas sensor. Sensors and Actuators B, Chemical, Vol. 255, 2018, pp. 391–400.10.1016/j.snb.2017.08.056 ↗
17. Pujol, Q., G. Weber, J. P. Bellat, S. Gratz, A. Krusenbaum, L. Borchardt, et al. Potential of novel porous materials for capture of toluene traces in air under humid conditions. Microporous and Mesoporous Materials, Vol. 344, 2022, id. 112204.10.1016/j.micromeso.2022.112204 ↗
18. Zhao, W., V. Fierro, N. Fernandez-Huerta, M. T. Izquierdo, and A. Celzard. Impact of synthesis conditions of KOH activated carbons on their hydrogen storage capacities. International Journal of Hydrogen Energy, Vol. 37, 2012, pp. 14278–14284.10.1016/j.ijhydene.2012.06.110 ↗
19. Kaikiti, C., M. Stylianou, and A. Agapiou. TD-GC/MS analysis of indoor air pollutants (VOCs, PM) in hair salons. Chemosphere, Vol. 294, 2022, id. 133691.10.1016/j.chemosphere.2022.133691 ↗
20. Yang, K., Q. Sun, F. Xue, and D. Lin. Adsorption of volatile organic compounds by metal–organic frameworks MIL-101: Influence of molecular size and shape. Journal of Hazardous Materials, Vol. 195, 2011, pp. 124–131.10.1016/j.jhazmat.2011.08.020 ↗
21. Frausto-Vicencio, I., A. Moreno, H. Goldsmith, Y. K. Hsu, and F. M. Hopkins. Characterizing the performance of a compact BTEX GC-PID for near-real time analysis and field deployment. Sensors, Vol. 21, 2021, id. 2095.10.3390/s21062095 ↗
22. Tzeng, T. H., C. Y. Kuo, S. Y. Wang, P. K. Huang, Y. M. Huang, and W. C. Hsieh. A portable micro gas chromatography system for lung cancer associated volatile organic compound detection. IEEE Journal of Solid-State Circuits, Vol. 51, 2016, pp. 259–272.10.1109/JSSC.2015.2489839 ↗
23. Skog, K. M., F. Xiong, H. Kawashima, E. Doyle, R. Soto, and D. R. Gentner. Compact, automated, inexpensive, and field-deployable vacuum-outlet gas chromatograph for trace-concentration gas-phase organic compounds. Analytical Chemistry, Vol. 91, No. 2, 2019, pp. 1318–1327.10.1021/acs.analchem.8b03095 ↗
24. Rodríguez-Cuevas, A., I. Lara-Ibeas, A. Leprince, M. Wolf, and S. Le Calvé. Easy-to-manufacture micro gas preconcentrator integrated in a portable GC for enhanced trace detection of BTEX. Sensors and Actuators B, Chemical, Vol. 324, 2020, id. 128690.10.1016/j.snb.2020.128690 ↗