The U.S. Interstate 80 bridge over State Street in Salt Lake City is very near the Wasatch fault, which is active and capable of producing large earthquakes. The bridge was designed and built in 1965 according to the 1961 American Association of State Highway Officials specifications, which did not consider earthquake-induced forces or displacements. The bridge consists of reinforced concrete bents supporting steel plate welded girders. The bents are supported on cast-in-place concrete piles and pile caps. A seismic retrofit design was developed using carbon fiber reinforced polymer (CFRP) composites, which was implemented in the summer of 2000 and the summer of 2001, to improve the displacement ductility of the bridge. The seismic retrofit included column jacketing, as well as wrapping of the bent cap and bent cap-column joints for confinement, flexural, and shear strength increase. This paper describes the specifications developed for the CFRP composite column jackets and composite bent wrap. The specifications included provisions for materials, constructed thickness based on strength capacity, and an environmental durability reduction factor. Surface preparation, finish coat requirements, quality assurance provisions, which included sampling and testing, and constructability issues regarding the application of fiber composite materials in the retrofit of concrete bridges are also described.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Professor, Dept. of Civil and Environmental Engineering, 122 South Campus Drive, Suite 104 EMRO, Univ. of Utah, Salt Lake City, UT 84112 (corresponding author).

President, Navlight Composites, Pasadena, CA 91107.

President, Frederick Policelli & Associates, Salt Lake City, UT 84117.

References (20)

Show source-provided references
1. American Concrete Institute (ACI). (1996). “State-of-the-art report on fiber reinforced plastic reinforcement for concrete structures.” Rep. ACI Committee 440 Detroit.
2. American Concrete Institute (ACI). (2000). “State-of-the-art report on fiber-reinforced plastic reinforcement for concrete structures.” Rep. ACI Committee 440 Detroit.
3. American Concrete Institute (ACI). (2002). “Guide for the design and construction of externally bonded FRP systems for stengthening concrete structures.” Rep. ACI 440.2R-02 Farmington Hills Mich.
4. 10.1061/(ASCE)1090-0268(2000)4:1(3)10.1061/(ASCE)1090-0268(2000)4:1(3) ↗
5. Clarke J. L. O’Regan D. P. and Thirugnanendran C. (1996). “EUROCRETE project: Modification of design rules to incorporate non-ferrous reinforcement.” EUROCRETE Project Rep. Sir William Halcrow & Partners London.
6. Gamble W. L. and Hawkins N. M. (1996). “Seismic retrofitting of bridge pier columns.” Proc. Structures Congress XIV ASCE Reston Va. 1 16–23.
7. 10.1061/(ASCE)1090-0268(1998)2:4(165)10.1061/(ASCE)1090-0268(1998)2:4(165) ↗
8. International Conference of Building Officials Evaluation Service (ICBO). (2001). “Acceptance criteria for concrete and reinforced and unreinforced masonry strengthening using fiber-reinforced polymer (FRP) composite systems.” ICBO Rep. No. AC125 Whittier Calif.
9. Japan Society of Civil Engineers (JSCE). (1997). “Recommendations for design and construction of concrete structures using continuous fiber reinforcing materials.” Concrete Engineering Series 23 A. Machida ed. Tokyo Japan.
10. Katsuki F. and Uomoto T. (1995). “Prediction of deterioration of FRP rods due to alkali attack.” Proc. 2nd Int. Symp. on Nonmetallic (FRP) Reinforcement for Concrete Structures (FRPRCS-2) E&FN Spon London 82–89.
11. Pantelides C. P. Alameddine F. Sardo T. Okahashi Y. and Moran D. (2001a). “Seismic rehabilitation of State Street bridge.” Proc. 9th Int. Conf. and Exhibition Structural Faults and Repair Engineering Technics Press Edinburgh U.K.
12. Pantelides C. P. Duffin J. B. Ward J. Delahunty C. and Reaveley L. D. (2002). “In-situ tests at South Temple bridge on Interstate 15.” Proc. 7th U.S. National Conference on Earthquake Engineering Earthquake Engineering Research Institute EL Cerrito Calif.
13. 10.1193/1.158618610.1193/1.1586186 ↗
14. 10.1061/(ASCE)0733-9445(1999)125:10(1094)10.1061/(ASCE)0733-9445(1999)125:10(1094) ↗
15. Priestley M. J. N. Seible F. and Calvi G. M. (1996). Seismic design and retrofit of bridges Wiley New York.10.1002/9780470172858 ↗
16. Seible F. Hegemier G. Policelli F. Karbhari V. Randolph R. and Belknap F. (1995). “Earthquake retrofit of bridge columns with continuous carbon fiber jacket.” Advanced Composite Technology Transfer Consortium/Bridge Infrastructure Renewal Rep. No. ACTT-95/07 DARPA Univ. of California at San Diego La Jolla Calif. I–IV.
17. 10.1061/(ASCE)1090-0268(1997)1:2(52)10.1061/(ASCE)1090-0268(1997)1:2(52) ↗
18. Tannous F. E. (1997). “Durability of non-metallic reinforcing bars and prestressing tendons.” PhD dissertation Dept. of Civil Engineering and Engineering Mechanics Univ. of Arizona Tucson Ariz.
19. 10.1061/(ASCE)1090-0268(1999)3:1(38)10.1061/(ASCE)1090-0268(1999)3:1(38) ↗
20. Utah Department of Transportation (UDOT). (1999). “Supplemental specifications—Special provisions.” Rep. I-80 Bridge Rehabilitation Project No. IM-80-3(126)123 Salt Lake City Utah Section 525S 121–143 Section 526S.