journal article·2020-01-01

Proposed Slenderness Limit for Glass Fiber-Reinforced Polymer-Reinforced Concrete Columns Based on Experiments and Buckling Analysis

Authors not provided

ACI Structural Journal· Volume 117· Issue 1
Publisher page

Abstract

First Name is required invalid characters Last Name is required invalid characters Email Address is required Invalid Email Address Invalid Email Address
Only a short abstract or summary was supplied by the source.
Source: openalex_inverted_index · Quality: short

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (33)

Show source-provided references
1. ACI Committee 318, 2014, “Building Code Requirements for Structural Concrete (ACI 318-14) and Commentary (ACI 318R-14),” American Concrete Institute, Farmington Hills, MI, 519 pp.
2. ACI Committee 440, 2015, “Guide for the Design and Construction of Structural Concrete Reinforced with FRP Bars (ACI 440.1R-15),” American Concrete Institute, Farmington Hills, MI, 88 pp.
3. Afifi, M. Z.; Mohamed, H. M.; and Benmokrane, B., 2014, “Axial Capacity of Circular Concrete Columns Reinforced with GFRP Bars and Spirals,” Journal of Composites for Construction, ASCE, V. 18, No. 1, Feb., p. 04013017. doi: 10.1061/(ASCE)CC.1943-5614.000043810.1061/(ASCE)CC.1943-5614.0000438 ↗
4. ASTM D2584-08, 2008, “Standard Test Method for Ignition Loss of Cured Reinforced Resins,” ASTM International, West Conshohocken, PA, 3 pp.
5. ASTM C39/C39M-17b, 2017, “Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens,” ASTM International, West Conshohocken, PA, 8 pp.
6. Bažant, Z. P.; Cedolin, L.; and Tabbara, M. R., 1991, “New Method of Analysis for Slender Columns,” ACI Structural Journal, V. 88, No. 4, July-Aug., pp. 391-401.10.14359/2679 ↗
7. Canadian Standards Association (CSA), 2012, “Design and Construction of Building Components with Fiber Reinforced Polymers (CAN/CSAS806-12),” CSA Group, Mississauga, ON, Canada, 198 pp.
8. Canadian Standards Association (CSA), 2014, “Design of Concrete Structures (CSA A23.3-14),” CSA Group, Rexdale, ON, Canada, 298 pp.
9. De Luca, A.; Matta, F.; and Nanni, A., 2010, “Behavior of Full-Scale Glass Fiber-Reinforced Polymer Reinforced Concrete Columns under Axial Load,” ACI Structural Journal, V. 107, No. 5, Sept.-Oct., pp. 589-596.10.14359/51663912 ↗
10. Engesser, F., 1889, “Uber die Knickfestigkeit gerader Stabe,” Zeitschrift fur Architektur und lngenieurwesen, V. 35 (Section 8.1).
11. Guérin, M.; Mohamed, H. M.; Benmokrane, B.; Shield, C. K.; and Nanni, A., 2018, “Effect of Glass Fiber-Reinforced Polymer Reinforcement Ratio on Axial-Flexural Strength of Reinforced Concrete Columns,” ACI Structural Journal, V. 115, No. 4, July, pp. 1049-1061. doi: 10.14359/5170127910.14359/51701279 ↗
12. Hadhood, A.; Mohamed, H. M.; and Benmokrane, B., 2017a, “Axial Load-Moment Interaction Diagram of Circular Concrete Columns Reinforced with CFRP Bars and Spirals: Experimental and Theoretical Investigations,” Journal of Composites for Construction, ASCE, V. 21, No. 2, Jan., p. 04016092. doi: 10.1061/(ASCE)CC.1943-5614.000074810.1061/(ASCE)CC.1943-5614.0000748 ↗
13. Hadhood, A.; Mohamed, H. M.; and Benmokrane, B., 2017b, “Experimental Study of Circular High-Strength Concrete Columns Reinforced with GFRP Bars and Spirals under Concentric and Eccentric Loading,” Journal of Composites for Construction, ASCE, V. 21, No. 2, Jan., p. 04016078. doi: 10.1061/(ASCE)CC.1943-5614.000073410.1061/(ASCE)CC.1943-5614.0000734 ↗
14. Hadhood, A.; Mohamed, H. M.; and Benmokrane, B., 2017d, “Strength of Circular HSC Columns Reinforced Internally with Carbon-Fiber-Reinforced Polymer Bars under Axial and Eccentric Loads,” Construction and Building Materials, V. 141, pp. 366-378. doi: 10.1016/j.conbuildmat.2017.02.11710.1016/j.conbuildmat.2017.02.117 ↗
15. Hadhood, A.; Mohamed, H. M.; Benmokrane, B.; Nanni, A.; and Shield, C. K., 2019, “Assessment of Design Guidelines of Concrete Columns Reinforced with Glass Fiber-Reinforced Polymer Bars,” ACI Structural Journal, V. 116, No. 4, July, pp. 193-207. doi: 10.14359/5171566310.14359/51715663 ↗
16. Hadhood, A.; Mohamed, H. M.; Ghrib, F.; and Benmokrane, B., 2017c, “Efficiency of Glass-Fiber Reinforced-Polymer (GFRP) Discrete Hoops and Bars in Concrete Columns under Combined Axial and Flexural Loads,” Composites. Part B, Engineering, V. 114, No. 6, pp. 223-236. doi: 10.1016/j.compositesb.2017.01.06310.1016/j.compositesb.2017.01.063 ↗
17. Hadi, M. N.; Karim, H.; and Sheikh, M. N., 2016, “Experimental Investigations on Circular Concrete Columns Reinforced with GFRP Bars and Helices under Different Loading Conditions,” Journal of Composites for Construction, ASCE, V. 20, No. 4, p. 04016009. doi: 10.1061/(ASCE)CC.1943-5614.000067010.1061/(ASCE)CC.1943-5614.0000670 ↗
18. Hales, T. A.; Pantelides, C. P.; and Reaveley, L. D., 2016, “Experimental Evaluation of Slender High-Strength Concrete Columns with GFRP and Hybrid Reinforcement,” Journal of Composites for Construction, ASCE, V. 20, No. 6, Dec., p. 04016050 doi: 10.1061/(ASCE)CC.1943-5614.000070910.1061/(ASCE)CC.1943-5614.0000709 ↗
19. MacGregor, J. G.; Breen, J. E.; and Pfrang, E. O., 1970, “Design of Slender Concrete Columns,” ACI Journal Proceedings, V. 67, No. 1, Jan., pp. 6-28.10.14359/7254 ↗
20. Maranan, G. B.; Manalo, A. C.; Benmokrane, B.; Karunasena, W.; and Mendis, P., 2016, “Behavior of Concentrically Loaded Geopolymer-Concrete Circular Columns Reinforced Longitudinally and Transversely with GFRP Bars,” Engineering Structures, V. 117, No. 15, June, pp. 422-436. doi: 10.1016/j.engstruct.2016.03.03610.1016/j.engstruct.2016.03.036 ↗
21. Mirmiran, A.; Shahawy, M.; and Beitleman, T., 2001b, “Slenderness Limit for Hybrid FRP Concrete Columns,” Journal of Composites for Construction, ASCE, V. 5, No. 1, Feb., pp. 26-34. doi: 10.1061/(ASCE)1090-0268(2001)5:1(26)10.1061/(ASCE)1090-0268(2001)5:1(26) ↗
22. Mirmiran, A.; Yuan, W.; and Chen, X., 2001a, “Design for Slenderness in Concrete Columns Internally Reinforced with Fiber-Reinforced Polymer Bars,” ACI Structural Journal, V. 98, No. 1, Jan.-Feb., pp. 116-125.10.14359/10153 ↗
23. Mohamed, H. M.; Abdel-Baky, H.; and Masmoudi, R., 2010, “Nonlinear Stability Analysis of Concrete Filled Fiber-Reinforced Polymer-Tube Columns: Experimental and Theoretical Investigation,” ACI Structural Journal, V. 107, No. 6, Nov.-Dec., pp. 699-708.10.14359/51664018 ↗
24. Mohamed, H. M.; Afifi, M. Z.; and Benmokrane, B., 2014, “Performance Evaluation of Concrete Columns Reinforced Longitudinally with FRP Bars and Confined with FRP Hoops and Spirals under Axial Load,” Journal of Bridge Engineering, ASCE, V. 19, No. 7, June, p. 04014020. doi: 10.1061/(ASCE)BE.1943-5592.000059010.1061/(ASCE)BE.1943-5592.0000590 ↗
25. Pantelides, C. P.; Gibbons, M. E.; and Reaveley, L. D., 2013, “Axial Load Behavior of Concrete Columns Confined with GFRP Spirals,” Journal of Composites for Construction, ASCE, V. 17, No. 3, June, pp. 305-313. doi: 10.1061/(ASCE)CC.1943-5614.000035710.1061/(ASCE)CC.1943-5614.0000357 ↗
26. Popovics, S., 1973, “A Numerical Approach to the Complete Stress-Strain Curve of Concrete,” Cement and Concrete Research, V. 3, No. 5, Sep., pp. 583-599. doi: 10.1016/0008-8846(73)90096-310.1016/0008-8846(73)90096-3 ↗
27. Shanley, F. R., 1947, “Inelastic Column Theory,” Journal of the Aeronautical Sciences, V. 14, No. 5, May, pp. 261-268. doi: 10.2514/8.134610.2514/8.1346 ↗
28. Sheikh, S. A., and Kharal, Z., 2018, “Replacement of Steel with GFRP for Sustainable Reinforced Concrete,” Construction and Building Materials, V. 160, pp. 767-774. doi: 10.1016/j.conbuildmat.2017.12.14110.1016/j.conbuildmat.2017.12.141 ↗
29. Tobbi, H.; Farghaly, A. S.; and Benmokrane, B., 2012, “Concrete Columns Reinforced Longitudinally and Transversally with GFRP Bars,” ACI Structural Journal, V. 109, No. 4, July-Aug., pp. 551-558.10.14359/51683874 ↗
30. Xue, W.; Peng, F.; and Fang, Z., 2018, “Behavior and Design of Slender Rectangular Concrete Columns Longitudinally Reinforced with Fiber-Reinforced Polymer Bars,” ACI Structural Journal, V. 115, No. 2, Mar., pp. 311-322. doi: 10.14359/5170113110.14359/51701131 ↗
31. Youssef, J., and Hadi, M. N., 2017, “Axial Load-Bending Moment Diagrams of GFRP Reinforced Columns and GFRP Encased Square Columns,” Construction and Building Materials, V. 135, pp. 550-564. doi: 10.1016/j.conbuildmat.2016.12.12510.1016/j.conbuildmat.2016.12.125 ↗
32. Zadeh, H. J., and Nanni, A., 2013, “Design of RC Columns Using Glass FRP Reinforcement,” Journal of Composites for Construction, ASCE, V. 17, No. 3, pp. 294-304. doi: 10.1061/(ASCE)CC.1943-5614.000035410.1061/(ASCE)CC.1943-5614.0000354 ↗
33. Zadeh, H. J., and Nanni, A., 2017, “Flexural Stiffness and Second-Order Effects in Fiber-Reinforced Polymer-Reinforced Concrete Frames,” ACI Structural Journal, V. 114, No. 2, Mar.-Apr., pp. 533-544. doi: 10.14359/5168925710.14359/51689257 ↗