Abstract

Analytical formulas for optimal selection of the values of the main parameters of a multichannel continuously scanning digital X-ray radiography system, which is based on a linear detector array, and the minimum required value of the exposure dose rate from an X-ray source are obtained using the specified values of the system’s spatial resolution in the “worst case” and the testing capacity taking the digital filtering of the radiation detection results into account.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Digital Radiography and Breast Imaging · Radiation Detection and Scintillator Technologies · Advanced X-ray and CT Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (17)

Show source-provided references
1. Klyuev, V.V. and Sosnin, F.R., Modern Radiation NDT Systems, Defektoskopiya, 1993, no. 1, pp. 65–71.
2. Klyuev, V.V. and Sosnin, F.R., Modern State of Digital X-ray Engineering, Defektoskopiya, 1999, no. 4, pp. 56–66.
3. Sosnin, F.R., Modern Methods and Tools of Digital X-ray Radiography, Zavod. Lab. 1994, vol. 60, no. 6, pp. 28–34.
4. Baru, S.E., Safe X-ray Radiography, Nauka Ross., 1997, no. 4, pp. 12–16.
5. Belova, I.B. and Kitaev, V.M., Digital Technologies for Obtaining X-ray Images: Principle of Formation and Types (Review), Medits. Vizual., 2000, no. 1, pp. 33–40.
6. Nedavnii, O.I. and Udod, V.A., Modern State of Digital X-ray Radiography Systems (Review), Defektoskopiya, 2001, no. 8, pp. 62–82.
7. Halmshaw, R., Analysis of the Performance of X-ray Television-Fluoroscopic Equipment in Weld Inspection, Mater. Eval., 1987, vol. 45, no. 11, pp. 1289–1302.
8. Lebedev, M.B., Sidulenko, O.A., and Udod, V.A., Analysis of Modern State and Development of Digital X-ray Radiography Systems, Izv. Tomsk. Politekh. Univer., 2008, vol. 312, no. 2, pp. 47–55.
9. Yaffe, M.J. and Rowlands, J.A., X-ray Detectors for Digital Radiography (Review), Phys. Med. Biol., 1997, vol. 42, no. 1, pp. 1–39.10.1088/0031-9155/42/1/001 ↗
10. Gusev, E.A., Firstov, V.G., Petushkov, A.A., et al., A Scanning X-ray Introscope with a 1D Matrix Transducer Based on Silicon Photodetectors, Defektoskopiya, 1989, no. 7, pp. 38–42.
11. Lebedev, M.B., Sidulenko, O.A., and Udod, V.A., Optimal Selection of Parameters of Multichannel Continuously Scanning Digital Radiography Systems, Defektoskopiya, 2009, no. 10, pp. 58–77 [Russ. J. Nondestr. Test. (Engl. Transl.), 2009, vol. 45, no. 10, pp. 711–727].10.1134/S1061830909100064 ↗
12. Dadzhion, D. and Mersero, R., Tsifrovaya obrabotka mnogomernykh signalov (Digital Processing of Multidimensional Signals), Moscow: Mir, 1988.
13. Leonov, B.I., Sosnin, F.R., and Valuev, N.P., Nerazrushayushchii kontrol’ (Nondestructive Testing), Moscow: Znanie, 1985, p. 64.
14. Dobromyslov, V.A. and Rumyantsev, S.V., Radiatsionnaya introskopiya (Radiation Introscopy), Moscow: Atomizdat, 1972.
15. Lebedev, M.B., Sidulenko, O.A., and Udod, V.A., A Mathematical Model of Multichannel Continuously Scanning Digital Radiography Systems, Defektoskopiya, 2007, no. 6, pp. 65–72 [Russ. J. Nondestr. Test. (Engl. Transl.), 2007, vol. 43, no. 6, pp. 401–406].10.1134/S1061830907060083 ↗
16. Lebedev, M.B., Sidulenko, O.A., and Udod, V.A., Selection of Parameters of Multichannel Continuously Scanning Digital Radiography Systems, Kontr. Diagnost., 2007, no. 12, pp. 17–26.
17. Lebedev, M.B., Sidulenko, O.A., and Udod, V.A., Consideration of Digital Filtering During Selection of Parameters of Multichannel Continuously Scanning Digital X-ray Radiography Systems, Defektoskopiya, 2008, no. 1, pp. 3–18. [Russ. J. Nondestr. Test. (Engl. Transl.), 2008, vol. 44, no. 1, pp. 1–14].10.1134/S1061830908010014 ↗