journal article·2000-04

Elimination of spurious signal due to misalignment of magnetic axes in a differential magnetic-modulation transducer: Part II. Experimental

V. I. Pudov

Publisher page

Abstract

The efficiency of compensation for spurious signals from a primary differential magnetic-modulation transducer (ferromagnetic probe) as a function of operating parameters of a compensating component is discussed. Given an appropriate choice of the material, length, shape, diameter, and location with respect to the magnetically sensitive element, one can reduce spurious signals from the magnetic-modulation transducer due to the transverse component of the earth magnetic field by a factor of 15 to 20.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Electric Power Systems and Control · Advanced Scientific Research Methods · Sensor Technology and Measurement Systems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (5)

Show source-provided references
1. Pudov, V.I., Elimination of Spurious Signal due to Misalignment of Magnetic Axes in a Differential Magnetic-Modulation Transducer. Part I,Defektoskopiya, 2000, no. 4, pp. 18–27 (this issue).
2. Pudov, V.I., Balancing Differential Magnetic-Field Gradient Transducer,Defektoskopiya, 1997, no. 11, pp. 54–57.
3. Splavy pretsizionnye magnitomyagkie (Precision Magnetically Soft Alloys), GOST (State Standard) 10160-90, Moscow: Gosstandart SSSR.
4. Pudov, V.I., Reutov, Yu.Ya., and Kulikov, V.A., Instrument for Localization of Foreign Ferromagnetic Bodies in an Eye and Its Socket, RF Patent no. 2090137,Byull. Izobr., 1997, no. 26, p. 285.
5. Pudov, V.I., Reutov, Yu.Ya., Vedenev, M.A., and Kulikov, V.A., Technique for Balancing a Ferromagnetic Transducer with Two Coaxial Sensitive Elements, RF Patent no. 2053712,Byull. Izobr., 1996, no. 4, p. 143.