Cryogenic Interlaminar Fracture Properties of Woven Glass/Epoxy Composite Laminates Under Mixed-Mode I/III Loading Conditions
Source abstract
Abstract
We characterize the combined Mode I and Mode III delamination fracture behavior of woven glass fiber reinforced polymer (GFRP) composite laminates at cryogenic temperatures. The eight-point bending plate (8PBP) tests were conducted at room temperature, liquid nitrogen temperature (77 K) and liquid helium temperature (4 K) using a new test fixture. A three-dimensional finite element analysis was also performed to calculate the energy release rate distribution along the delamination front, and the delamination fracture toughnesses were evaluated for various mixed-mode I/III ratios. Furthermore, the microscopic examinations of the fracture surfaces were carried out with scanning electron microscopy (SEM), and the mixed-mode I/III delamination fracture mechanisms in the woven GFRP laminates at cryogenic temperatures were assessed. The fracture properties were then correlated with the observed characteristics.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Mechanical Behavior of Composites · Fatigue and fracture mechanics · Mechanical stress and fatigue analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (18)
Show source-provided references
1. Shindo, Y., Horiguchi, K., Wang, R., Kudo, H.: Double cantilever beam measurement and finite element analysis of cryogenic mode I interlaminar fracture toughness of glass-cloth/epoxy laminates. ASME J. Eng. Mater. Technol. 123, 191–197 (2001)10.1115/1.1345527 ↗
2. Horiguchi, K., Shindo, Y., Kudo, H., Kumagai, S.: End-notched flexure testing and analysis of mode II interlaminar fracture behavior of glass-cloth/epoxy laminates at cryogenic temperatures. J. Compos. Technol. Res. 24(4), 239–245 (2002)10.1115/1.1345527 ↗
3. Shindo, Y., Sato, T., Narita, F., Sanada, K.: Mode II interlaminar fracture and damage evaluation of GFRP woven laminates at cryogenic temperatures using the 4ENF specimen. J. Compos. Mater. 42(11), 1089–1101 (2008)10.1177/0021998308090451 ↗
4. Rizov, V., Shindo, Y., Horiguchi, K., Narita, F.: Mode III interlaminar fracture behavior of glass fiber reinforced polymer woven laminates at 293 to 4 K. Appl. Compos. Mater. 13, 287–304 (2006)10.1007/s10443-006-9008-9 ↗
5. Shindo, Y., Shinohe, D., Kumagai, S., Horiguchi, K.: Analysis and testing of mixed-mode interlaminar fracture behavior of glass-cloth/epoxy laminates at cryogenic temperatures. ASME J. Eng. Mater. Technol. 127, 468–475 (2005)10.1115/1.2019944 ↗
6. Shindo, Y., Takahashi, S., Takeda, T., Narita, F., Watanabe, S.: Mixed-mode interlaminar fracture and damage characterization in woven fabric-reinforced glass/epoxy composite laminates at cryogenic temperatures using the finite element and improved test methods. Eng. Fract. Mech. 75, 5101–5112 (2008)10.1016/j.engfracmech.2008.07.009 ↗
7. Pereira, A.B., de Morais, A.B.: Mixed-mode I + III interlaminar fracture of carbon/epoxy laminates. Compos. Part A Appl. Sci. Manuf. 40, 518–523 (2009)10.1016/j.compositesa.2009.02.003 ↗
8. Hahn, H.T., Pandey, R.: A micromechanics model for thermoelastic properties of plain weave fabric composites. ASME J. Eng. Mater. Technol. 116, 517–523 (1994)10.1115/1.2904322 ↗
9. Shindo, Y., Miura, M., Takeda, T., Narita, F., Watanabe, S.: Piezoelectric control of delamination response in woven fabric composites under mode I loading. Acta Mech. (in press)
10. Miura, M., Shindo, Y., Takeda, T., Narita, F.: Effect of damage on the interlaminar shear properties of hybrid composite laminates at cryogenic temperatures. Compos. Struct. 93, 124–131 (2010)10.1016/j.compstruct.2010.06.008 ↗
11. Rybicki, E.F., Kanninen, M.F.: A finite element calculation of stress intensity factors by a modified crack closure integral. Eng. Fract. Mech. 9, 931–938 (1977)10.1016/0013-7944(77)90013-3 ↗
12. Krueger, R.: Virtual crack closure technique: history, approach, and applications. ASME Appl. Mech. Rev. 57(2), 109–143 (2004)10.1115/1.1595677 ↗
13. Sundararaman, V., Davidson, B.D.: An unsymmetric double cantilever beam test for interfacial fracture toughness determination. Int. J. Solids Struct. 34(7), 799–817 (1997)10.1016/S0020-7683(96)00055-8 ↗
14. Sharif, F., Kortschot, M.T., Martin, R.H.: Mode III delamination using a split cantilever beam. In: Martin, R.H. (ed.) Composite Materials: Fatigue and Fracture, vol. 5, pp. 85–99. ASTM STP 1230, American Society for Testing and Materials, Philadelphia (1995)10.1520/STP14009S ↗
15. Greenhalgh, E.S., Rogers, C., Robinson, P.: Fractographic observations on delamination growth and the subsequent migration through the laminate. Compos. Sci. Technol. 69, 2345–2351 (2009)10.1016/j.compscitech.2009.01.034 ↗
16. Lee, S.M.: Mode II delamination failure mechanisms of polymer matrix composites. J. Mater. Sci. 32, 1287–1295 (1997)10.1023/A:1018552506085 ↗
17. Gregory, J.R., Spearing, S.M.: Constituent and composite quasi-static and fatigue fracture experiments. Compos. Part A Appl. Sci. Manuf. 36, 665–674 (2005)10.1016/j.compositesa.2004.07.007 ↗
18. Nishijima, S., Okada, T., Honda, Y.: Evaluation of epoxy resin by positron annihilation for cryogenic use. Adv. Cryog. Eng. 40, 1137–1144 (1994)