journal article·2020-11-01

Rational Use of High-Strength Concrete in Flat Slab-Column Connections under Seismic Loading

Authors not provided

ACI Structural Journal· Volume 117· Issue 6
Publisher page

Abstract

First Name is required invalid characters Last Name is required invalid characters Email Address is required Invalid Email Address Invalid Email Address
Only a short abstract or summary was supplied by the source.
Source: openalex_inverted_index · Quality: short

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (32)

Show source-provided references
1. Broms, C. E., “Flat Plates in Seismic Areas: Comparison of Shear Reinforcement Systems,” ACI Structural Journal, V. 104, No. 6, Nov.-Dec. 2007, pp. 712-721.10.14359/18953 ↗
2. Lips, S.; Ruiz, M. F.; and Muttoni, A., “Experimental Investigation on Punching Strength and Deformation Capacity of Shear-Reinforced Slabs,” ACI Structural Journal, V. 109, No. 6, Nov.-Dec. 2012, pp. 889-900.10.14359/51684132 ↗
3. Ferreira, M. P.; Melo, G. S.; and Regan, P. E.; Vollum, R. L., “Punching of Reinforced Concrete Flat Slabs with Double-Headed Shear Reinforcement,” ACI Structural Journal, V. 111, No. 2, Mar.-Apr. 2014, pp. 363-374.10.14359/51686535 ↗
4. Isufi, B.; Pinho Ramos, A.; and Lúcio, V., “Reversed Horizontal Cyclic Loading Tests of Flat Slab Specimens with Studs as Shear Reinforcement,” Structural Concrete, V. 20, No. 1, 2019, pp. 330-347. doi: 10.1002/suco.20180012810.1002/suco.201800128 ↗
5. Almeida, A. F. O.; Alcobia, B.; Ornelas, M.; Marreiros, R.; and Ramos, A. P., “Behaviour of Reinforced-Concrete Flat Slabs with Stirrups under Reversed Horizontal Cyclic Loading,” Magazine of Concrete Research, V. 72, No. 7, 2020, pp. 339-356. doi: 10.1680/jmacr.18.0020910.1680/jmacr.18.00209 ↗
6. Almeida, A. F. O.; Ramos, A. P.; Lúcio, V.; and Marreiros, R.,“Behavior of RC Flat Slabs with Shear Bolts under Reversed Horizontal Cyclic Loading,” Structural Concrete, V. 21, No. 2, 2020, pp. 501-516. doi: 10.1002/suco.20190012810.1002/suco.201900128 ↗
7. Marzouk, H., and Hussein, A., “Experimental Investigation on the Behaviour of High-Strength Concrete Slabs,” ACI Structural Journal, Sept.-Oct., 1991, pp. 701-713.
8. Ozden, S.; Ersoy, U.; and Ozturan, T., “Punching Shear Tests of Normal- and High-Strength Concrete Flat Plates,” Canadian Journal of Civil Engineering, V. 33, No. 11, 2006, pp. 1389-1400. doi: 10.1139/l06-08910.1139/l06-089 ↗
9. Inácio, M. M. G.; Almeida, A. F. O.; Faria, D. M. V.; Lúcio, V. J. G.; and Ramos, A. P., “Punching of High Strength Concrete Flat Slabs without Shear Reinforcement,” Engineering Structures, V. 103, 2015, pp. 275-284. doi: 10.1016/j.engstruct.2015.09.01010.1016/j.engstruct.2015.09.010 ↗
10. Emam, M.; Marzouk, H.; and Hilal, M. S., “Seismic Response of Slab-Column Connections Constructed with High-Strength Concrete,” ACI Structural Journal, V. 94, No. 2, Mar.-Apr. 1997, pp. 197-205.10.14359/473 ↗
11. Marzouk, H.; Osman, M.; and Hussein, A., “Cyclic Loading of High-Strength Lightweight Concrete Slabs,” ACI Structural Journal, V. 98, No. 2, Mar.-Apr. 2001, pp. 207-214.10.14359/10189 ↗
12. Smadi, M. M., and Bani Yasin, I. S., “Behavior of High-Strength Fibrous Concrete Slab-Column Connections under Gravity and Lateral Loads,” Construction and Building Materials, V. 22, No. 8, 2008, pp. 1863-1873. doi: 10.1016/j.conbuildmat.2007.04.02310.1016/j.conbuildmat.2007.04.023 ↗
13. Aitcin, P.-C., High Performance Concrete: Modern Concrete Technology 5, CRC Press, Boca Raton, FL, 2004, 624 pp.
14. Inácio, M. M. G.; Lapi, M.; and Pinho Ramos, A., “Punching of Reinforced Concrete Flat Slabs – Rational use of High Strength Concrete,” Engineering Structures, V. 206, 2020, p. 110194 doi: 10.1016/j.engstruct.2020.11019410.1016/j.engstruct.2020.110194 ↗
15. Cheng, M.-Y., and Parra-Montesinos, G. J., “Evaluation of Steel Fiber Reinforcement for Punching Shear Resistance in Slab-Column Connections—Part I: Monotonically Increased Load,” ACI Structural Journal, V. 107, No. 1, Jan.-Feb. 2010, pp. 101-109.10.14359/51663394 ↗
16. Gouveia, N. D.; Faria, D. M. V.; and Ramos, A. P., “Assessment of SFRC Flat Slab Punching Behaviour–Part I: Monotonic Vertical Loading,” Magazine of Concrete Research, V. 71, No. 11, 2019, pp. 587-598. doi: 10.1680/jmacr.17.0034310.1680/jmacr.17.00343 ↗
17. Almeida, A. F. O.; Inácio, M. M. G.; Lúcio, V. J. G.; and Ramos, A. P., “Punching Behaviour of RC Flat Slabs under Reversed Horizontal Cyclic Loading,” Engineering Structures, V. 117, 2016, pp. 204-219. doi: 10.1016/j.engstruct.2016.03.00710.1016/j.engstruct.2016.03.007 ↗
18. Kotsovos, G. M., and Kotsovos, M. D., “Flat Slabs without Shear Reinforcement: Criteria for Punching,” Structural Engineering, V. 87, No. 1, 2009, pp. 2-8.
19. Faria, D. M. V.; Biscaia, H.; Lucio, V. J. G, and Ramos, A. P., “Material and Geometrical Parameters Affecting Punching of Reinforced Concrete Flat Slabs,” fib Symposium 2011 – Concrete Engineering for Excellence and Efficiency. Prague, Czech Republic, 2011.
20. Silva Mamede, N. F.; Pinho Ramos, A.; and Faria, D. M. V., “Experimental and Parametric 3D Nonlinear Finite Element Analysis on Punching of Flat Slabs with Orthogonal Reinforcement,” Engineering Structures, V. 48, 2013, pp. 442-457. doi: 10.1016/j.engstruct.2012.09.03510.1016/j.engstruct.2012.09.035 ↗
21. Duval, R., and Kadri, E. H., “Influence of Silica Fume on the Workability and the Compressive Strength of High-Performance Concretes,” Cement and Concrete Research, V. 28, No. 4, 1998, pp. 533-547. doi: 10.1016/S0008-8846(98)00010-610.1016/S0008-8846(98)00010-6 ↗
22. Igarashi, S. I.; Watanabe, A.; and Kawamura, M., “Evaluation of Capillary Pore Size Characteristics in High-Strength Concrete at Early Ages,” Cement and Concrete Research, V. 35, No. 3, 2005, pp. 513-519. doi: 10.1016/j.cemconres.2004.06.03610.1016/j.cemconres.2004.06.036 ↗
23. Bhanja, S., and Sengupta, B., “Influence of Silica Fume on the Tensile Strength of Concrete,” Cement and Concrete Research, V. 35, No. 4, 2005, pp. 743-747. doi: 10.1016/j.cemconres.2004.05.02410.1016/j.cemconres.2004.05.024 ↗
24. Siddique, R., “Utilization of Silica Fume in Concrete: Review of Hardened Properties,” Resources, Conservation and Recycling, V. 55, No. 11, 2011, pp. 923-932. doi: 10.1016/j.resconrec.2011.06.01210.1016/j.resconrec.2011.06.012 ↗
25. CEN, EN 12390-3, “Testing Hardened Concrete Part 3: Compressive Strength of Test Specimens,” Bruxelles, Belgium, 2001, 15 pp.
26. CEN, EN 12390-6, “Testing hardened Concrete Part 6: Tensile Splitting Strength of Test Specimens,” Bruxelles, Belgium, 2000, 10 pp.
27. CEN, EN 12390-13, “Testing Hardened Concrete Part 13: Determination of Secant Modulus of Elasticity in Compression,” Bruxelles, Belgium, 2013, 16 pp.
28. CEN, EN 10002-1, “Metallic Materials Tensile Testing Part 1: Method of Test at Ambient Temperature,” Bruxelles, Belgium, 2001, 57 pp.
29. Ramos, A.; Marreiros, R.; Almeida, A., Isufi, B.; and Inácio, M., “Punching of Flat Slabs under Reversed Horizontal Cyclic Loading,” In: Ospina, C. E., Mitchell, D., Muttoni, A., eds., SP-315, 2017, pp. 253-272.10.35789/fib.BULL.0081.Ch13 ↗
30. EN 1992-1-1, “Eurocode 2—Design of Concrete Structures. Part 1-1: General Rules and Rules for Buildings,” European Committee for Standardization, Brussels, Belgium, 2004.
31. Hose, Y. D., and Seible, F., “Performance Evaluation Database for Concrete Bridge Components and Systems under Simulated Seismic Loading, PEER Report No. 1999/11,” San Diego, CA, 1999, 114 pp.
32. Gouveia, N. D.; Faria, D. M. V.; and Ramos, A. P., “Assessment of SFRC Flat Slab Punching Behaviour – Part II: Reversed Horizontal Cyclic Loading,” Magazine of Concrete Research, V. 71, No. 1, 2019, pp. 26-42. doi: 10.1680/jmacr.17.0034410.1680/jmacr.17.00344 ↗