journal article·2012-09

Failure Causes of a Polymer Resettable Circuit Protection Device

Shunfeng Cheng, Kwok Tom, Michael Pecht

Journal of Electronic Materials· Volume 41· Issue 9
Publisher page

Abstract

As a circuit protection device, failure or abnormal behavior of polymer positive-temperature-coefficient resettable devices can cause damage to circuits. Identification of failure modes and determination of failure causes are necessary to improve the reliability of resettable circuit protection devices and understand their limitations. In this study, a series of experiments was conducted to identify the failure modes of polymer positive-temperature- coefficient resettable circuit protection devices. The causes of failures of a polymer positive-temperature-coefficient resettable circuit protection device were determined by failure analyses, including analysis of the increase in surface temperature using an infrared camera, interconnection analysis using cross-sectioning and environmental scanning electron microscopy, analysis of the microstructures of carbon-black-filled polymer composite, thermal property analysis of the polymer composite, and coefficient of thermal expansion analysis of different parts of the resettable circuit protection device.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Electrostatic Discharge in Electronics · Electrical Fault Detection and Protection · Safety Systems Engineering in Autonomy

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. S. Cheng, K. Tom, and M. Pecht, IEEE Trans. Device Mater. Reliab. 10, 374 (2010).10.1109/TDMR.2010.2053371 ↗
2. S. Cheng and M. Pecht, Expert Syst. Appl. 39, 8467 (2012).10.1016/j.eswa.2012.01.172 ↗
3. D. Wei, T. Zhao, and X. Yi, J. Appl. Polym. Sci. 77, 53 (2000).10.1002/(SICI)1097-4628(20000705)77:1<53::AID-APP8>3.0.CO;2-8 ↗
4. S. Luo and C. Wong, IEEE Trans. Compon. Packag. Technol. 23, 151 (2000).10.1109/6144.833054 ↗
5. N. Zhen, J. Casanova, P. Maier, J. Taylor, R. Chinga, and J. Lin, IEEE Trans. Ind. Electron. 57, 1478 (2010).10.1109/TIE.2009.2030821 ↗
6. Y. Xiong, X. Cheng, S.Z. Shen, C. Mi, H. Wu, and V. Garg, IEEE Trans. Ind. Electron. 55, 2268 (2008).10.1109/TIE.2008.918399 ↗
7. J. Cao and A. Emadi, IEEE Trans. Ind. Electron Mag. 5, 27 (2011).10.1109/MIE.2011.940251 ↗
8. J. Garate, J. de Diego, and M. Sierra, Proc.32nd IECON (Paris, 2006), p.2187.10.1109/IECON.2006.347733 ↗
9. UL 1434, Standard for Safety for Thermistor-Type Devices (August, 2002).
10. H. He, P. Deng, L. Dong, and J. Sun, J. Appl. Polym. Sci. 85, 2742 (2002).10.1002/app.10720 ↗
11. E. Park, Macromol. Mater. Eng. 291, 690 (2006).10.1002/mame.200500425 ↗
12. S. Huang, J. Lee, and C. Ha, Colloid Polym. Sci. 282, 575 (2004).10.1007/s00396-003-0980-4 ↗
13. X. Xu, Z. Li, R. Yu, A. Lu, M. Yang, and R. Huang, Macromol. Mater. Eng. 289, 568 (2004).10.1002/mame.200400016 ↗
14. H. Yui, G. Wu, H. Sano, M. Sumita, and K. Kino, Polymer 47, 3599 (2006).10.1016/j.polymer.2006.03.064 ↗
15. S. Cheng, M. Azarian, and M. Pecht, Sensors 10, 5774 (2010).10.3390/s100605774 ↗
16. M. Pecht, Prognostics and Health Management of Electronics (New York: Wiley–Interscience, 2008).10.1002/9780470385845 ↗
17. M. Pecht and R. Jaai, Microelectron. Reliab. 50, 317 (2010).10.1016/j.microrel.2010.01.006 ↗
18. F. Doljack, IEEE Trans. Compon. Hybr. CHMT-4, 372 (1981).10.1109/TCHMT.1981.1135838 ↗
19. M. Omastova, S. Podhradska, J. Prokes, I. Janigova, and J. Stejskal, Polym. Degrad. Stabil. 82, 251 (2003).10.1016/S0141-3910(03)00218-0 ↗
20. M. Omastova, J. Prokes, S. Kosina, and D. Hlavata, Macromol. Symp. 170, 241 (2001).10.1002/1521-3900(200106)170:1<241::AID-MASY241>3.0.CO;2-A ↗