Excitation-Current-Dependent Magnetoinductance in Inductive Elements Containing CoFeSiB Ribbons Annealed in Transverse Magnetic Field
Source abstract
Abstract
An important issue for the practical application of magnetic field elements is to select an appropriate operating condition. The effect of excitation parameters on the magnetoinductance effect has been investigated in inductive elements consisting of a magnetically annealed Co67Fe4Si14.5B14.5 amorphous ribbon wound with a single coil loaded with an excitation current (Iac). The influence of the frequency on the magnetoinductance effect is closely related to the amplitude of Iac. With an increase of the amplitude of Iac from 1.0 mA to 4.0 mA, the curve of the maximum magnetoinductance ratio (ηmax) versus frequency changes from a monotonic reduction to show a peak of about 2450% at 32.1 kHz. The local average sensitivity (Sloc) remains almost the same across a wider magnetic field range from 0 A m−1 to 32 A m−1 under an excitation current of 4.0 mA at 2.1 kHz. These results demonstrate that both the magnetic field sensitivity and linear measurement range of such inductive elements closely depend on the parameters of Iac, which is discussed herein from the viewpoint of the magnetization dynamics and definition of inductance.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Magnetic Field Sensors Techniques · Magnetic Properties and Applications · Metallic Glasses and Amorphous Alloys
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (36)
Show source-provided references
1. S.D. Jiang, T. Eggers, O. Thiabgoh, D.W. Xing, W.B. Fang, J.F. Sun, H. Srikanth, and M.H. Phan, J. Electron. Mater. 47, 2667 (2018).10.1007/s11664-018-6097-9 ↗
2. S. Zhi, Z. Feng, L. Guo, C. Lei, and Y. Zhou, Sens. Actuators A Phys. 267, 121 (2017).10.1016/j.sna.2017.09.045 ↗
3. B. Dufay, S. Saez, C. Dolabdjian, A. Yelon, and D. Ménard, IEEE Trans. Magn. 49, 85 (2013).10.1109/TMAG.2012.2219579 ↗
4. D. Estévez, A. He, C. Chang, Q. Man, X. Wang, and R. Li, J. Magn. Magn. Mater. 393, 278 (2015).10.1016/j.jmmm.2015.05.080 ↗
5. O. Thiabgoh, T. Eggers, and M.H. Phan, Sens. Actuators A Phys. 265, 120 (2017).10.1016/j.sna.2017.08.043 ↗
6. J. Devkota, T. Luong, J.S. Liu, H. Shen, F.X. Qin, J.F. Sun, P. Mukherjee, H. Srikanth, and M.H. Phan, J. Appl. Phys. 116, 234504 (2014).10.1063/1.4904411 ↗
7. D. He and M. Shiwa, Sensors 14, 10644 (2014).10.3390/s140610644 ↗
8. H. Zhang, Y. Zhao, S. Yang, and H. Li, Sens. Actuators A Phys. 69, 121 (1998).10.1016/S0924-4247(98)00061-2 ↗
9. G. Yu, X. Bu, C. Xiang, and H. Xu, Sens. Actuators A Phys. 161, 72 (2010).10.1016/j.sna.2010.04.037 ↗
10. H.L. Pan, X. Li, Q. Zhang, Y.P. Su, J.T. Wang, W.H. Xie, and Z.J. Zhao, J. Magn. Magn. Mater. 452, 502 (2018).10.1016/j.jmmm.2017.11.014 ↗
11. Z.M. Wu, K. Huang, S.P. Li, J.Y. Kang, Z.J. Zhao, and X.L. Yang, Sens. Actuators A Phys. 161, 62 (2010).10.1016/j.sna.2010.05.025 ↗
12. Aichi Steel, Product information, electro-magnetic product, MI sensor. https://www.aichi-steel.co.jp/ENGLISH/products/electromagnetic/mi_censor/index.html . Accessed 12 Oct 2018.
13. A.S. Antonov, N.A. Nuznikov, I.T. Iakubov, A.N. Lagarkov, and A.L. Rakhmanov, J. Phys. D Appl. Phys. 34, 752 (2001).10.1088/0022-3727/34/5/314 ↗
14. M. Phan and H. Peng, Prog. Mater. Sci. 53, 323 (2008).10.1016/j.pmatsci.2007.05.003 ↗
15. C. Zhao, L. Pan, X. Li, L. Ma, Q. Liu, and J. Wang, J. Phys. D Appl. Phys. 51, 045005 (2018).10.1088/1361-6463/aaa1af ↗
16. B.S. Zhang, Z. Yuan, H. Zhao, Y. Yang, and D.M. Tang, IEEE Trans. Magn. 52, 2000204 (2016).
17. S. Dobák, J. Füzer, and P. Kollár, J. Alloys Compd. 651, 237 (2015).10.1016/j.jallcom.2015.08.084 ↗
18. G. Paltanea, V. Paltanea, and G. Ionescu, UPB Sci. Bull. Ser. C 73, 195 (2011).
19. I. Betancourt, L.A. Martinez, and R. Valenzuela, J. Appl. Phys. 97, 10M101 (2005).10.1063/1.1847212 ↗
20. J. Füzer, S. Dobák, and P. Kollár, J. Alloys Compd. 628, 335 (2015).10.1016/j.jallcom.2014.12.126 ↗
21. H. Liu, C. Yin, X. Miao, and Z. Han, J. Alloys Compd. 466, 346 (2008).
22. S. Chakraborty, K. Mandal, D. Sakar, V.J. Cremaschi, and J.M. Silveyra, Physica B 406, 2011 (1915).
23. R. Valenzuela, Physica B 299, 280 (2001).10.1016/S0921-4526(01)00479-3 ↗
24. T. Eggers, A. Leary, M. McHenry, J. Marcin, I. Škorvánek, H. Srikanth, and M.H. Phan, J. Alloys Compd. 682, 799 (2016).10.1016/j.jallcom.2016.04.312 ↗
25. O. Thiabgoh, H. Shen, T. Eggers, A. Galati, S. Jiang, J.S. Liu, Z. Li, J.F. Sun, H. Srikanth, and M.H. Phan, J. Sci. Adv. Mater. Dev. 1, 69 (2016).
26. T. Eggers, D.S. Lam, O. Thiabgoh, J. Marcin, P. Švec, N.T. Huong, I. Škorvánek, and M.H. Phan, J. Alloys Compd. 741, 1105 (2018).10.1016/j.jallcom.2018.01.206 ↗
27. H. Kikuchi, S. Kamata, Y. Takahashi, and T. Nakai, IEEE Trans. Magn. 51, 4001204 (2015).
28. T.K. Das, A. Mitra, S.K. Mandal, R.K. Roy, P. Banerji, and A.K. Panda, Sens. Actuators A Phys. 220, 382 (2014).10.1016/j.sna.2014.10.027 ↗
29. R.S. Beach, N. Smith, C.L. Platt, and F. Jeffers, Appl. Phys. Lett. 68, 2753 (1996).10.1063/1.115587 ↗
30. X. Lin, J. Li, and M. Tang, IEEE Trans. Magn. 53, 2001806 (2015).
31. A.K. Mazeeva and P.A. Kuznetsov, Phys. Met. Metall. 117, 857 (2016).10.1134/S0031918X16090052 ↗
32. S. Tumanski, Meas. Sci. Technol. 18, R31 (2007).10.1088/0957-0233/18/3/R01 ↗
33. A.K. Panda, S. Basu, and A. Mitra, J. Magn. Magn. Mater. 261, 190 (2003).10.1016/S0304-8853(02)01472-5 ↗
34. K. Byon, S. Yu, J. Kim, and C. Kim, IEEE Trans. Magn. 36, 3439 (2000).10.1109/20.908853 ↗
35. M. Carara, M.N. Baibich, and R.L. Sommer, J. Appl. Phys. 88, 331 (2000).10.1063/1.373662 ↗
36. K. Mandal, S. Pan Mandal, M. Váquez, and A. Hernando, Phys. Rev. B 65, 064402 (2002).10.1103/PhysRevB.65.064402 ↗