journal article·1986-01

Transport and preconcentration of explosives vapors by liquid sampling modules

D. P. Lucero, E. M. Boncyk

Journal of Energetic Materials· Volume 4· Issue 1-4
Publisher page

Abstract

Abstract For most explosives vapor detection scenarios, the lower detection limit (LDL) requirements are at part-per-trillion (ppt) concentration levels. Further sensitivity constraints are imposed on the detector modules by attendant sampling dilution and inefficient transport of explosives vapor molecules through the detection system sample train. Efficient transport and large preconcentration factors (≃ 100,000) can be achieved simultaneously by using a liquid sampling module, comprising a wetted-wall column in the sample train. Liquid sampling modules are interfaced most effectively to wet-chemical detectors. The transport and preconcentration processor introduces a 60-s or longer lag to the overall system time rate-of-response depending on the preconcentration requirements. Despite the long delay time of liquid preconcentrators and the relatively slow rate-of-response time and limited sensitivity of wet-chemical vapor detectors, it appears that their use is feasible for some applications. For example, those detectors with a liquid transport and preconcentration sample train can monitor the atmosphere within enclosures such as rooms, buildings, etc. The inlet to the sample can be located at some convenient and effective point, e.g., in the main air conditioning or ventilation duct upstream of the blower. An explosives vapor detection system comprising a liquid sampling module and a wet-chemical detector and their ancillary equipment can be an effective device for some applications. Integration of a liquid sampling module into a system can extend the LDL of an enzymatic bioluminescent TNT detection technique to an equivalent 0.001 ppt gas phase concentration. It is accomplished by the extraordinary sample preparation achieved by a liquid sampling module in the form of efficient sample transport and sample concentration. Currently two liquid sampling modules for vapor detection systems are in development by the U.S. Army. Fort Belvoir is developing Spincon: a batch-type sampling module for an explosives detection system employing an enzymatic bioluminescent technique. The Aberdeen Proving Ground is developing BezeTrog: a continuous liquid sampling module for the detection of hazardous waste gas molecules in the flue streams employing a coloriometric technique. A liquid sampling module is used as an end-line device interfacing directly with the detector. It contributes significantly to the detection system's performance in meeting the very stringent requirements imposed on explosives vapor detection systems. Although a liquid sampling module fits easily into the general scheme of a typical vapor detection network its design and implementation is a major engineering undertaking.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Mass Spectrometry Techniques and Applications · Analytical Chemistry and Chromatography · Analytical Chemistry and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (23)

Show source-provided references
1. 10.1520/JTE10789J10.1520/JTE10789J ↗
2. 10.1021/ac50005a05410.1021/ac50005a054 ↗
3. Peterson P. K. · Proceedings, New Concepts Symposium and Workshop on Detection and Identification of Explosives · 1978 · 85
4. Lucero D. P. · Proceedings, New Concepts Symposium and Workshop on Detection and Identification of Explosives · 1978 · 65
5. Pate C. T. · 1975
6. Federal Register · 1975 · 40 · 33
7. Williams W. D. · 1981
8. Buckley, J. A., French, J. B. and Reid, N. M. 1978.Proceedings, New Concepts Symposium and Workshop on Detection and Identification of Explosives, 109NTIS No. PB290055.
9. Wernlund, R. F., Cohen, M. J. and Kindel, R. C. 1978.Proceedings, New Concepts Symposium and Workshop on Detection and Identification of Explosives, 185NTIS No. PB290055.
10. Williams, W. D. and Syverson, J. K. April 1981.Explosives Detector Field Tests, April, 24–34. Washington, DC: Research and Development Division, dureau of Alcohol, Tobacco and Firearms U.S. Deparment of the Treasury.
11. Thomas, P. J., May, J. H., Elisco, D. E. and Conrad, F. J. 1978.Proceeding, New Concepts Symposium and Workshop on Detection and Identification of Explosives, 81NTIS No. PB296055.
12. Conrad F. J. · 1978
13. Cage B. R. · 1985
14. Lucero D. P. · 1986
15. Skelland, A. H.P. 1974.Diffusional Mass Transfer, 266–268. New York: John Wiley & Sons.
16. Lucero D. P. · J. Chromatog. Sci. · 1983 · 23 · 29310.1093/chromsci/23.7.293 ↗
17. Albro T. G. · 1986
18. Senum G. I. · 1979
19. 10.1021/ac50007a01210.1021/ac50007a012 ↗
20. Doali J. O. · J. Chromatag. Sci. · 1974 · 12 · 5110.1093/chromsci/12.1.51 ↗
21. Hobbs, J. Cambridge, MA USA: Transport Systems Center, U.S. Department of Transportation Kendall Square. Personal Communication
22. Vellom, D., Hinkley, J., Loucks, A., Egghart, H. and Deluca, M. 1984.Analytical Applications of Bioluminence and Chemiluminescence, 133The Academic Press, Inc.
23. DeLuca, Dr. Marlene. May 7 1986. May 7, San Diego, CA: University of California. Interview with, Professor of Chemistry