Evaluation of Multiple (3-Cycle) Decontamination Processing for Filtering Facepiece Respirators
Source abstract
Abstract
Disposable N95 filtering facepiece respirators (FFRs) certified by the National Institute for Occupational Safety and Health (NIOSH) are widely used by healthcare workers to reduce exposures to infectious biological aerosols. There is currently major concern among public health officials about a possible shortage of N95 FFRs during an influenza pandemic. Decontamination and reuse of FFRs is a possible strategy for extending FFR supplies in an emergency; however, the NIOSH respirator certification process does not currently include provisions for decontamination and reuse. Recent studies have investigated the laboratory performance (filter aerosol penetration and filter airflow resistance) and physical integrity of FFRs following one-cycle (1X) processing of various decontamination treatments. The studies found that a single application of some methods did not adversely affect laboratory performance. In the event that healthcare facilities experience dramatic shortages of FFR supplies, multiple decontamination processing may become necessary. This study investigates three-cycle (3X) processing of eight different methods: ultraviolet germicidal irradiation, ethylene oxide, hydrogen peroxide gas plasma, hydrogen peroxide vapor, microwave-oven-generated steam, bleach, liquid hydrogen peroxide, and moist heat incubation (pasteurization). A four-hour 3X submersion of FFR in deionized water was performed for comparison (control). Following 3X treatment by each decontamination and control method, FFRs were evaluated for changes in physical appearance, odor, and laboratory filtration performance. Only the hydrogen peroxide gas plasma treatment resulted in mean penetration levels > 5% for four of the six FFR models; FFRs treated by the seven other methods and the control samples had expected levels of filter aerosol penetration (< 5%) and filter airflow resistance. Physical damage varied by treatment method. Further research is still needed before any specific decontamination methods can be recommended.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Infection Control and Ventilation · Infection Control in Healthcare · Burn Injury Management and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
URS Corporation, Pittsburgh, Pennsylvania
National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, Pennsylvania
Applied Research Associates, Tyndall Air Force Base, Florida
Air Force Research Laboratory, Tyndall Air Force Base, Florida
University of Nebraska Medical Center, Omaha, Nebraska
References (28)
Show source-provided references
1. CDC, Centers for Disease Control and Prevention. Interim Recommendations for Facemask and Respirator Use to Reduce 2009 Influenza A (H1N1) Virus Transmission, 2009 (Historical Archive), Available from: http://www.cdc.gov/h1n1flu/masks.htm (accessed October 14, 2010).
2. CDC, Centers for Disease Control and Prevention. Interim Guidance on Infection Control Measures for 2009 H1N1 Influenza in Healthcare Settings, Including Protection of Healthcare Personnel (Historical Archive), Available from: http://www.cdc.gov/h1n1flu/guidelines_infection_control.htm (accessed October 14, 2010).
3. OSHA, Occupational Safety and Health Administration. Pandemic Influenza Preparedness and Response Guidance for Healthcare Workers and Healthcare Employers. U.S. Department of Labor. OSHA pub# 3328–05, 2007, Available from: http://osha.gov/Publications/3328-0–2007-English.html (accessed October 14, 2010).
4. CFR, Code of Federal Regulations. Respiratory Protective Devices, Title 42, Part 84, 1995, 30336–30404.
5. 10.1016/j.ajic.2004.04.19910.1016/j.ajic.2004.04.199 ↗
6. 10.1016/j.ajic.2005.08.01810.1016/j.ajic.2005.08.018 ↗
7. 10.1093/annhyg/men01910.1093/annhyg/men019 ↗
8. 10.1080/1542811989101038910.1080/15428119891010389 ↗
9. 10.1080/1047322X.1997.1038953310.1080/1047322X.1997.10389533 ↗
10. 10.1016/S0003-4878(97)00022-710.1016/S0003-4878(97)00022-7 ↗
11. IOM, Institute of Medicine. · 2006
12. 10.1016/j.ajic.2008.09.02110.1016/j.ajic.2008.09.021 ↗
13. NIOSH, National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory. Respirator Trusted-Source Information Page, 2009, Available from: http://www.cdc.gov/niosh/npptl/topics/respirators/disp_part/RespSource.html (accessed October 14, 2010).
14. Viscusi D.J. · Journal of the International Society for Respiratory Protection · 2007 · 24 · 93
15. Viscusi D.J. · Annals of Occupational Hygiene · 2009 · 53 · 815
16. 10.1128/AEM.01653-0810.1128/AEM.01653-08 ↗
17. 10.1111/j.1364-5072.2010.04881.x10.1111/j.1364-5072.2010.04881.x ↗
18. 10.1128/AEM.00799-0910.1128/AEM.00799-09 ↗
19. Brown R.C. · Annals of Occupational Hygiene · 1998 · 32 · 271
20. 10.1080/1047322005007560810.1080/10473220050075608 ↗
21. 10.1080/1542811989101070310.1080/15428119891010703 ↗
22. Blackford D.B. · Proceedings of the Fourth World Filtration Congress · 1986
23. Kanaoka C. · 1984 · 613
24. Van Turnhout J. · 1975 · 87
25. 10.1080/1047322005007561710.1080/10473220050075617 ↗
26. FDA, Food and Drug Administration. Masks and N95 respirators, 2009, Available from: http://www.fda.gov/MedicalDevices/ProductsandMedicalProcedures/GeneralHospitalDevicesandSupplies/PersonalProtectiveEquipment/ucm055977.htm (accessed October 14, 2010).
27. 10.1016/j.jhin.2009.08.02010.1016/j.jhin.2009.08.020 ↗
28. 10.1093/annhyg/men08610.1093/annhyg/men086 ↗