journal article·2019-01Open access

Research on finger movement sensing performance of conductive gloves

Xiaoxue Han, Xuhong Miao, Xi Chen, Gaoming Jiang, Li Niu

Abstract

Knitted flexible sensors are sensors based on the loop structure of knitted fabric, which are soft and close-fitting. Monitoring finger motion can obtain useful information for some applications such as rehabilitation medicine, sports bionics, or human–computer interaction. In this paper, a conductive glove was knitted by SHIMA Seiki SWG 061N-15G computerized flat knitting machine. One experimenter wore it to measure motions data of index finger. The glove has a conductive intarsia area knitted by silver-nylon filaments. The experimenter performed static and dynamic test of hand posture, respectively, then observed the effect of figure bending characteristics on the glove resistance data. The result showed that human finger motion can be monitored successfully by the conductive glove without hard transducers, and both of the bending rate ( Br) and bending angle of the finger proximal interphalangeal joint ( Pba) affect the resistance change of the conductive area of the glove. In other words, the conductive glove has potentials to monitor and reflect human finger motions in detail.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Tactile and Sensory Interactions · Muscle activation and electromyography studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Engineering Research Center for Knitting Technology, Ministry of Education, Jiangnan University, Wuxi, China

School of Textiles and Clothing, Jiangnan University, Wuxi, China

Funding

National Natural Science Foundation of China

References (21)

Show source-provided references
1. 10.1038/nnano.2011.3610.1038/nnano.2011.36 ↗
2. 10.1021/nn402728g10.1021/nn402728g ↗
3. Glazzard M
4. 10.1080/1542140080190469010.1080/15421400801904690 ↗
5. 10.1021/acsami.5b0069510.1021/acsami.5b00695 ↗
6. 10.1177/004051751452856010.1177/0040517514528560 ↗
7. 10.1177/004051751878627510.1177/0040517518786275 ↗
8. Pacelli M
9. 10.1533/9780857093530.3.42010.1533/9780857093530.3.420 ↗
10. Ren Z · 1093
11. 10.1016/S1672-6529(11)60095-410.1016/S1672-6529(11)60095-4 ↗
12. Perng JK · 178
13. Cai Q · 2011
14. 10.1177/004051751557833310.1177/0040517515578333 ↗
15. Liancang J · Nerve Inj Funct Reconstr · 1991 · 3 · 122
16. Li Y · Comput Eng Appl · 2002 · 38 · 55
17. Wu J · Pattern Recognit Artif Intell · 1999 · 3 · 74
18. Guan D · 2009
19. Han X · J Text Res · 2019 · 40 · 66
20. 10.3390/s13081111410.3390/s130811114 ↗
21. GB/T 18459-2001. Methods for calculating the main static performance specifications of transducers.