Analysis of Misalignment in the Tension Test
Source abstract
Abstract
Many experimenters fail to appreciate the significance of test system alignment during a tensile test. Poor alignment can increase data scatter and significantly influence some of the test results. In this paper a comprehensive analytical study of the misalignment problem in the plastic strain range is presented and errors caused by misalignment estimated. The results show that the stress-strain curve is not significantly affected by misalignment. However, the strains at the outer most fibers of the specimen cross-section are stongly affected by misalignment. Therefore, the effect of misalignment is most important when properties sensitive to local strain concentrations are being investigated.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Non-Destructive Testing Techniques · Fatigue and fracture mechanics · Metal Forming Simulation Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Division of Materials Engineering, University of Iowa, Iowa City, Iowa 52242
Materials Division, NASA - Langley Research Center, Hampton, Va. 23665
References
Reference metadata was not supplied for this record.