Fatigue Behavior of a 22Cr-20Ni-18Co-Fe Alloy at Elevated Temperatures
Source abstract
Abstract
An experimental investigation was conducted on Haynes Alloy 556 to study the fatigue behavior of the material at elevated temperatures. Fatigue tests were run at constant temperatures ranging from room temperature to 871°C with strain ranges from 0.265 to 1.5 percent resulting in lives between 102 and 106 cycles. Cyclic deformation properties were evaluated based on the fatigue data. Three fatigue life models were evaluated for their ability to predict the isothermal fatigue lives of the material. These included the Ostergren, Frequency Separation and Stress-Strain-Time models. Strengths and weaknesses of each model are discussed based on the experimental results.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: High Temperature Alloys and Creep · Fatigue and fracture mechanics · Fire effects on concrete materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Mechanical Engineering Department, The University of Toledo, Toledo, OH 43606
Metals and Ceramics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831
References