journal article·1994-10-01

The Compliance Method for Measurement of Near Surface Residual Stresses—Application and Validation for Surface Treatment by Laser and Shot-Peening

W. Cheng, I. Finnie, M. Gremaud, A. Rosselet, R. D. Streit

Publisher page

Abstract

Residual stresses due to surface treatment are measured using the compliance method. The method makes use of the strains measured on the surface while a cut is extended progressively along a plane of interest. The experimental results for a shot peened specimen show good agreement with those obtained by the X-ray method. This experiment demonstrates that the compliance method is accurate and capable of measuring residual stresses which vary rapidly over a depth of less than 50 μm. Good general agreement with results by the X-ray method is also obtained for a laser treated specimen. Some advantages and disadvantages of the present method relative to hole-drilling, layer removal and X-ray methods are discussed.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Surface Treatment and Residual Stress · Laser Material Processing Techniques · Metal Alloys Wear and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Mechanical Engineering Department, University of California, Berkeley, Berkeley, CA, 94720

Departement des Mate´riaux, Ecole Polytechnique Fe´de´rale de Lausanne, 1015 Lausanne, Switzerland

Mechanical Technology, Sulzer-Innotec, 8401 Winterthur, Switzerland

Lawrence Livermore National Laboratory, Livermore, CA 94550

References

Reference metadata was not supplied for this record.