journal article·2006-10-01

Advanced Composite Panels for Seismic and Vibration Mitigation of Existing Structures

Amjad J. Aref, Woo-Young Jung

Publisher page

Abstract

In this paper, a conceptual design, fabrication, and testing of advanced polymer matrix composite (PMC) infill system are addressed for seismic retrofitting of steel frames. Such a system is designed to have a multi-panel PMC infill system with passive energy mechanism. The basic configuration of this system is composed of two separate components—namely, an inner PMC sandwich panel and outer damping panels. The inner PMC sandwich infill consists of two fiber-reinforced polymer (FRP) laminates with Divincell® H core, and outer damping panels are made of FRP laminate plates and passive energy constrained damping layers—combining polymer honeycomb and 3M viscoelastic solid materials—at the interface between the laminates. The interactions of these two components produce considerable stiffness and enhanced damping properties in the structure following different drift level. Conceptually, the FRP outer damping panels are designed to produce the damping through the cyclic shear straining of the combined interface damping layers. Moreover, as the lateral drift increases, the inner PMC sandwich infill is designed to provide considerable lateral stiffness to resist severe earthquake excitation and avoid excessive relative floor displacements that cause both structural and non-structural damage. As part of this research, analytical and experimental studies were performed to investigate the effectiveness of the proposed multi-infill panel concept. The prefabricated multi-panel PMC infill holds a great promise for enhanced damping performance, simplification of the construction process, and the reduction of time and cost when used for seismic retrofitting applications.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Masonry and Concrete Structural Analysis · Structural Analysis of Composite Materials · Vibration and Dynamic Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Civil, Structural & Environmental Engineering, University at Buffalo-State University of New York, 235 Ketter Hall, Buffalo, NY 14260

Department of Civil Engineering, Kangnung National University, Kangnung, 210-702, Republic of Korea

References (18)

Show source-provided references
1. Klingner, L. F., and Bertero, V. V., 1976, “Infilled Frames in Earthquake-Resistant-Construction,” Report No. EERC 76-32, Earthquake Engrg. Res. Ctr., U.C at Berkeley, CA.
2. Mander, J. B., Nair, B., Wojtkowski, K., and Ma, J., 1993, “An Experimental Study on the Seismic Performance of Brick-Infilled Steel Frames With and Without Retrofit,” Technical Report No. NCEER-93-0001, National Center of Earthquake Engineering Research, State University of New York at Buffalo, NY, 1.1–3.1.
3. Influence of Initial Gaps on Infilled Frame Behavior
4. On the Stiffnesses and Strengths of Infilled Frames
5. A Combined Honeycomb and Solid Viscoelastic Material for Structural Damping Applications10.1016/S0167-6636(02)00210-7 ↗
6. Behavior of Masonry Infill Steel Frames10.1139/l89-129 ↗
7. Damping of Frames With Constrained Viscoelastic Layers10.1061/JSDEAG.0005331 ↗
8. Damping of Frames With Viscoelastic Infill Panels10.1061/JSDEAG.0005711 ↗
9. Jung, W.-Y. , 2003, “Seismic Retrofitting Strategies of Semi-Rigid Steel Frames Using Polymer Matrix Composite (PMC) Materials,” Ph.D. thesis, State University of New York at Buffalo, NY.
10. A Study of the Effects of Various Geometric Parameters on the Failure Strength of Pin-Loaded Woven-Glass-Fiber Reinforced Epoxy Laminate10.1016/S0266-3538(01)00043-4 ↗
11. Soong
12. Direct Displacement-Based Design for Building With Passive Energy Dissipation Systems10.1016/S0141-0296(02)00099-8 ↗
14. Kitane, Y. , 2003, “Development of Hybrid FRP-Concrete Bridge Superstructure System” Ph.D. Dissertation, University at Buffalo-State University of New York, Buffalo, NY.
15. Refined 3D Finite Element Modeling of Partially Restrained Connections Including Slip10.1016/S0143-974X(01)00087-6 ↗
16. Energy-Dissipating Polymer Matrix Composite Infill Wall System for Seismic Retrofitting10.1061/(ASCE)0733-9445(2003)129:4(440) ↗
17. Radhakrishan, R. , 2000, “Coupled Thermomechanical Analysis of Viscoelastic Dampers,” MSc. thesis, State University of New York, Buffalo, NY.
18. Non-linear Analysis of Steel Plane Frames With Semi-Rigid Connections