The Cracking of Ti-6Al-4V Alloys Under Sustained Load in Ambient Air

G. R. Yoder, C. A. Griffis, T. W. Crooker

Publisher page

Abstract

This study reveals that degradation in load-carrying capacity owing to sustained-load cracking (SLC) can occur in alloys of the Ti-6Al-4V family. Each of eight alloys tested with fatigue-precracked specimens in ambient room air exhibited the phenomenon, with degradations ranging from 11 to 35 percent. The degree of susceptibility to SLC was seen to be dependent upon crack orientation in rolled plate materials. The threshold stress-intensity factor below which SLC failures will not occur in these alloys, KIt, appears to represent a more conservative fracture-safe design parameter than the plane-strain fracture toughness KIc, which cannot account for time-delayed failures owing to SLC.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fatigue and fracture mechanics · Hydrogen embrittlement and corrosion behaviors in metals · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Strength of Metals Branch, Metallurgy Division, Naval Research Laboratory, Washington, D. C.