journal article·2024-05Open access

Toward improved thermal exposure classes for structural firefighters

Craig Weinschenk, Holli Knight, John W Regan

Journal of Fire Sciences· Volume 42· Issue 3

Abstract

In the early 1970s, there was an initial effort to quantify the conditions under which firefighters are expected to perform. Harvey Utech led this endeavor by defining three levels of thermal exposure—routine, ordinary, and emergency—which were characterized by combining a range of air temperatures and radiative heat fluxes. In the last half-century, there has been a concerted scientific effort to further understand the conditions to which firefighters are exposed during structural firefighting. Research has been conducted on the resiliency of turnout gear and facepiece lenses, the thermal conditions observed during a structure fire, and the impact of firefighter tactics such as ventilation and suppression. The authors synthesize the results from these research areas to update the original thermal classifications to six categories of exposure—routine, Ordinary I, Ordinary II, Emergency I, Emergency II, and Emergency III—which are more representative of the operating environment and protective equipment thresholds that firefighters should be aware of during firefighting operations and tactical decision-making.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire dynamics and safety research · Fire Detection and Safety Systems · Occupational Health and Performance

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Fire Safety Research Institute, UL Research Institutes, Columbia, MD, USA

Funding

Federal Emergency Management Agency · Department of Homeland Security · Assistance to Firefighters Grant · the Fire Prevention and Safety · Research and Development

References (20)

Show source-provided references
1. Utech H
2. Kerber S · 2010
3. 10.1080/00140139.2017.135507210.1080/00140139.2017.1355072 ↗
4. 10.1016/0379-7112(81)90011-410.1016/0379-7112(81)90011-4 ↗
5. Coletta G · 1976
6. Abbott N, Lannefeld T, Erlandson R, et al. Protection from fire: firefighters’ proximity suits. AATCC Syrup. on coated fabrics update, 1976.
7. 10.54206/102376/IGFM449210.54206/102376/IGFM4492 ↗
8. NFPA 1971 · 2018
9. NFPA 1981 · 2019
10. Mensch A
11. Putorti A
14. NFPA 1981 · 2013
15. Kessler R · J Fire Sci · 2023
16. Kesler R. Evaluation of self-contained breathing apparatus (SCBA) design and weight on firefighter physiological and biomechanical response. Dissertation, University of Illinois at Urbana–Champaign, Champaign, IL, 2022.
17. 10.54206/102376/DNYQ216410.54206/102376/DNYQ2164 ↗
18. 10.54206/102376/DPTN268210.54206/102376/DPTN2682 ↗
19. Weinschenk C · 2022
20. 10.1007/s10694-015-0555-110.1007/s10694-015-0555-1 ↗