journal article·2018-07Open access

Response of stone wool–insulated building barriers under severe heating exposures

Blanca Andres, Karlis Livkiss, Juan P Hidalgo, Patrick van Hees, Luke Bisby, Nils Johansson, Abhishek Bhargava

Journal of Fire Sciences· Volume 36· Issue 4

Abstract

This article presents the experimental results of stone wool–layered sandwich constructions, with either steel or gypsum claddings, tested under four different heating exposures: 7 kW/m 2 incident radiant heat flux exposure, 60 kW/m 2 incident radiant heat flux exposure, parametric time–temperature curve exposure and ISO 834 standard time–temperature exposure. The test apparatus used were a movable radiant panel system, a mid-scale furnace (1.5 m 3 ) and a large-scale furnace (15 m 3 ). The results show that reduced-scale tests are capable of reproducing the heat transferred through the construction at large scale provided there is limited mechanical degradation. The results indicate that the availability of oxygen is fundamental to the fire behaviour of the sandwich composites tested. Reactions occurring in stone wool micro-scale testing, such as oxidative combustion of the binder or crystallisation of the fibres, have a limited effect on the temperature increase when wool is protected from air entrainment.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Wood Treatment and Properties · Fire effects on concrete materials · Fire dynamics and safety research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

The Danish Institute of Fire and Security Technology, Hvidovre, Denmark

Division of Fire Safety Engineering, Lund University, Lund, Sweden

School of Civil Engineering, The University of Queensland, Brisbane, QLD, Australia

School of Engineering, The University of Edinburgh, Edinburgh, UK

Funding

FP7 People: Marie-Curie Actions

References (36)

Show source-provided references
1. International Organization for Standardization (ISO) 834-1:1999. Fire resistance tests – elements of building construction – part 1: general requirements.
2. 10.1002/fam.81610.1002/fam.816 ↗
3. 10.1177/073490411244068810.1177/0734904112440688 ↗
4. 10.3801/IAFSS.FSS.9-130310.3801/IAFSS.FSS.9-1303 ↗
5. 10.1002/(SICI)1099-1018(1998070)22:4<133::AID-FAM642>3.0.CO;2-L10.1002/(SICI)1099-1018(1998070)22:4<133::AID-FAM642>3.0.CO;2-L ↗
6. Sultan M · 495
7. Clancy P · 1999
8. 10.1002/fam.78610.1002/fam.786 ↗
9. 10.1007/s10694-012-0269-610.1007/s10694-012-0269-6 ↗
10. Andres B
11. 10.1002/fam.97110.1002/fam.971 ↗
12. Köning J, Walleij L. Timber frame assemblies exposed to standard and parametric fires: part 2: a design model for standard fire exposure, 1997, https://ri.diva-portal.org/smash/get/diva2:1079798/FULLTEXT01.pdf
13. Andres B
14. 10.1177/073490411876181810.1177/0734904118761818 ↗
15. 10.1007/s10694-016-0625-z10.1007/s10694-016-0625-z ↗
16. Nagy N
17. Sjostrom J
18. 10.1002/fam.90610.1002/fam.906 ↗
19. Bentz DP · 403
20. Olsen H · 1049
21. EN 1993-1-2:2005. Eurocode 3: design of steel structures – part 1–2: general rules – structural fire design.
22. Livkiss K, Andres B, Johansson N, et al. Uncertainties in material thermal modelling of fire resistance tests. In: Proceedings of the 2nd European symposium of fire safety science, Nicosia, Cyprus, 20 June 2015, pp. 1–6. http://fbiw.uniza.sk/kkm/fireff/dokumenty/mozer_30.pdf
23. Hidalgo JP · 2015
24. Dyrbøl S · 1998
25. ISO 1182:2010(en). Reaction to fire tests for products – non-combustibility test.
26. Park S · Fire Mater · 2010 · 34 · 23710.1002/fam.1017 ↗
27. 10.1177/073490411039188910.1177/0734904110391889 ↗
28. 10.1016/j.firesaf.2016.05.001.10.1016/j.firesaf.2016.05.001. ↗
29. Pettersson O, Magnusson SE, Thor J. Fire engineering design of steel structures, 1976, https://lup.lub.lu.se/search/publication/03d5e4a8-6b5d-487b-8af8-db6c90f2502d
30. Incropera FP, DeWitt DP, Bergman TL, et al. Fundamentals of heat and mass transfer. Patent 5,328,671, USA, 2007, 997 pp.
31. EN 1363-1:1999. Fire resistance tests – part 1: general requirements (CEN, 2012).
32. EN 1995-1-2:2004. Eurocode 5: design of timber structures – part 1–2: general-structural fire design.
33. Östman B, Mikkola E, Stein R, et al. Fire safety in timber buildings. SP Trätek, 2010, http://eurocodes.jrc.ec.europa.eu/doc/Fire_Timber_Ch_5-7.pdf
34. Wickström U
35. Aire CT. Experimental and numerical modeling of heat transfer in wall assemblies. Master’s Thesis, University of Saskatchewan, Saskatoon, SK, Canada, 2014.
36. 10.1002/fam.241910.1002/fam.2419 ↗