Improperly grounded electrical equipment can lead to a fire within a home. If electrical equipment in a home is not properly grounded, then an electric fault may cause metal structures (such as heating, ventilation, and air conditioning ducts, metal framing, or screws, nails, and bolts) to become energized without triggering an overcurrent protection device. Electrical connections between these energized materials and grounded objects create an unintended path to ground and can lead to prolonged self-heating that can cause ignition in combustible materials such as wood framing, cellulosic insulation, and other lightweight combustibles. Alternatively, molten metal that is capable of igniting lightweight combustibles can be ejected if the energized surface contacts a well-grounded objected. This article presents results from experiments performed to investigate conditions that cause fires as a result of stray energization of electrically conductive construction items. Resistances, types of nearby combustibles, and other factors were evaluated.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Electrical Fault Detection and Protection · Combustion and Detonation Processes · Risk and Safety Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Exponent, Natick, MA, USA

References (8)

Show source-provided references
1. Hall JR · 2013
2. Smith L, McCoskrie D. Residential electrical distribution system fires. CPSC, 1987, https://www.cpsc.gov/s3fs-public/reselecfire.pdf
3. NBSIR 83-2803:1983. Analysis of electrical fire investigations in ten cities.
4. Smith L · Fire J · 1990 · 84 · 19
5. National Electric Code (NFPA 70). National Fire Protection Association, Article 250.4A, 2008.
6. Trip curve, http://static.schneider-electric.us/docs/Circuit%20Protection/Miniature%20Circuit%20Breakers/QO-QOB%20Circuit%20Breakers/730-3.pdf
7. 10.1109/TIGA.1966.418069610.1109/TIGA.1966.4180696 ↗
8. 10.1520/JFS11733J10.1520/JFS11733J ↗