journal article·2003-07

The Relationship Between Smoke Concentration Some Distance Down the Hallway and the Opening of the Room of Fire Origin

Fang Tingyong, Yang Lizhong, Huang Rui, Feng Wenxing, Zhai Guanglong, Fan Weicheng

Journal of Fire Sciences· Volume 21· Issue 4
Publisher page

Abstract

The smoke concentration at a distant location down a hallway as a function of different openings of the room of fire origin is considered. A series of tests is reported and the smoke sustaining (residence) time, the concentration peak and the concentration buildup rate are investigated as functions of the size of the opening. The smoke sustaining (residence) time, the most important factor concerning smoke toxicity, is described by a novel concept, wavelength, in this study. Furthermore, it is worth emphasizing that the smoke concentration at the sampling point exhibits a phenomenon of vibration in the case of the smallest opening during the test.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire dynamics and safety research · Evacuation and Crowd Dynamics · Fire Detection and Safety Systems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

State Key Laboratory of Fire Science, USTC, Hefei 230026, China

References (13)

Show source-provided references
1. 1. Weicheng, Fan, Qingan, Wang, Fenghui, Jiang and Jianjun, Zhou (1995). Fire Concise Tutorial, Publishing Company of USTC, Hefei, China .
2. 2. Quintiere, James G. (1989). Scaling Applications in Fire Research , Fire Safety Journal, 1: 3-29 .10.1016/0379-7112(89)90045-3 ↗
3. 3. Pauluhn, Jürgen, Kimmerle, Georg, Märtins, Thomas, Prager, Franz and Pump, Wichard (1994). Toxicity of the Combustion Gases from Plastics: Relevance and Limitations of Results Obtained in Animal Experiments , Journal of Fire Sciences, 12:1/2.10.1177/073490419401200104 ↗
4. 4. Kaplan, Harold L., Grand, Arthur, F. and Hartaell, Gordon, E. (1983). Combustion Toxicology Principles and Test Methods. Technomic Publishing Co. Inc., New York, USA .
5. 5. Potts, W.J. and Lederer, T.S. (1997). A Method for Comparative Testing of Smoke Toxicity , Journal of Combustion Toxicology, 4: 114-162 .
6. 6. Robinson, R.S., Dressler, D.P., Dugger, D.L. and Cukor, P. (1997). Smoke Toxicity of Fire-Retardant Television Cabinets , Journal of Combustion Toxicology, 4: 435-435 .
7. 7. Purser, D.A. and Grimshaw, P. (1982). The Incapacitative Effects of Exposure to the Thermal Decomposition Products of Polyurethane Foams, INTERFLAM 82 , Conference Workbook, pp. 71-80 , Univercity of Surrey, Guildford, England.
8. 8. Purser, David. (1982). The Performance of Fire Retardants in Relation to Toxicity, Toxic Hazard, and Risk in Fires. University of Greenwich, London, England .
9. 10.1002/fam.81012020210.1002/fam.810120202 ↗
10. 10.1016/S0379-7112(99)00053-310.1016/S0379-7112(99)00053-3 ↗
11. 10.1016/S0141-3910(97)00225-510.1016/S0141-3910(97)00225-5 ↗
12. 10.1016/S0141-3910(99)00127-510.1016/S0141-3910(99)00127-5 ↗
13. 13. Vandsburger, Uri and Roby, Richard J. (1996). Dynamics, Transport and Chemical Kinetics of Compartment Fire Exhaust Gases, NIST-GCR-96-688.