We present an overview of miniaturized biosensor devices based on the sensitive detection of magnetic nanoparticles using the giant magneto-resistance effect. This detection principle has advantages over established methods, and the sensitivity is promising. In our opinion, the challenge is now in the integration—of sample pretreatment, in a cartridge, of nanoparticles with proper stabilization, magnetic properties, and surface functionalizations.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Magnetic properties of thin films · Characterization and Applications of Magnetic Nanoparticles · Advanced biosensing and bioanalysis techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. Baselt · Biosensors Bioelectr. · 1998 · 13 · 739
2. D. Wild, The Immunoassay Handbook, Nature Publishing Group, 2001.
3. Baibich · Phys. Rev. Lett. · 1988 · 61 · 247210.1103/PhysRevLett.61.2472 ↗
4. Binasch · Phys. Rev. B · 1989 · 39 · 482810.1103/PhysRevB.39.4828 ↗
5. Giant magnetoresistance and magnetic interactions in exchange-biased spin-valves10.1016/S1567-2719(03)15001-9 ↗
6. Lenssen · Sensors Actuators · 2000 · 85 · 110.1016/S0924-4247(00)00342-3 ↗
7. Schotter · IEEE Trans. Magn. · 2002 · 38 · 336510.1109/TMAG.2002.802290 ↗
8. Bethke · Tech. Messen · 2003 · 12 · 57410.1524/teme.70.12.574.20259 ↗
9. Kurlyandskaya · Appl. Phys. Lett. · 2003 · 82 · 305310.1063/1.1571957 ↗
10. Recently, there have also been a few reports on silicon Hall-effect sensors utilizing CMOS, the most widely manufactured semiconductor technology. Traditionally, the noise limits the applicability of CMOS Hall sensors, but recently some progress has been made through architectural and signal processing techniques, see e.g., T. Aytur, P.R. Beatty, B. Moser, et al., Proceedings of the Solid-state Sensor, Actuator and Microsystems Workshop, June 2002, p. 126; P.-A. Besse, G. Boero, M. Derniere, et al., Appl. Phys. Lett. 80 (2002) 4199.
11. Edelstein · Biosensors Bioelectr. · 2000 · 14 · 80510.1016/S0956-5663(99)00054-8 ↗
12. Miller · J. Magn. Magn. Mater. · 2001 · 225 · 13810.1016/S0304-8853(00)01242-7 ↗
13. We have limited ourselves to publications in the peer-reviewed literature; there are probably more groups working on magnetic biosensors, but their progress is difficult to assess.
14. Schotter · Biosensors Bioelectr. · 2004 · 19 · 114910.1016/j.bios.2003.11.007 ↗
15. Rife · Sensors Actuators A · 2003 · 107 · 20910.1016/S0924-4247(03)00380-7 ↗
16. Li · IEEE Trans. Magn. · 2003 · 39 · 331310.1109/TMAG.2003.816760 ↗
17. Li · J. Appl. Phys. · 2003 · 93 · 755710.1063/1.1540176 ↗
18. Sun · J. Appl. Phys. · 1999 · 85 · 432510.1063/1.370357 ↗
19. Sun · J. Am. Chem. Soc. · 2004 · 126 · 27310.1021/ja0380852 ↗
20. Graham · J. Appl. Phys. · 2002 · 91 · 778610.1063/1.1451898 ↗
21. Graham · Biosensors Bioelectr. · 2003 · 18 · 48310.1016/S0956-5663(02)00205-1 ↗
22. Perrin · J. Immunol. Meth. · 1999 · 224 · 7710.1016/S0022-1759(99)00011-3 ↗
23. Rida · Appl. Phys. Lett. · 2003 · 83 · 239610.1063/1.1613038 ↗
24. Lee · Appl. Phys. Lett. · 2001 · 79 · 330810.1063/1.1419049 ↗
25. Wirix-Speetjens · IEEE Trans. Magn. · 2004 · 40 · 194410.1109/TMAG.2004.828930 ↗
26. Lagae · J. Appl. Phys. · 2002 · 91 · 744510.1063/1.1447288 ↗
27. Ferreira · J. Appl. Phys. · 2003 · 93 · 728110.1063/1.1544449 ↗
28. Tamanaha · J. Micromech. Microeng. · 2002 · 12 · N710.1088/0960-1317/12/2/401 ↗