journal article·2017-09Open access

Numerical simulation of magnetic nano drug targeting in a patient-specific coeliac trunk

Andrea Boghi, Flavia Russo, Fabio Gori

Abstract

Abstract Magnetic nano drug targeting, through the use of an external magnetic field, is a new technique for the treatment of several diseases, which can potentially avoid the dispersion of drugs in undesired locations of the body. Nevertheless, due to the limitations on the intensity of the magnetic field applied, the hydrodynamic forces can reduce the effectiveness of the procedure. This technique is studied in this paper with the Computational Fluid Dynamics (CFD), focusing on the influence of the magnetic probe position, and the direction of the circulating electric current. A single rectangular coil is used to generate the external magnetic field. A patient-specific geometry of the coeliac trunk is reconstructed from DICOM images, with the use of VMTK. A new solver, coupling the Lagrangian dynamics of the nanoparticles with the Eulerian dynamics of the blood, is implemented in OpenFOAM to perform the simulations. The resistive pressure, the Womersley’s profile for the inlet velocity and the magnetic field of a rectangular coil are implemented in the software as boundary conditions. The results show the influence of the position of the probe, as well as the limitations associated with the rectangular coil configuration.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Microfluidic and Bio-sensing Technologies · Electrohydrodynamics and Fluid Dynamics · Characterization and Applications of Magnetic Nanoparticles

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (54)

Show source-provided references
1. I.A. for Research on Cancer, W.H. Organization, et al., GLOBOCAN: Estimated Cancer Incidence, Mortality, and Prevalence Worldwide in 2012, IARC, 2014.
2. Hartmann · 1937
3. The flow of conducting fluids in circular pipes under transverse magnetic fields10.1017/S0022112056000421 ↗
4. Magnetohydrodynamic pipe flow Part 2. High hartmann number10.1017/S0022112062000890 ↗
5. Magnetohydrodynamic pipe flow. Part 110.1017/S0022112062000889 ↗
6. Biological effects of electromagnetic fields10.1002/jcb.2400510405 ↗
7. A mathematical model for blood flow in magnetic field10.1063/1.1978807 ↗
8. Application of magnetic techniques in the field of drug discovery and biomedicine10.1186/1477-044X-1-2 ↗
9. Unsteady response of non-newtonian blood flow through a stenosed artery in magnetic field10.1016/j.cam.2008.11.010 ↗
10. Three-dimensional numerical simulation of the fluid dynamics in a coronary stent
11. Image-based computational fluid dynamics in a carotid artery
12. Three-dimensional numerical simulation of the fluid dynamics in a coronary stent
13. Three-dimensional numerical simulation of blood flow in two coronary stents10.1080/10407782.2011.541147 ↗
14. Numerical simulation of blood flow through different stents in stenosed and non-stenosed vessels10.1080/10407782.2014.977151 ↗
15. I. Di Venuta, A. Boghi, F. Gori, Three-dimensional numerical simulation of a failed coronary stent implant at different degrees of residual stenosis. Part i: fluid dynamics and shear stress on the vascular wall, Numer. Heat Transfer, Part A: Appl. (2017, in press).10.1080/10407782.2017.1293985 ↗
16. A. Boghi, I. Di Venuta, F. Gori, Three-dimensional numerical simulation of a failed coronary stent implant at different degrees of residual stenosis. Part ii: apparent viscosity and wall permeability, Numer. Heat Transfer, Part A: App. (2017, in press).10.1080/10407782.2017.1293976 ↗
17. Cfd study on the magnetic fluid delivering in the vessel in high-gradient magnetic field10.1016/j.jmmm.2008.01.041 ↗
18. Measurement of aortic blood flow by doppler echocardiography: day to day variability in normal subjects and applicability in clinical research10.1016/S0735-1097(10)80143-3 ↗
19. Magnetic resonance image processing and structured grid generation of a human abdominal bifurcation10.1016/S0169-2607(98)00008-X ↗
20. Computational simulations of magnetic particle capture in arterial flows10.1007/s10439-009-9786-y ↗
21. Delivery of molecular and cellular medicine to solid tumors10.1016/S0169-409X(00)00131-9 ↗
22. Numerical study of magnetic nanoparticles concentration in biofluid (blood) under influence of high gradient magnetic field10.1016/j.jmmm.2010.08.023 ↗
23. Clinical applications of magnetic drug targeting10.1006/jsre.2000.6030 ↗
24. Clinical experiences with magnetic drug targeting: a phase i study with 4-epidoxorubicin in 14 patients with advanced solid tumors
25. The behaviors of ferromagnetic nano-particles in and around blood vessels under applied magnetic fields10.1016/j.jmmm.2010.09.008 ↗
26. Simulations of magnetic capturing of drug carriers in the brain vascular system10.1016/j.ijheatfluidflow.2012.03.008 ↗
27. Numerical simulation of magnetic nanoparticles targeting in a bifurcation vessel10.1016/j.jmmm.2014.03.002 ↗
28. A novel scheme for nanoparticle steering in blood vessels using a functionalized magnetic field10.1109/TBME.2014.2351234 ↗
29. Numerical simulation of magnetic drug targeting with eulerian-lagrangian model and effect of viscosity modification due to diabetics10.1007/s10483-016-2145-8 ↗
30. Magnetic nanoparticles and blood flow behavior in non-newtonian pulsating flow within the carotid artery in drug delivery application10.1177/0954411916656663 ↗
31. Image-based computational fluid dynamics modeling in realistic arterial geometries10.1114/1.1467679 ↗
32. Magnetically induced electric fields and currents in the circulatory system10.1016/j.pbiomolbio.2004.08.003 ↗
33. On predicting particle-laden turbulent flows10.1007/BF00936835 ↗
34. Biomagnetic uid ow in a 3d rectangular duct10.1002/fld.618 ↗
35. Magnetic nanoparticles for drug delivery10.1016/S1748-0132(07)70084-1 ↗
36. Dispersibility improvement of gold/iron-oxide composite nanoparticles by polyethylenimine modification10.1016/j.jmmm.2009.02.050 ↗
37. A drag coefficient correlation
38. Finite element modeling of three-dimensional pulsatile flow in the abdominal aorta: relevance to atherosclerosis10.1114/1.140 ↗
39. Outflow boundary conditions for arterial networks with multiple outlets10.1007/s10439-008-9527-7 ↗
40. Measurement of blood flow by ultrasound: accuracy and sources of error10.1016/0301-5629(85)90035-3 ↗
41. Abdominal aortic hemodynamics in young healthy adults at rest and during lower limb exercise: quantification using image-based computer modeling10.1152/ajpheart.01301.2005 ↗
42. Numerical simulation of the blood flow in the human cardiovascular system10.1016/0021-9290(95)00027-5 ↗
43. A semi-analytical method for the design of coil-systems for homogeneous magnetostatic field generation10.2528/PIERB11102606 ↗
44. Performance of external and internal coil configurations for prostate investigations at 7 t10.1002/mrm.22552 ↗
45. Magnetic field generating inductor for cancer hyperthermia research10.1108/03321641111152784 ↗
46. Magnetic-particle-sensing based diagnostic protocols and applications10.3390/s150612983 ↗
47. Equations for the magnetic field produced by one or more rectangular loops of wire10.6028/jres.105.045 ↗
48. Hepatocellular carcinoma: regional therapy with a magnetic targeted carrier bound to doxorubicin in a dual mr imaging/conventional angiography suiteinitial experience with four patients 110.1148/radiol.2301021493 ↗
49. Russo · 2015
50. 519/ec of 12 july 1999 on the limitation of exposure of the general public to electromagnetic fields (0 hz to 300 ghz)
51. R.F. Cleveland, D.M. Sylvar, J.L. Ulcek, Evaluating compliance with FCC guidelines for human exposure to radiofrequency electromagnetic fields, Standards Development Branch, Allocations and Standards Division, Office of Engineering and Technology, Federal Communications Commission, 1997.
52. Arterial uptake of biodegradable nanoparticles for intravascular local drug delivery: results with an acute dog model10.1016/S0168-3659(98)00016-9 ↗
53. Arterial uptake of biodegradable nanoparticles: effect of surface modifications10.1021/js980021f ↗
54. Characterization of nanoparticle uptake by endothelial cells10.1016/S0378-5173(01)00923-1 ↗