The influence of bias magnetization of nanoparticles on GMR sensor signal and sensitivity for the ultra-low concentration detection
Source abstract
Abstract
Abstract In the broad research of the GMR bio-sensing technology, it is vital to explore appropriate magnetic labels and its influences on the detection signal. In this work, four kinds of ferrite particles of γ-Fe2O3, CoFe2O4, NiFe2O4 and NiZnFe2O4 were prepared through calcining the Dimethyl Formamide (DMF) solution of the transition metal nitrates [Fe(NO3)3 and X(NO3)2, X = Co, Ni, Zn] to study the effect of magnetic properties on detection signals using a DC in-plane measuring method. It was revealed that for four particles, the output voltage differences |ΔV| between with and without magnetic particles exhibit log-linear functions of the particles concentrations x in the range from 0.1 to 10 ng/mL. A very low limitation of detection (LOD) of 0.1 ng/mL for all the samples was obtained, which is two orders smaller than that in the previous work. Moreover, the change of output voltage difference at the LOD (|ΔVlim|) is proportional to the magnetization at bias field (bias magnetization, Mbias), which indicates that larger Mbias leads to a lower LOD. This work provides a useful guidance in selecting or preparing magnetic labels to enhance the sensitivity of GMR biosensors.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Characterization and Applications of Magnetic Nanoparticles · Magnetic properties of thin films · Iron oxide chemistry and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. Xu · Chin. Phys. B · 2017 · 26 · 01070110.1088/1674-1056/26/1/010701 ↗
2. Rife · Sens. Actuators A: Phys. · 2003 · 107 · 20910.1016/S0924-4247(03)00380-7 ↗
3. Parkin · Proc. IEEE · 2003 · 91 · 66110.1109/JPROC.2003.811807 ↗
4. Baselt · Biosens. Bioelectron. · 1998 · 13 · 73110.1016/S0956-5663(98)00037-2 ↗
5. Gaster · Nat. Nanotechnol. · 2011 · 6 · 31410.1038/nnano.2011.45 ↗
6. Hall · Biosens. Bioelectron. · 2010 · 25 · 205110.1016/j.bios.2010.01.038 ↗
7. Xu · IEEE. Trans. Magn. · 2016 · 52 · 1
8. Xu · J. Magn. Magn. Mater. · 2016 · 417 · 2510.1016/j.jmmm.2016.05.059 ↗
9. Osterfeld · Proc. Natl. Acad. Sci. U.S.A. · 2008 · 105 · 2063710.1073/pnas.0810822105 ↗
10. Graham · J. Appl. Phys. · 2002 · 91 · 778610.1063/1.1451898 ↗
11. Schotter · Biosens. Bioelectron. · 2004 · 19 · 114910.1016/j.bios.2003.11.007 ↗
12. Wang · IEEE. Trans. Magn. · 2008 · 44 · 168710.1109/TMAG.2008.920962 ↗
13. Liang · Biosens. Bioelectron. · 2008 · 24 · 9910.1016/j.bios.2008.03.030 ↗
14. de Boer · Biosens. Bioelectron. · 2007 · 22 · 236610.1016/j.bios.2006.09.020 ↗
15. Llandro · Med. Biol. Eng. Comput. · 2010 · 48 · 97710.1007/s11517-010-0649-3 ↗
16. Srinivasan · Angew. Chem. · 2009 · 48 · 276410.1002/anie.200806266 ↗
17. Berry · J. Phys. D: Appl. Phys. · 2009 · 42 · 22400310.1088/0022-3727/42/22/224003 ↗
18. Govindaiah · J. Colloid Interface Sci. · 2012 · 379 · 2710.1016/j.jcis.2012.04.055 ↗
19. Meyer · J. Microbiol. Methods · 2007 · 68 · 21810.1016/j.mimet.2006.08.004 ↗
20. Li · J. Appl. Phys. · 2004 · 95 · 742010.1063/1.1688218 ↗
21. Zhang · Nanoscale · 2013 · 5 · 766410.1039/c3nr01616a ↗
22. Wang · Sci. Rep. · 2014 · 4 · 571610.1038/srep05716 ↗
23. Sodipo · J. Magn. Magn. Mater. · 2016 · 47 · 27510.1016/j.jmmm.2016.05.019 ↗
24. Kopanja · Ceram. Int. · 2016 · 42 · 1097610.1016/j.ceramint.2016.03.235 ↗
25. Cao · RSC Adv. · 2016 · 6
26. Bao · J. Am. Chem. Soc. · 2007 · 129 · 1237410.1021/ja074458d ↗
27. Lee · Adv. Funct. Mater. · 2010 · 15 · 50310.1002/adfm.200400187 ↗
28. Li · IEEE Trans. Magn. · 2013 · 49 · 405610.1109/TMAG.2013.2237889 ↗
29. Lee · Sci. Rep. · 2016 · 6 · 1869210.1038/srep18692 ↗
30. Ng · Biosens. Bioelectron. · 2016 · 80 · 35910.1016/j.bios.2016.02.002 ↗