Capacitive short circuit detection in transformer core laminations
Source abstract
Abstract
Abstract A capacitive measurement procedure is proposed that serves to detect burr-induced short circuits in transformer core laminations. The tests are conducted on stacks of transformer steel sheets as used for transformer core production and yield a short-circuit probability indicative of the additional eddy current losses to be expected. Applied during the assembly of transformer cores, the measurements can help to decide whether the burr treatment process is working efficiently or has to be readjusted.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Magnetic Properties and Applications · Non-Destructive Testing Techniques · Power Transformer Diagnostics and Insulation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (7)
Show source-provided references
1. IEC International Standard 404-11: Method of a Test for the Determination of Surface Insulation Resistance of Magnetic Sheet and Strip, IEC, 1991.
2. P. Beckley, Electrical Steels, European Electrical Steels, Newport, UK, 2000.
3. British Standard BS 6404 Part 11, 1991: Method of Test for the Determination of the Surface Insulation Resistance of Magnetic Sheet and Strip.
4. Beckley · IEE Proc. Electr. Pow. Appl. · 1998 · 145 · 40910.1049/ip-epa:19982165 ↗
5. Moses · Phys. Scr. · 1989 · 39 · 39110.1088/0031-8949/39/3/025 ↗
6. M.B. Aimoniotis, A.J. Moses, Evaluation of induced eddy currents in transformer sheets due to edge-burrs, in: IEEE/NTUA Athens Power Tech Conference, 1993, pp. 847.10.1109/APT.1993.673914 ↗
7. Mechler · IEEE Trans. Pow. Del. · 2000 · 15 · 19810.1109/61.847251 ↗