journal article·2021-06

A performance improved ACFM-TMR detection system with tradeoff denoising algorithm

Lingsi Sun, Shuxiang Zhao, Ying Shen, Jiazeng Wang, Junqi Gao

Publisher page

Abstract

Abstract This paper presents a novel alternating current field measurement (ACFM) system, which is realized by tunneling magnetoresistive (TMR) sensors and a tradeoff (TO) wavelet denoising algorithm. The TMR sensor is characterized with a high sensitivity of 30 mV/V/Oe and a self-noise of less than 9pT/√Hz at driving frequency f = 3 kHz. TO algorithm is proposed to select the optimum combination of mother wavelet family and decomposition level. The combinations of wavelet Db5 with decomposition level 8 and Sym7 with decomposition level 8 are determined as the most suitable ones for x- and z-axis signal denoising respectively, which have been demonstrated to be better than the traditional low-pass filtering method. Finally, the efficiency of the proposed system is proved by an experiment under more pressing test conditions, for example, with increased lift-off distance of 10 mm. In particular, it leads to increased SNR (signal-to-noise ratio) by 25.5 dB and 16.5 dB for x- and z-axis ACFM signal, respectively.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Non-Destructive Testing Techniques · Magnetic Properties and Applications · Magneto-Optical Properties and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. Analysis of the inducing frequency of a U-shaped ACFM system10.1016/j.ndteint.2010.10.009 ↗
2. High-speed inspection of rails using ACFM techniques10.1016/j.ndteint.2008.12.008 ↗
3. Measurement and modelling of ACFM response to multiple RCF cracks in rail and wheels10.1179/1743281212Y.0000000041 ↗
4. Analysis of the lift-off effect of a U-shaped ACFM system10.1016/j.ndteint.2012.10.001 ↗
5. G.L. Nicholson, A.G. Kostryzhev, X.J. Hao, C.L. Davis, Modelling and experimental measurements of idealised and light-moderate RCF cracks in rails using an ACFM sensor, Ndt E Int., 44 427-437.10.1016/j.ndteint.2011.04.003 ↗
6. Determination of Crack Depth Profile in Cylindrical Metallic Structures, Using Alternating Current Field Measurement Data10.1007/s10921-019-0596-3 ↗
7. A Fuzzy Learning Approach for Identification of Arbitrary Crack Profiles Using ACFM Technique10.1109/TMAG.2013.2254718 ↗
8. Characterisation of clustered cracks using an ACFM sensor and application of an artificial neural network10.1016/j.ndteint.2018.04.007 ↗
9. Uniaxial ACFM Detection System for Metal Crack Size Estimation Using Magnetic Signature Waveform Analysis
10. Le · 2014
11. Experimental and simulation methods to study the Magnetic Tomography Method (MTM) for pipe defect detection10.1016/j.ndteint.2017.07.018 ↗
12. Novel Rotating Current Probe With GMR Array Sensors for Steam Generate Tube Inspection10.1109/JSEN.2016.2556221 ↗
13. Magnetic sensors assessment in velocity induced eddy current testing10.1016/j.sna.2015.02.004 ↗
14. Bobbin Coil Probe With Sensor Arrays for Imaging and Evaluation of LongitudinalCracks Inside Aluminum Tubes10.1109/JSEN.2018.2842090 ↗
15. Investigation of optimal time-domain feature for non-surface defect detection through a pulsed alternating current field measurement technique10.1088/1361-6501/aa9134 ↗
16. Inner circumferential current field testing system with TMR sensor arrays for inner-wall cracks inspection in aluminum tubes10.1016/j.measurement.2018.03.035 ↗
17. A novel TMR-based MFL sensor for steel wire rope inspection using the orthogonal test method10.1088/0964-1726/24/7/075007 ↗
18. A novel sensor to measure the biased pulse magnetic response in steel stay cable for the detection of surface and internal flaws10.1016/j.sna.2017.11.005 ↗
19. Effect of electrode composition on the tunnel magnetoresistance of pseudo-spin-valve magnetic tunnel junction with a MgO tunnel barrier10.1063/1.2742576 ↗
20. Tunnel magnetoresistance of 604% at 300K by suppression of Ta diffusion in CoFeB∕MgO∕CoFeB pseudo-spin-valves annealed at high temperature10.1063/1.2976435 ↗
21. Effect of high annealing temperature on giant tunnel magnetoresistance ratio of CoFeB∕MgO∕CoFeB magnetic tunnel junctions10.1063/1.2402904 ↗
22. A Fuzzy Error Characterization Approach for Crack Depth Profile Estimation in Metallic Structures Through ACFM Data10.1109/TMAG.2017.2701314 ↗
23. Arbitrary Crack Depth Profiling Through ACFM Data Using Type-2 Fuzzy Logic and PSO Algorithm10.1109/TMAG.2018.2884828 ↗
24. Real-time pre-processing of the pulsed eddy current signal from continuous casting slabs10.1784/insi.2012.55.3.136 ↗
25. Wavelet Transform-Based Denoising Method for Processing Eddy Current Signals10.1080/09349847.2010.488799 ↗
26. Improved Wavelet Threshold for Image De-noising
27. Advanced signal processing of magnetic flux leakage data obtained from seamless gas pipeline10.1016/S0963-8695(02)00024-5 ↗
28. Z.H. Du, S.H. Liu, L. Wang, Selection of the optimal wavelet bases for wavelet de-noising of partial discharge signal, International Conference on Signal Processing System, 2010.
29. C.F. Cunha, A. Carvalho, M.R. Petraglia, A.C.S. Lima, An improved scale dependent wavelet selection for data denoising of partial discharge measurement, 2013.
30. Xin'an, Yuan, Wei, Li, Xiaokang, Yin, Guoming, Chen, Jiuhao, Ge, In-service detection of longitudinal cracks on drill pipes using induced circumferential current.
31. Best wavelet basis for wavelet transforms in acoustic emission signals of concrete damage process10.1134/S1061830916030104 ↗
32. Fundamentals of Statistical Signal Processing
33. A new performance evaluation scheme for jet engine vibration signal denoising10.1016/j.ymssp.2016.01.019 ↗
34. Two-Step Interpolation Algorithm for Measurement of Longitudinal Cracks on Pipe Strings Using Circumferential Current Field Testing System10.1109/TII.2017.2728804 ↗
35. Zhou · 2015
36. Z. Wenpei, L. Zhang, Y. Su, T. Fang, Numerical simulation of a U-Shaped ACFM inducer, 2015.
37. A feed-through ACFM probe with sensor array for pipe string cracks inspection10.1016/j.ndteint.2014.06.006 ↗
38. Estimation of Damage Thickness in Fiber-Reinforced Composites using Pulsed Thermography10.1109/TII.2018.2878758 ↗
39. Dynamic Scanning Electromagnetic Infrared Thermographic Analysis Based on Blind Source Separation for Industrial Metallic Damage Evaluation10.1109/TII.2018.2822293 ↗