Numerical Analysis of the Energy Consumption of Ventilation and Dehumidification Processes in the Ice Rink Arena
Source abstract
Abstract
The reduction in energy use in buildings remains a major challenge. In the European Union, buildings account for approximately 40% of the total energy consumption, with sports facilities alone responsible for around 10% of annual use. These facilities are characterised by specific indoor environmental requirements, and ice rink arenas, in particular, represent substantial energy consumers due to the demands of ventilation and dehumidification processes. This paper investigates strategies for maintaining adequate air parameters in an ice rink arena, based on an experimentally verified numerical model of the facility. The research focused on: (1) assessing the energy consumption of different ventilation and air distribution system configurations, and (2) evaluating potential reductions achievable through the implementation of recirculation, heat recovery, and various air handling unit (AHU) configurations, while ensuring appropriate thermal and humidity conditions within the arena. Multi-variant simulations of AHU energy consumption were performed in IDA ICE 4.8 software for both day and night operation over the entire ice rink season. The results showed that the choice and operation of AHU configurations significantly influenced energy consumption as well as the thermal–humidity conditions of the facility, with annual savings of up to 67%.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Infection Control and Ventilation · Building Energy and Comfort Optimization · Indoor Air Quality and Microbial Exposure
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Heating, Ventilation and Dust Removal Technology, Faculty of Energy and Environmental Engineering, Silesian University of Technology, 20 Konarskiego St., 44-100 Gliwice, Poland
Funding
Department of Heating, Ventilation and Dust Removal Technology, Silesian University of Technology
References (27)
Show source-provided references
1. Stankiewicz, M., and Ludwig, R. (2023). Winter Sports Facilities in Poland: Inventory of Sports Infrastructure.
2. Eurohockey.com (2025, September 23). European Ice Hockey Online. Available online: https://www.eurohockey.com/.
3. Statista (2025, September 23). Statista—The Statistics Portal. Available online: https://www.statista.com/.
4. International Ice Hockey Federation (2024). IIHF Official Ice Arena Guide 2024, International Ice Hockey Federation (IIHF).
5. Principles and Methods of Ventilation with Air Dehumidification in Ice Rink Halls
6. Sormunen, P., Sundman, T.L., and Lestinen, S. (2007, January 10–14). The Design Challenges of Multipurpose Arenas. Proceedings of the Clima Well Being Indoors, Helsinki, Finland.
7. Numerical Study of Air Distribution in Indoor Ice Rink Arena
8. Desert Aire (2007). Indoors Ice Rink Dehumidification, Desert Aire. Application Note 13/2007 Rev. 10.
9. ASHRAE (2007). Standard 62: Ventilation for Acceptable Indoor Air Quality, ASHRAE.
10. (2000). Ventilation in Collective Residential and Public Buildings: Requirements (Standard No. PN-83/B-03430:Az3:2000).
11. Taebnia, M., Toomla, S., Leppä, L., and Kurnitski, J. (2019). Air Distribution and Air Handling Unit Configuration Effects on Energy Performance in an Air-Heated Ice Rink Arena. Energies, 12.10.3390/en12040693 ↗
12. Experimental study and numerical prediction of thermal and humidity conditions in the ventilated ice rink arena10.1016/j.buildenv.2016.08.024 ↗
13. Research on improving thermal and humidity conditions in a ventilated ice rink arena using a validated CFD model10.1016/j.ijrefrig.2017.11.016 ↗
14. On-site measurement and numerical investigation of thermal environment with different air distribution systems in ice arenas10.1088/1742-6596/2069/1/012096 ↗
15. Experimental investigation of air distribution and ventilation efficiency in an ice rink arena
16. Indoor thermal and humid stratification and statistical distribution in ice arenas10.1016/j.jobe.2023.106072 ↗
17. A Study on Thermal Characteristics Affected by Air Distribution System Installed in Indoor Ice Rink Arena10.1142/S201013251950007X ↗
18. On-site Measurement of Thermal Environment and Heat Transfer Analysis in a Curling Arena10.1016/j.jobe.2020.101691 ↗
19. Investigation of Displacement and Jet Ventilation Systems Applied in an Ice Rink10.1016/j.jobe.2022.104179 ↗
20. Entransy Analysis and Performance Optimization of the Heat and Humidity Removal Process in Artificial Ice Rinks10.1016/j.jobe.2024.108896 ↗
21. Field Investigation on the Thermal Environmental Construction Challenges of Artificial Ice Rinks: Zonal Mixing and Inter-System Counteraction10.1016/j.enbuild.2025.115324 ↗
22. (2008). Measurement of Fluid Flow in Closed Conduits—Velocity-Area Methods of Flow Measurement in Swirling or Asymmetric Flow Conditions in Circular Ducts by Means of Current-Meters or Pitot Static Tubes (Standard No. ISO 7194).
23. Ministry of Development and Technology (2022). Regulation of the Minister of Development and Technology of 12 April 2002 on the Technical Conditions to Be Met by Buildings and Their Location, Dz.U. 2022, item 1225.
24. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (2011). ASHRAE Handbook, ASHRAE.
25. Ministry of Development and Technology (2023). Regulation of 28 March 2023 Amending the Regulation on the Methodology for Determining the Energy Performance of a Building or Part of a Building and Energy Performance Certificates, Dz.U. 2023, item 697.
26. (2025, November 01). Average Heat Consumption by Customers According to Tariff Groups and Energy Efficiency. Available online: https://pec.gliwice.pl/informacja-o-srednim-zuzyciu-ciepla-przez-odbiorcow-wg-grup-taryfowych-i-efektywnosci-energetycznej/.
27. Moisture handling mechanisms in ice rinks10.1051/e3sconf/202017210010 ↗