journal article·2020-08-29Open access

An Overview of Progressive Collapse Behavior of Steel Beam-to-Column Connections

Iman Faridmehr, Mohammad Hajmohammadian Baghban

Applied Sciences· Volume 10· Issue 17

Abstract

Local failure of one or more components due to abnormal loading can induce the progressive collapse of a building structure. In this study, by the aid of available full-scale test results on double-span systems subjected to the middle column loss scenario, an extensive parametric study was performed to investigate the effects of different design parameters on progressive collapse performance of beam-to-column connections, i.e., beam span-to-depth ratio, catenary mechanism, and connection robustness. The selected full-scale double-span assemblies consisted of fully rigid (welded flange-welded web, SidePlate), semi-rigid (flush end-plate, extended end-plate), and flexible connections (top and seat angle, web cleat). The test results, including load-deformation responses, development of the catenary mechanism, and connection robustness, are presented in detail. The finding of this research further enables a comprehensive comparison between different types of steel beam-to-column connections since the effects of span-to-depth ratio and beam sections were filtered out.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Structural Response to Dynamic Loads · High-Velocity Impact and Material Behavior · Fire effects on concrete materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

South Ural State University, Lenin Prospect 76, Russian Federation, 454080 Chelyabinsk, Russia

Department of Manufacturing and Civil Engineering, Norwegian University of Science and Technology (NTNU), 2815 Gjovik, Norway

References (49)

Show source-provided references
1. Pantidis, P., Cao, L., and Gerasimidis, S. (2020). Partial Damage Distribution and Progressive Collapse of Buildings. Structures Congress 2020, American Society of Civil Engineers.10.1061/9780784482896.006 ↗
2. Progressive collapse fragility of reinforced concrete framed structures through incremental dynamic analysis10.1016/j.engstruct.2015.09.024 ↗
3. Progressive collapse mechanisms of brittle and ductile framed structures10.1061/(ASCE)EM.1943-7889.0000143 ↗
4. Fire induced progressive collapse of steel building structures: The role of interior gravity columns10.1016/j.engstruct.2013.09.020 ↗
5. Design of steel moment frames considering progressive collapse10.12989/scs.2008.8.1.085 ↗
6. Cassiano1a, D., D’Aniello, M., Rebelo, C., Landolfo, R., and da Silva, L.S. (2016). Influence of seismic design rules on the robustness of steel moment resisting frames. Steel Compos. Struct., 21, 479–500.10.12989/scs.2016.21.3.479 ↗
7. Dynamic increase factor for progressive collapse analysis of semi-rigid steel frames
8. A review of progressive collapse research and regulations10.1680/stbu.12.00023 ↗
9. Gsa, U. (2003). Progressive Collapse Analysis and Design Guidelines for New Federaloffice Buildings and Major Modernization Projects, The US General ServicesAdministration.
10. Department of Defense (2020, July 18). Design of Buildings to Resist Progressive Collapse; Unified Facilities Criteria (UFC)-DoD. Available online: https://www.wbdg.org/FFC/DOD/UFC/ARCHIVES/ufc_4_023_03_2009_c2.pdf.
11. Progressive collapse behaviour of steel framed substructures with various beam-column connections10.1016/j.engfailanal.2020.104399 ↗
12. Experimental Tests of Steel Frames with Different Beam–Column Connections under Falling Debris Impact10.1061/(ASCE)ST.1943-541X.0002469 ↗
13. Investigation of different steel intermediate moment frame connections under column-loss scenario10.1016/j.tws.2020.106875 ↗
14. Structural performance of semi-rigid composite frame under column loss10.1016/j.engstruct.2015.03.049 ↗
15. Zhang, J., Jiang, J., Xu, S., and Wang, Z. (2018). An investigation of the effect of semi-rigid connections on sudden column removal in steel frames. Structures, Elsevier.10.1016/j.istruc.2017.12.001 ↗
16. Disproportionate collapse performance of partially restrained steel frames with bolted T-stub connections10.1016/j.engstruct.2010.09.015 ↗
17. Experimental testing and numerical modelling of steel moment-frame connections under column loss10.1016/j.engstruct.2017.08.068 ↗
18. Cap truss and steel strut to resist progressive collapse in RC frame structures
19. Component-based steel beam–column connections modelling for dynamic progressive collapse analysis10.1016/j.jcsr.2015.01.001 ↗
20. Efficient progressive collapse analysis for robustness evaluation of buildings experiencing column removal10.1016/j.jcsr.2016.04.010 ↗
21. Experimental study of through diaphragm connection types under a column removal scenario10.1016/j.jcsr.2015.05.022 ↗
22. Seismic and Progressive Collapse Assessment of New Proposed Steel Connection10.1260/1369-4332.18.3.439 ↗
23. A basis for comparing progressive collapse resistance of moment frames and connections10.1016/j.jcsr.2017.09.007 ↗
24. Study of the mechanics of progressive collapse with simplified beam models10.1016/j.engstruct.2016.02.056 ↗
25. Effects of span-to-depth ratios on moment connection damage evolution under catenary action10.1016/j.jcsr.2017.09.011 ↗
26. Rezvani, F.H., Yousefi, A.M., and Ronagh, H.R. (2015). Effect of span length on progressive collapse behaviour of steel moment resisting frames. Structures, Elsevier.
27. Progressive failure modelling and ductility demand of steel beam-to-column connections in fire10.1016/j.engstruct.2015.01.053 ↗
28. Resistance and Response of Steel and Steel–Concrete Composite Structures in Progressive Collapse Assessment10.2749/101686612X13216060213392 ↗
29. Behaviour of open beam-to-tubular column angle connections under combined loading conditions10.12989/scs.2014.16.2.157 ↗
30. Application of acoustic emission for damage classification and assessment of corrosion in pre-stressed concrete pipes10.1016/j.measurement.2020.107855 ↗
31. On the progressive collapse resistant optimal seismic design of steel frames10.12989/sem.2016.60.5.761 ↗
32. Influence of seismicity level and height of the building on progressive collapse resistance of steel frames10.1002/tal.1305 ↗
33. Rate-Dependent Progressive Collapse Resistance of Beam-to-Column Connections with Different Seismic Details10.1061/(ASCE)CF.1943-5509.0000922 ↗
34. Robustness of Bolted-Angle Connections against Progressive Collapse: Experimental Tests of Beam-Column Joints and Development of Component-Based Models10.1061/(ASCE)ST.1943-541X.0000749 ↗
35. Jamshidi, A., Koduru, S., and Driver, R.G. (2014). Reliability Analysis of Shear Tab Connections under Progressive Collapse Scenario. Structures Congress 2014, ASCE.10.1061/9780784413357.189 ↗
36. 3D Limit Analysis of Progressive Collapse in Partly Weathered Hoek–Brown Rock Banks10.1061/(ASCE)GM.1943-5622.0000885 ↗
37. Shear connection modelling for column removal analysis10.1016/j.jcsr.2015.10.015 ↗
38. Hysteresis model of bolted-angle connections10.1016/S0143-974X(99)00070-X ↗
39. Stylianidis, P.M., Nethercot, D.A., Izzuddin, B.A., and Elghazouli, A.Y. (2009). Progressive collapse: Failure criteria used in engineering analysis. Structures Congress 2009: Don’t Mess with Structural Engineers: Expanding Our Role, ASCE.10.1061/41031(341)200 ↗
40. (2010). Seismic Provisions for Structural Steel Buildings, American Institute of Steel Construction.
41. Performance of different stiffness connections against progressive collapse10.1016/j.jcsr.2017.04.021 ↗
42. Seismic and progressive collapse assessment of SidePlate moment connection system10.12989/sem.2015.54.1.035 ↗
43. Performance of practical beam-to-SHS column connections against progressive collapse10.1016/j.engstruct.2015.10.040 ↗
44. Experimental tests of different types of bolted steel beam–column joints under a central-column-removal scenario10.1016/j.engstruct.2013.03.037 ↗
45. Mckay, A., Gomez, M., and Marchand, K. (2010). Non-Linear Dynamic Alternate Path Analysis for Progressive Collapse: Detailed Procedures Using UFC 4-023-03, Protection Engineering Consultants. (Revised July 2009).
46. Pekelnicky, R., Engineers, S.D., Poland, S.C., and Engineers, N.D. (2012, January 12–15). Seismic Evaluation and Retrofit Rehabilitation of Existing Buildings. Proceedings of the SEAOC, Santa Fe, NM, USA.
47. Behaviour of shear tab connections in column removal scenario10.1016/j.jcsr.2017.08.010 ↗
48. Seismic performance of bolted connection of H-beam to HSS-column with web end-plate10.1016/j.jcsr.2019.01.024 ↗
49. Effect of weld metal toughness on fracture behavior under ultra-low cycle fatigue loading (earthquake)10.1016/j.msea.2016.03.086 ↗