journal article·2020-01-16Open access

Effects of Parameters of Air-Avid Structure on the Salt-Frost Durability of Hardened Concrete

Hui Zhang, Peiwei Gao, Zhixiang Zhang, Youqiang Pan, Weiguang Zhang

Applied Sciences· Volume 10· Issue 2

Abstract

Through laboratory testing, this research studied the connection between air-void structures of hardened concrete and fresh concrete and discussed the effects of the air-void structure on the salt-frost durability of the concrete. The results demonstrate that, in comparison with fresh concrete, the air-void spacing factor shows a close correlation with hardened concrete air-content and decreases in the form of a power function as the air-content increases. When the fresh concrete air-content is more than 6% and the hardened concrete air-void spacing factor is less than 0.18 mm, the influence of parameters of air-void structure on the salt-frost resistance of the concrete reduces. The air-void spacing factor more significantly affects the salt-frost resistance of the concrete compared with air content and the correlation reaches 0.93. Therefore, air-content and air-void spacing factor are recommended for dual control.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Concrete and Cement Materials Research · Innovative concrete reinforcement materials · Concrete Properties and Behavior

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

College of Civilaviation, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China

Jiangsu SinoRoad Engineering Research Institute, Nanjing 211806, China

School of Transportation, Southeast University, Nanjing 211189, China

Funding

Jiangsu Natural Science Foundation (Youth Fund) · Jiangsu Natural Science Foundation (Surface Project) · High-level Talent Project Funding Scheme of Jiangsu · Post-doctoral fund of China · project of traffic construction in Shanxi Province

References (16)

Show source-provided references
1. Tan, W., Wang, D., and Ding, J. (2008). Concrete Microstructure, Properties and Materials, Power Press.
2. Theory of volume change in hardened Portland cement pastes during freezing
3. Mechanisms of air entrainment in concrete10.1016/j.cemconres.2004.07.026 ↗
4. Fagerlund, G. (1997). Scaling, freezing absorption and dilation of cement mortars exposed to Freezing and thawing in NaCl solution. Freeze-Thaw of Concrete, E&FN Spon.
5. Analysis on the air-void system test methods of concrete
6. Air void system and frost-salt scalingof concrete containing slag-blended cement10.1016/j.conbuildmat.2008.10.001 ↗
7. Effect of Air Void Parameters on Properties of Air Entraining Concrete
8. Effect of Air-entraining Admixtures on the Structure and Properties of Hardened Concrete
9. Hazrati, K., Abesque, C., and Pigeon, M. (1993, January 30–31). Efficiency of sealers to prevent the deicer salt scaling resistance of concrete. Proceedings of the International Workshop on the Resistance of Concrete to Freezing in the Presence of Deicing Salts, Quebec, QC, Canada.
10. Frost resistant concrete10.1016/0950-0618(95)00067-4 ↗
11. Influence Factors of Frost-Salt Resistance of Cement Concrete
12. Freezeing-thaw and decing salt resistance of concrete testing by CDF method, CDF resistance limit and evaluationof precision10.1007/BF02473288 ↗
13. Effects of surface states on salt-frost scaling resistance of cement concrete
14. Influence of Chloride Solution Concentration Difference on Salt Frost Scaling of Concrete
15. Effects of water-binder ratio and gas content on the frost-salt resistant ability of concrete
16. Study on Salt-freeze Resistance of Bridge Deck Concrete in Alpine Region