Environmental Effects on HV Dielectric Materials and Related Sensing Technologies
Source abstract
Abstract
The increase in recent power failures, with negative impacts on humans and the economy, has been largely attributed to environmental effects and the aging of the power network. These have been accelerated in the last years due to two main factors: an increased load on the power network and material degradation owing to the presence of environmental pollutants. These factors together with specific weather conditions create the incipient conditions for power network degradation. In this paper, a review of the influence of environmental factors on high-voltage (HV) materials and components is provided. Sensing and artificial intelligence (AI) technologies developed to prevent the failure of the material structure and HV components are also reported.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: High voltage insulation and dielectric phenomena · Power Transformer Diagnostics and Insulation · Electrical Fault Detection and Protection
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Centre for Technology Innovation, IntAIB, Melbourne 3136, Australia
Department of Electronics and Communication Engineering, ASET, Amity University, Noida, Uttar Pradesh 201313, India
Institute for Tropical Technology, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet street, Cau Giay district, Hanoi, Vietnam
School of Engineering, RMIT University, GPO Box 2476, Melbourne, Victoria 3001, Australia
References (100+)
Show source-provided references
1. Jones, R. (2019, January 09). An Incomplete History and Timeline of Electric Telegraph and CD 731 Compromise Insulator, Hamilton, Ohio. Available online: https://www.insulators.info/shows/handouts/cd_731.pdf.
2. Tod, J.H. (2019, January 29). A history of Electrical Porcelain Industry in the United States; Printed privately by Jack H. Todd. Available online: https://www.r-infinity.com/ebay/Electrical_Porcelain/Electrical_Porcelain_Adobe.pdf.
3. The comparison of ceramic and non-ceramic insulators
4. History and biography of polymeric insulators for outdoor applications10.1109/61.180359 ↗
5. The mechanism of the contamination of porcelain insulators
6. Effect of pollution on high-voltage outdoor insulators
7. In-service aging and degradation of 345 kV EPDM transmission line insulators in a coastal environment10.1109/TDEI.2004.1285906 ↗
8. Hussain, M., Farokhi, S., McMeekin, S.G., and Farzaneh, M. (2015, January 18–21). Dry Band Formation on HV Insulators polluted with Different Salt Mixtures. Proceedings of the Annual Conference on Electrical Insulation and Dielectric Phenomena, Ann Arbor, MI, USA.10.1109/CEIDP.2015.7352000 ↗
9. El-Amine, M.S., Hadi, H., and Flazi, S. (2008, January 26–29). Investigation on Influence of Salts Mixture on the Determination of Flashover Discharge Constant Part I: A Preliminary Study. Proceedings of the IEEE Conference on Electrical Insulation and Dielectric Phenomena, Quebec, QC, Canada.
10. Effect of nonuniform pollution on the withstand characteristics of extra high voltage suspension ceramic insulator string10.1049/iet-gtd.2009.0387 ↗
11. Performance of insulators for direct current transmission line under polluted condition
12. Improvement of the dc voltage insulation efficiency of suspension insulators under contaminated conditions10.1109/14.16529 ↗
13. Natural pollution test of insulators energized with HVDC10.1109/TPAS.1974.293987 ↗
14. Performance of Insulators for direct current transmission line under polluted condition10.1109/TPAS.1973.293660 ↗
15. Prediction of flashover voltage of non-ceramic insulators under contaminated conditions10.1109/TDEI.2006.1667747 ↗
16. Impact of weathering on flashover performance of nonceramic insulators10.1109/TDEI.2008.4591230 ↗
17. Mechanism of contaminant accumulation and flashover of insulator in heavily polluted coastal area10.1109/TDEI.2010.5595568 ↗
18. Particle contamination of high voltage DC insulators below corona threshold10.1109/TEI.1979.298185 ↗
19. Long-term tests of insulators under natural pollution condition at the big eddy test center10.1109/61.19211 ↗
20. Experimental investigation on outdoor insulation for DC transmission line at high altitudes10.1109/TPWRD.2009.2034889 ↗
21. (1995). IEEE Standard Techniques for High Voltage Testing, IEEE. (Std. 4–1987).
22. Mechanism of saline deposition and surface flashover on outdoor insulators near coastal areas part II: Impact of various environment stresses10.1109/TDEI.2017.006386 ↗
23. Effect of the combined pollution of brick industry and sandstorms on the performance of high voltage insulators
24. Effect of desert environmental conditions on the flashover voltage of insulators10.1016/S0196-8904(01)00174-1 ↗
25. A study of pollution effect on flashover phenomenon for south-west Iraqi (132kV) grid insulators
26. Challagondla, N.K. (2015). Behaviour of Water Drop on the Insulator Surface and Study of Electric Field Distribution on Parallel Insulators Under DC. [Ph.D. Thesis, Brandenburg University of Technology].
27. Effect of environment pollution on the performance of power transmission lines: Insulator’s flashover
28. Effect of environment desert conditions on the performance of hydrophobic polymer insulator surfaces
29. Performance of high-voltage polymeric insulators under simulated environmental conditions in desert areas of Southern Libya10.1007/s42341-018-0007-y ↗
30. Generating Infrastructural invisibility: Insulation, interconnection, and avian excrement in the Southern California power grid10.1215/22011919-3615916 ↗
31. Izadi, M., Rahman, M.S.A., Ab-Kadir, M.Z.A., Gomes, C., Jasni, J., and Hajikhani, M. (2017). The influence of lightning induced voltage on the distribution power line polymer insulators. PLoS ONE, 12.10.1371/journal.pone.0172118 ↗
32. Surface discharge initiated by immobilized metallic particles attached to gas insulated substation insulators: Process and features10.1109/TDEI.2011.5931067 ↗
33. Effect of fog-haze on AC flashover performance of insulator
34. Effects of haze environment on discharge path under lightning impulses
35. Simulation method and testing apparatus of fog-haze
36. Adhesion force and long-range attractive force between contamination particles and insulator surface
37. Insulator pollution in transmission lines10.24084/repqj04.256 ↗
38. International Electrotechnical Commission (2008). Selection and Dimensioning of High-Voltage Insulators Intended for Use in Polluted Conditions—Part 1: Definitions, Information and General Principles, IEC TS 60815-1:2008.
39. Nogol, O. (1990). High Voltage Insulators Constructed to Have Plural Dry Bands in Use. (4,891,473), U.S. Patent.
40. Behaviour of AC high voltage polyamide insulators: Evolution of leakage current in different surface conditions
41. Effect of pollution severity and dry band location on the flashover characteristics of silicone rubber surfaces10.1007/s00202-016-0473-3 ↗
42. Assessment of the risk of failure of high voltage substations due to environmental conditions and pollution on insulators
43. Imhof, A. (1960). High Voltage Insulator. (2945912A), U.S. Patent.
44. Denholm, A.S. (1964). High-Voltage Electrical Insulating Bushing. (3126439A), U.S. Patent.
45. Talcott, D.T. (1970). Weatherable Electrical Insulators made of Thermosetting Resin. (US 3,511,698), U.S. Patent.
46. Mitsumatsu, Y., and Seike, S. (1987). High Voltage Porcelain Insulators. (EP0119838B1), Patent.
47. Niemi, R.G. (1970). Method of Improving A High Voltage Insulator and Suitable Composition. (EP0123487B1), Patent.
48. Amarasekera, J., and Doin, J.E. (1999). Silicone Compositions for High Voltage Insulator Applications. (EP0 928008A2), Patent.
49. Phillips, A.J., Birrell, D.S., and Childs, D.J. (1998). Aging Resistant, High Voltage Non-Ceramic Insulation. (5,792,996), Patent.
50. Greyling, C.J. (2010). Polymeric High Voltage Insulator with a Hard, Hydrophobic Surface. (2010/0326699 A1), U.S. Patent.
51. Chisholm, W., and Farzaneh, M. (2009). Environmental Exposure of Insulators for Icing and Polluted Environments, Wiley–IEEE Press.10.1002/9780470496251 ↗
52. Niemi, R.G. (1984). High Voltage Insulators. (4476155A), U.S. Patent.
53. Becker, K. (2012). Conductive Contamination Resistant Insulator. (US 2010/0108915 A1), U.S. Patent.
54. Li, J., Fan, L., Wong, C.-P., and Lambert, F.C. (2010). Insulator Coating and Method for Forming Same. (7,722,951 B2), U.S. Patent.
55. Degradation and stability of polymeric high-voltage insulators and prediction of their service life through environmental and accelerated aging processes10.1021/acsomega.8b01560 ↗
56. Narain, G.H. (1991). Aparatus for Washing Electrical Insulators. (5,041,164A), U.S. Patent.
57. Meguriya, N., Azechi, S., Sekiguchi, S., and Yoshida, T. (2000). Silicone Rubber Compositions for High-Voltage Electrical Insulators and Polymeric Bushings. (6,106,954A), U.S. Patent.
58. Richards, C.N. (2001). Semiconductive Attachment Disc for Insulators to Reduce Electrical Stress Induced Corrosion. (6,265,669 B1), U.S. Patent.
59. Aging Investigations of Polymeric Insulators: Overview and Bibliography10.1109/MEI.2007.386482 ↗
60. Peek, F.W. (1929). Dielectric Phenomena in High Voltage Engineering, McGraw-Hill. [3rd ed.].
61. A study of electromagnetic radiation of corona discharge near 500-Kv electric installations
62. Practical cases of electric field distribution along dry and clean nonceramic insulators of high voltage power lines10.1109/TPWRD.2007.893190 ↗
63. Anomalous aging phenomena in a crosslinked polyolefin cable insulation10.1016/0969-806X(93)90026-Q ↗
64. Computation of three-dimensional electric field problems and its application to optimum insulator design10.1109/TPAS.1982.317276 ↗
65. Potential and electric field distribution at a HV insulator shed
66. Electric potential and field along ac HV insulators10.1109/94.368665 ↗
67. Electrical and thermal analysis of polymer insulator under contaminated surface conditions10.1109/94.486781 ↗
68. Measurement and simulation of the electric field of high voltage suspension insulators10.1002/etep.238 ↗
69. Impact of electromagnetic radiation on cascaded failure in high voltage insulators10.1063/1.3551544 ↗
70. Stability of alternating current discharges between water drops on insulation surfaces10.1088/0022-3727/39/14/029 ↗
71. Electrohydrodynmaic behaviour of water droplet on an electrically stressed hydrophobic surface10.1088/0022-3727/39/9/038 ↗
72. Resonance phenomena of single water droplet located on a hydrophobic sheet under AC electric field10.1109/TIA.2002.807232 ↗
73. Higashiyama, Y., and Kamada, M. (2017, January 13–15). Dehumidification using negative corona discharge from a water droplet. Proceedings of the Annual Meeting of the Electrostatics of America, Ottawa, ON, Canada.
74. Hinde, D.D. (2009). Corona discharges on the surfaces of high voltage composite insulators. [Ph.D. Thesis, Queensland University of Technology].
75. Instability of electrified liquid surfaces10.1103/PhysRev.10.1 ↗
76. Disintegration of water drops in an electric field10.1098/rspa.1964.0151 ↗
77. Positive and negative point-to-plane corona in air10.1103/PhysRev.74.179 ↗
78. The influence of hanging water droplets on discharge activity, application to high voltage insulators10.1063/1.3559850 ↗
79. Kreuger, F.H. (1989). Partial Discharge Detection in High Voltage Equipment, Butterworths.
80. Measurement and simulation of pd in epoxy voids10.1109/94.469970 ↗
81. Electron avalanches I. Statistics of partial microdischarges in their pre-streamer stage10.1109/TDEI.2003.1219654 ↗
82. Electron avalanches II. Fractal morphology of partial microdischarge spots on dielectric barriers10.1109/TDEI.2003.1219655 ↗
83. Detection of wide-band E-M signals emitted from partial discharge occurring in GIS using wavelet transform10.1109/61.852970 ↗
84. Application of very-high-frequency (VHF) method to ceramic insulators10.1109/TDEI.2004.1387829 ↗
85. Oughstun, K.E., and Sherman, G.C. (2002). Electromagnetic Pulse Propagation in Causal Dielectrics, Springer.
86. Locating partial discharge source occurring on distribution line by using FDTD and TDOA methods10.1541/ieejfms.129.89 ↗
87. Bojovschi, A., Rowe, W.S.T., and Wong, K.L. (, January 27–30). Radiation Spectra of Partial Discharge in Dielectrics. Proceedings of the 19th Australian Universities Power Engineering Conference, Adelaide, Australia.
88. Wong, K.L. (2007). Method and Apparatus for Detecting an Event. (WO 2007070942), Patent.
89. Bojovschi, A., Rowe, W.S.T., and Wong, K.L. (2009, January 24–28). Dynamcis of Partial Discharge in Dielectrics: A Computational Approach. Proceedings of the 16th International Symposium on High Voltage Engineering, Cape Town, South Africa.
90. Electromagnetic field intensity generated by partial discharge in high voltage insulating materials10.2528/PIER10010803 ↗
91. Smith, P.S. (2001). Device for Locating and Detecting Insulator Defects. (20010052778A1), U.S. Patent.
92. Domingues, E.D. (2012). S Improved Condition Monitoring of Composite Insulators. [Ph.D. Thesis, University of Manchester].
93. Kloes, H., and Koenig, D. (1996, January 16–19). Multifactor-Surface-Tests of Organic Insulating Materials in the Early Stage of Degradation. Proceedings of the IEEE International Symposium on Electrical Insulation, Montreal, QB, Canada.
94. Asset management for transmission and distribution10.1109/MPAE.2005.1436499 ↗
95. A reliability-centered asset maintenance method for assessing the impact of maintenance in power distribution systems10.1109/TPWRS.2004.840433 ↗
96. Diagnostic methods for outdoor polymeric insulators10.1109/TDEI.2007.4339466 ↗
97. Online hydrophobicity measurement for silicone rubber insulators on transmission lines10.1109/TPWRD.2008.2005654 ↗
98. Characterization of polymeric insulators using thermal and UV imaging under laboratory conditions10.1109/TDEI.2009.5211844 ↗
99. Detecting defects in outdoor non-ceramic insulators using near-field microwave non-destructive testing10.1109/TDEI.2010.5448094 ↗
100. Investigations on leakage current and phase angle characteristics of porcelain and polymeric insulator under contaminated conditions10.1109/TDEI.2009.4815193 ↗