Abstract

Although dual-threaded pedicle screws have been developed, the advantages over single-threaded screws remain controversial. We aimed to investigate the biomechanical performance of two types of dual-threaded pedicle screw by comparing their pullout strength with that of a single-threaded screw in relation to bone quality. Four types of pedicle screw with different thread patterns were designed. Type I: single-threaded screw; Type II: double-threaded screw; Type III: dual-threaded screw; Type IV: a newly designed double dual-threaded screw. Five types of polyurethane foams simulating various degrees of bone quality were used. These were: Type A: cancellous bone; Type B: cancellous bone with cortical bone in the upper margin; Type C: osteoporotic cancellous bone; Type D: osteoporotic cancellous bone with cortical bone in the upper margin; and Type E: osteoporotic bone with cortical bone in the upper and lower margins. A comparison of the pullout strength of Type I, II, and III screws in Type A, B, C and D bone specimens was performed. Type C and E bone specimens were used for comparisons among Type I, II, and IV screws. Compared to the single-threaded screw, the dual-threaded pedicle screws exhibited higher pullout strength in normal-quality bone and significantly lower pullout strength in compromised osteoporotic bone. However, the double dual-threaded screw exhibited better pullout biomechanics in osteoporotic bone with bi-cortical bone.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Spinal Fractures and Fixation Techniques · Spine and Intervertebral Disc Pathology · Hip and Femur Fractures

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Spine Center and Department of Orthopedic Surgery, Seoul National University College of Medicine and Seoul National University Bundang Hospital, 166 Gumiro, Bundang-gu, Sungnam 463-707, Korea

Department of Mechanical Engineering, Yonsei University, 134 Shinchon-dong, Seodaemun-gu, Seoul 100-011, Korea

Funding

National Research Foundation of Korea

References (26)

Show source-provided references
1. Accuracy of pedicular screw placement in vivo10.1097/00007632-199001000-00004 ↗
2. Weinstein, J.N., Rydevik, B.L., and Rauschning, W. (1992). Anatomic and technical considerations of pedicle screw fixation. Clin. Orthop. Relat. Res., 34–46.10.1097/00003086-199211000-00006 ↗
3. Interbody fusion and instrumentation10.1097/00003086-199403000-00011 ↗
4. Low Back Pain: Current Surgical Approaches10.4184/asj.2015.9.4.645 ↗
5. Increase of pullout strength of spinal pedicle screws with conical core: Biomechanical tests and finite element analyses10.1016/j.orthres.2004.11.002 ↗
6. Comparative Analysis of Effect of Density, Insertion Angle and Reinsertion on Pull-Out Strength of Single and Two Pedicle Screw Constructs Using Synthetic Bone Model10.4184/asj.2016.10.3.414 ↗
7. Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?10.1016/j.spinee.2003.12.004 ↗
8. Ibrahim, H., Jahadakbar, A., Dehghan, A., Moghaddam, N.S., Amerinatanzi, A., and Elahinia, M. (2018). In vitro corrosion assessment of additively manufactured porous NiTi structures for bone fixation applications. Metals, 8.10.3390/met8030164 ↗
9. On the Ni-ion release rate from surfaces of binary NiTi shape memory alloys10.1016/j.apsusc.2017.08.235 ↗
10. Influence of PVD-coating technology and pretreatments on residual stresses for sheet-bulk metal forming tools10.1007/s11740-015-0653-4 ↗
11. Pedicle screws with a thin hydroxyapatite coating for improving fixation at the bone-implant interface in the osteoporotic spine: Experimental study in a porcine model10.3171/2017.10.SPINE17702 ↗
12. Improving corrosion resistance of additively manufactured nickel–titanium biomedical devices by micro-arc oxidation process10.1007/s10853-019-03375-1 ↗
13. Designs and techniques that improve the pullout strength of pedicle screws in osteoporotic vertebrae: Current status10.1155/2014/748393 ↗
14. Minimizing pedicle screw pullout risks: A detailed biomechanical analysis of screw design and placement10.1097/BSD.0000000000000151 ↗
15. Characteristics of immediate and fatigue strength of a dual-threaded pedicle screw in cadaveric spines10.1016/j.spinee.2013.03.010 ↗
16. ASTM International (2001). Standard Specification for Rigid Polyurethane Foam for Use as a Standard Material for Testing Orthopedic Devices and Instrument, ASTM International. ASTM F1839-01.
17. Assessment of pedicle screw pullout strength based on various screw designs and bone densities-an ex vivo biomechanical study10.1016/j.spinee.2012.01.014 ↗
18. ASTM International (2013). Standard Specification and Test Methods for Metallic Medical Bone Screws, ASTM International. ASTM F543-13.
19. Characteristics of pullout failure in conical and cylindrical pedicle screws after full insertion and back-out10.1016/S1529-9430(01)00119-X ↗
20. Triangulated pedicle screw construct technique and pull-out strength of conical and cylindrical screws10.1097/00002517-200108000-00007 ↗
21. Factors affecting the pullout strength of cancellous bone screws10.1115/1.2796022 ↗
22. Pedicle screw fixation strength: Pullout versus insertional torque10.1016/j.spinee.2004.02.006 ↗
23. Influence of thread design on pedicle screw fixation. Laboratory investigation10.3171/SPI/2008/9/7/090 ↗
24. Cortical bone trajectory for lumbar pedicle screws10.1016/j.spinee.2008.07.008 ↗
25. Sol-gel process applications: A mini-review10.11605/j.pnrs.201802008 ↗
26. Ultrasound melted polymer sleeve for improved primary pedicle screw anchorage: A novel augmentation technique10.1016/j.clinbiomech.2019.02.007 ↗